1. Home /
  2. Catalog /
  3. Switches /
  4. 5930-00-548-4267

5930-00-548-4267

Find complete technical information, availability, and procurement data for: 5930-00-548-4267

DODParts.com distributes related products varnishes dopes paints, aircraft parts and consumables, electrical parts, fittings and other components for the aerospace and defense industries. Submit the short price quote form for NSN 5930-00-548-4267 to receive an up to date pricing and availability quote by email.

5930-00-548-4267
Federal Supply Group
Electrical and Electronic Equipment Components
Federal Supply Classification
5930 Switches
National Stock Number
5930-00-548-4267
Item Name Code
00399
Assigment Date
01/01/1963 (63 years ago)

A switch with a quick-acting mechanism actuated by a highly delicate tactile contact. It may include a timer function. Includes membrane switch. Excludes: switch,flexible; switch,pressure; and switch,thermostatic.

2.000 inches maximum body length, 0.998 inches minimum and 1.002 inches maximum center to center distance between mounting facilities parallel to length, pressure proof hazardous locations/environmental protection, hole mounted body style, 0.703 inches maximum body width

Product Characteristics

Below you’ll find the complete technical specifications and performance data for this part, including material details and compliance information.

Body Style
hole mounted
Hazardous Locations/Environmental Protection
pressure proof
Center To Center Distance Between Mounting Facilities Parallel To Length
0.998 inches minimum and 1.002 inches maximum
Body Length
2.000 inches maximum
Body Width
0.703 inches maximum
Body Height
1.200 inches maximum
Actuator Length
0.907 inches minimum and 0.937 inches maximum
Actuator Style
leaf
Actuator Free Position Height
0.515 inches minimum and 0.545 inches maximum
Maximum Voltage Rating In Volts
115.0 ac and 120.0 dc
End Item Identification
helicopter iroquois uh-1
Inclosure Type
hermetically sealed
Mounting Method
unthreaded hole
Nonpile-Up Contact Arrangement
2 two circuit, double break/double make, one position momentary single switch unit
Switch Release Force
4.0 ounces minimum
Switch Actuating Force
22.0 ounces minimum and 28.0 ounces maximum
Actuator Movement
0.085 pretravel inches maximum
Contact Load Current Rating At Maximum Rated Voltage
1.000 amperes resistive dc and 0.500 amperes inductive dc and 1.000 amperes resistive ac and 1.000 amperes inductive ac
Precious Material And Location
contact surfaces silver
Test Data Document
"81349-mils8805 specification (includes engineering type bulletins, brochures,etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type data on certain environmental and performance requirements and test conditions that are shown as "typical", "average", "nominal", etc.)."
Terminal Type And Quantity
3 screw

Replaces National Stock Numbers

Below is a list of NSNs that have been officially superseded by this NSN:

NSN Name Date
5930-00-323-2082 No Name Available 03/13/1967
5930-00-636-4802 No Name Available 05/09/1966
5930-00-636-4806 No Name Available 07/30/2020
5930-00-875-6603 No Name Available 03/30/1966

Related Parts

This NSN group includes multiple components designed to meet specific performance and operational standards. Each listing provides detailed specs, functionality data, and replacement compatibility information:

Part Number Name
5930PL0649712 Sensitive Switch
MIL-PRF-8805/47 Sensitive Switch
MIL-S-8805/47 Sensitive Switch
MS25011-2 Sensitive Switch
MS25011-4 Sensitive Switch

FAQs

Find helpful answers about installation, operation, maintenance, compliance, and troubleshooting.

What is the FSCG of the NSN 5930-00-548-4267?
The FSCG of the NSN 5930-00-548-4267 is 5930
Does the NSN 5930-00-548-4267 have a Schedule B code assigned?
Yes, the Schedule B code is 8536509050
Does NSN 5930-00-548-4267 require demilitarization?
Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.
Does NSN 5930-00-548-4267 contain precious materials?
Item contains silver.
Does NSN 5930-00-548-4267 contain hazardous materials?
Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
When the NSN 5930-00-548-4267 was assigned to the Federal Catalog?
It was assigned 63 years ago, on Tue, Jan 1, 1963

Professional Distribution

Certified to meet the strict requirements of defense, aerospace, and hazardous materials distribution.

  • ITAR Registered
  • DDTC Registered
  • HAZMAT Certified
  • AS9120 Quality Standards
  • 100% Quality Inspections

You May Also Like

Browse other in-demand NSN parts sourced by professionals in defense, aerospace, and manufacturing sectors. Each component meets strict standards for quality and performance.

Pricing

Submit your request below and our team will respond quickly with up-to-date pricing, delivery estimates, and stock information:

ITAR Registered

Featured Parts

Explore our most requested parts, carefully selected based on customer demand and sourcing activity. Each listing provides current specifications, availability status, and item condition:

19REXXX0441A4CXAXX02
6680-01-279-9578
Diff Fluid Flow Indicating Meter
19REXXX0447A4CXAXX01
6685-00-485-5698
Dial Indicatin Differential Gage
19REXXX0447A4CXAXX02
6685-01-320-6217
Dial Indicatin Differential Gage
19REXXX0447A4CXAXX03
6685-01-320-6217
Dial Indicatin Differential Gage
19REXXX0447A4CXAXX04
6685-00-485-5698
Dial Indicatin Differential Gage
19REXXX0508A4CXAXX01
6685-01-500-9522
Dial Indicatin Differential Gage
19REXXX0508A4CXAXX03
6685-01-500-7234
Dial Indicatin Differential Gage
19REXXX0515A4CXAXX01
6680-00-412-5103
Diff Fluid Flow Indicating Meter
19REXXX0515A4CXAXX02
6685-01-324-5661
Dial Indicatin Differential Gage
19REXXX0515A4CXAXX03
6680-00-412-5103
Diff Fluid Flow Indicating Meter
19REXXX0515A4CXAXX04
6685-01-324-5661
Dial Indicatin Differential Gage
19REXXX0523A4CXAXX01
6680-01-277-5974
Diff Fluid Flow Indicating Meter
19REXXX0523A4CXAXX02
6680-01-277-5974
Diff Fluid Flow Indicating Meter
19REXXX0554A4CXAXX
6685-01-500-7232
Dial Indicatin Differential Gage
19REXXX0554A4CXAXX01
6685-01-500-7232
Dial Indicatin Differential Gage