1. Home /
  2. Catalog /
  3. Switches /
  4. 5930-00-880-4790

5930-00-880-4790

Find complete technical information, availability, and procurement data for: 5930-00-880-4790

DODParts.com distributes related products varnishes dopes paints, aircraft parts and consumables, electrical parts, fittings and other components for the aerospace and defense industries. Submit the short price quote form for NSN 5930-00-880-4790 to receive an up to date pricing and availability quote by email.

5930-00-880-4790
Federal Supply Group
Electrical and Electronic Equipment Components
Federal Supply Classification
5930 Switches
National Stock Number
5930-00-880-4790
Item Name Code
00184
Assigment Date
01/01/1960 (66 years ago)

0.670 inches maximum overall length, bushing mount body style, submersible hazardous locations/environmental protection, 1.930 inches nominal overall height, 2a and 2b thread class

Product Characteristics

Below you’ll find the complete technical specifications and performance data for this part, including material details and compliance information.

Thread Class
2a and 2b
Body Style
bushing mount
Hazardous Locations/Environmental Protection
submersible
Overall Length
0.670 inches maximum
Overall Height
1.930 inches nominal
Overall Width
0.670 inches maximum
Bushing Length
0.170 inches nominal
Body Length
0.670 inches maximum
Body Width
0.670 inches maximum
Actuator Style
round
Actuator Diameter
0.093 inches nominal
Actuator Height
0.440 inches nominal
Actuator Position-Action Relationship
up position maintained and down position maintained
Maximum Voltage Rating In Volts
115.0 ac and 28.0 dc
Mounting Surface To Terminal End Distance
1.320 inches maximum
Inclosure Type
fully inclosed
Mounting Method
threaded bushing
Features Provided
actuator seal
Thread Quantity Per Inch
40
Nominal Thread Size
0.250 inches
Nonpile-Up Contact Arrangement
2 pole, single throw, both positions maintained single switch unit
Contact Load Current Rating At Maximum Rated Voltage
5.000 amperes resistive dc and 1.000 amperes inductive dc and 3.000 amperes resistive ac and 2.000 amperes inductive ac
Precious Material And Location
terminal surfaces gold
Test Data Document
"81349-mil-s-8834 specification (includes engineering type bulletins, brochures,etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type data on certain environmental and performance requirements and test conditions that are shown as "typical", "average", "nominal", etc.)."
Thread Series Designator
uns
Terminal Type And Quantity
4 tab, solder lug
Specification/Standard Data
96906-ms24656 government standard

Replaces National Stock Numbers

Below is a list of NSNs that have been officially superseded by this NSN:

NSN Name Date
5930-00-897-9966 No Name Available 02/01/1998
5930-00-997-8183 No Name Available 04/01/2008

Related Parts

This NSN group includes multiple components designed to meet specific performance and operational standards. Each listing provides detailed specs, functionality data, and replacement compatibility information:

Part Number Name
2396466G2 Toggle Switch
2504777-221 Toggle Switch
266-5043-000 Toggle Switch
7902817-01 Toggle Switch
8877K14 Toggle Switch
908084 Toggle Switch
MS24646-221 Toggle Switch
MS24656-221 Toggle Switch

FAQs

Find helpful answers about installation, operation, maintenance, compliance, and troubleshooting.

What is the FSCG of the NSN 5930-00-880-4790?
The FSCG of the NSN 5930-00-880-4790 is 5930
Does the NSN 5930-00-880-4790 have a Schedule B code assigned?
Yes, the Schedule B code is 8536509065
Does NSN 5930-00-880-4790 require demilitarization?
Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.
Does NSN 5930-00-880-4790 contain precious materials?
Item contains gold.
Does NSN 5930-00-880-4790 contain hazardous materials?
Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
When the NSN 5930-00-880-4790 was assigned to the Federal Catalog?
It was assigned 66 years ago, on Fri, Jan 1, 1960

Professional Distribution

Certified to meet the strict requirements of defense, aerospace, and hazardous materials distribution.

  • ITAR Registered
  • DDTC Registered
  • HAZMAT Certified
  • AS9120 Quality Standards
  • 100% Quality Inspections

You May Also Like

Browse other in-demand NSN parts sourced by professionals in defense, aerospace, and manufacturing sectors. Each component meets strict standards for quality and performance.

Pricing

Submit your request below and our team will respond quickly with up-to-date pricing, delivery estimates, and stock information:

ITAR Registered

Featured Parts

Explore our most requested parts, carefully selected based on customer demand and sourcing activity. Each listing provides current specifications, availability status, and item condition:

SSI/5-GREEN
5980-01-374-4684
Light Emitting Diode
SSI-5-RED
5980-01-275-3067
Light Emitting Diode
SSI-50-C-M-1/2
4820-01-200-9346
Check Valve
SSI-68-1
5895-01-419-0145
Communication Equ Interface Unit
SSI-78A207J
5962-01-363-1023
Digital Microcircuit
SSI-97-2127
5895-01-462-6475
Radio Frequency Power Divider
SSI-CS10
5120-01-374-8937
Hand Terminal Crimping Tool
SSI-FRSS-101
6545-01-624-0462
Pre Operative Patient Bag
SSI-FRSS-102
6545-01-624-0603
Pre Operative Bag
SSI-FRSS-103
6545-01-624-0500
Operating Room Team Preparat Bag
SSI-FRSS-104
6545-01-624-0567
Post Operative Pack Bag
SSI-FRSS-105
6545-01-624-0652
Post Operative Patient Bag
SSI-FRSS-106
6545-01-624-1292
Anesthesia Bag
SSI-FRSS-107
6545-01-624-1270
Operating Room Bag
SSI-FRSS-108
6545-01-624-0881
Operating Room Suture Bag