1. Home /
  2. Catalog /
  3. Switches /
  4. 5930-00-841-7514 /
  5. 6-1-1907-19-23

6-1-1907-19-23

View detailed technical data, stock status, and sourcing information for: 6-1-1907-19-23

DODParts.com distributes related products varnishes dopes paints, aircraft parts and consumables, electrical parts, fittings and other components for the aerospace and defense industries. Submit the short price quote form for part 6-1-1907-19-23 to receive an up to date pricing and availability quote by email.

6-1-1907-19-23
Federal Supply Group
Electrical and Electronic Equipment Components
Federal Supply Classification
5930 Switches
National Stock Number
5930-00-841-7514
Item Name Code
00451
Assigment Date
01/01/1962 (64 years ago)

A definite continuous length of cable,power,electrical having one or both ends processed and/or terminated in fittings which provide for connection to other items. The rated working voltage of the item must be 300 volts or more. For items which the rated working voltage is less than 300 volts, see: cable assembly,special purpose,electrical. Excludes: cable and conduit assembly,electrical and items having branches or forks. See also wiring harness.

1a single threaded bushing thread class, 3.530 inches nominal overall diameter, 0.620 inches nominal single threaded bushing thread length, 6.370 inches nominal overall length, 3.625 inches nominal body length

Product Characteristics

Below you’ll find the complete technical specifications and performance data for this part, including material details and compliance information.

Thread Class
1a single threaded bushing
Thread Length
0.620 inches nominal single threaded bushing
Overall Length
6.370 inches nominal
Body Length
3.625 inches nominal
Overall Diameter
3.530 inches nominal
Temp Sensing Element Type
internal sensor
Mounting Method
threaded bushing
Thread Quantity Per Inch
13 single threaded bushing
Contact Action Stimulus
increase
Nominal Thread Size
0.500 inches single threaded bushing
Nonpile-Up Contact Arrangement
1 pole, single throw, normally open, momentary action
Terminal Type
wire lead
Contact Load Current Rating
15.0 amperes resistive load single voltage
Contact Adjustability
actuation point adjustable
Contact Adjustment Range
+50.00 to 300.00 actuation point degrees fahrenheit
Contact Adjustment Type
external actuation point screw
Contact Voltage Rating In Volts
250.0 ac at sea level single voltage
Frequency In Hertz
60.0 single voltage
Media For Which Designed
gas or liquid
Style Designator
cylindrical
Thread Series Designator
npt single threaded bushing

Replaces National Stock Numbers

Below is a list of NSNs that have been officially superseded by this NSN:

NSN Name Date
5930-00-905-9135 No Name Available 08/01/2003

Related Parts

This NSN group includes multiple components designed to meet specific performance and operational standards. Each listing provides detailed specs, functionality data, and replacement compatibility information:

Part Number Name
21100-0 Thermostatic Switch
21102-0-50-300 Thermostatic Switch
21103-0 Thermostatic Switch
6-1-1907-19-23 Thermostatic Switch
721856-002 Thermostatic Switch

FAQs

Find helpful answers about installation, operation, maintenance, compliance, and troubleshooting.

What is the FSCG of the NSN 5930-00-841-7514?
The FSCG of the NSN 5930-00-841-7514 is 5930
Does the NSN 5930-00-841-7514 have a Schedule B code assigned?
Yes, the Schedule B code is 9032100000
Does NSN 5930-00-841-7514 require demilitarization?
Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.
Does NSN 5930-00-841-7514 contain precious materials?
Item does not contain precious metal.
Does NSN 5930-00-841-7514 contain hazardous materials?
Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
When the NSN 5930-00-841-7514 was assigned to the Federal Catalog?
It was assigned 64 years ago, on Mon, Jan 1, 1962

Professional Distribution

Certified to meet the strict requirements of defense, aerospace, and hazardous materials distribution.

  • ITAR Registered
  • DDTC Registered
  • HAZMAT Certified
  • AS9120 Quality Standards
  • 100% Quality Inspections

You May Also Like

Browse other in-demand NSN parts sourced by professionals in defense, aerospace, and manufacturing sectors. Each component meets strict standards for quality and performance.

Pricing

Submit your request below and our team will respond quickly with up-to-date pricing, delivery estimates, and stock information:

ITAR Registered

Featured Parts

Explore our most requested parts, carefully selected based on customer demand and sourcing activity. Each listing provides current specifications, availability status, and item condition:

5M2870-22D4J
6145-01-420-6119
Electrical Power Cable
5M2870-22D5J
6145-01-420-5116
Electrical Special Purpose Cable
5M2870-22D5N
6145-01-420-2995
Electrical Special Purpose Cable
5M2870-22D6J
6145-01-420-5117
Electrical Power Cable
5M2870-22D6N
6145-01-420-1824
Electrical Special Purpose Cable
5M2870-22D7J
6145-01-420-3604
Electrical Power Cable
5M2870-22D7N
6145-01-420-2996
Electrical Special Purpose Cable
5M2870-24D1J
6145-01-420-5115
Electrical Special Purpose Cable
5M2870-24D2J
6145-01-420-0774
Electrical Power Cable
5M2870-24D2N
6145-01-420-2991
Electrical Special Purpose Cable
5M2870-24D3J
6145-01-420-6116
Electrical Power Cable
5M2870-24D3N
6145-01-420-3609
Electrical Special Purpose Cable
5M2870-24D4J
6145-01-420-6120
Electrical Power Cable
5M2870-24D4N
6145-01-420-3610
Electrical Special Purpose Cable
5M2870-24D5J
6145-01-420-6122
Electrical Special Purpose Cable