1. Home /
  2. Catalog /
  3. Switches /
  4. 5930-00-225-2392

5930-00-225-2392

Find complete technical information, availability, and procurement data for: 5930-00-225-2392

DODParts.com distributes related products varnishes dopes paints, aircraft parts and consumables, electrical parts, fittings and other components for the aerospace and defense industries. Submit the short price quote form for NSN 5930-00-225-2392 to receive an up to date pricing and availability quote by email.

5930-00-225-2392
Federal Supply Group
Electrical and Electronic Equipment Components
Federal Supply Classification
5930 Switches
National Stock Number
5930-00-225-2392
Item Name Code
00451
Assigment Date
03/10/1971 (55 years ago)

2.125 inches nominal overall height, 5.750 inches nominal body diameter, 0.219 inches nominal unthreaded mounting hole diameter, dustproof hazardous locations/environmental protection, 10.750 inches nominal overall length

Product Characteristics

Below you’ll find the complete technical specifications and performance data for this part, including material details and compliance information.

Hazardous Locations/Environmental Protection
dustproof
Overall Length
10.750 inches nominal
Overall Height
2.125 inches nominal
Body Diameter
5.750 inches nominal
Unthreaded Mounting Hole Diameter
0.219 inches nominal
Distance Between Mounting Facility Centers
2.000 inches nominal
Capillary Tube Length
144.0 inches nominal
Bulb Length
3.000 inches nominal
Bulb Diameter
0.688 inches nominal
Temp Sensing Element Type
capillary tube-bulb
Operating Temp Rating
120.0 fahrenheit maximum
Mounting Method
bracket and unthreaded hole
Features Provided
hermetically sealed case and tubing end seal connection
Contact Action Stimulus
increase
Mounting Facility Pattern
two position in-line
Nonpile-Up Contact Arrangement
1 pole, single throw, normally closed, momentary action
Terminal Type
screw
Contact Load Current Rating
5.0 amperes resistive load fourth voltage
Contact Load Current Rating
5.0 amperes resistive load second voltage
Contact Load Current Rating
10.0 amperes resistive load first voltage
Contact Load Current Rating
10.0 amperes resistive load third voltage
Contact Adjustability
actuation point adjustable and deactuation point adjustable
Contact Adjustment Range
+0.00 to 75.00 actuation point degrees fahrenheit and +0.00 to 75.00 deactuation point degrees fahrenheit
Contact Adjustment Type
external actuation point knob and external deactuation point knob
Contact Voltage Rating In Volts
115.0 ac at sea level first voltage
Contact Voltage Rating In Volts
115.0 dc at sea level third voltage
Contact Voltage Rating In Volts
230.0 ac at sea level second voltage
Contact Voltage Rating In Volts
230.0 dc at sea level fourth voltage
Media For Which Designed
gas or liquid
Style Designator
cylindrical

Related Parts

This NSN group includes multiple components designed to meet specific performance and operational standards. Each listing provides detailed specs, functionality data, and replacement compatibility information:

Part Number Name
500-0099 Thermostatic Switch
DA35-2 Thermostatic Switch

FAQs

Find helpful answers about installation, operation, maintenance, compliance, and troubleshooting.

What is the FSCG of the NSN 5930-00-225-2392?
The FSCG of the NSN 5930-00-225-2392 is 5930
Does the NSN 5930-00-225-2392 have a Schedule B code assigned?
Yes, the Schedule B code is 9032100000
Does NSN 5930-00-225-2392 require demilitarization?
Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.
Does NSN 5930-00-225-2392 contain precious materials?
Precious metal content is unknown
Does NSN 5930-00-225-2392 contain hazardous materials?
Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
When the NSN 5930-00-225-2392 was assigned to the Federal Catalog?
It was assigned 55 years ago, on Wed, Mar 10, 1971

Professional Distribution

Certified to meet the strict requirements of defense, aerospace, and hazardous materials distribution.

  • ITAR Registered
  • DDTC Registered
  • HAZMAT Certified
  • AS9120 Quality Standards
  • 100% Quality Inspections

You May Also Like

Browse other in-demand NSN parts sourced by professionals in defense, aerospace, and manufacturing sectors. Each component meets strict standards for quality and performance.

Pricing

Submit your request below and our team will respond quickly with up-to-date pricing, delivery estimates, and stock information:

ITAR Registered

Featured Parts

Explore our most requested parts, carefully selected based on customer demand and sourcing activity. Each listing provides current specifications, availability status, and item condition:

ITB4102RMB-22-22SCRA
5935-01-678-5869
Electrical Receptacle Connector
ITB4102RMB16-10SCRA
5935-01-678-5842
Electrical Receptacle Connector
ITB4102RMB32-1PB7
5935-01-666-0319
Electrical Receptacle Connector
ITB4102RMB32-5PB7
5935-01-666-4711
Electrical Receptacle Connector
ITB4102RMB32-5SB7
5935-01-666-0085
Electrical Receptacle Connector
ITBI2
5930-00-669-8139
Sensitive Switch
ITBX 11-7529-16
5120-00-022-9803
Contact Insertion Tool Tip
ITBX 1104
5120-01-184-5749
Electrical Contact Inserter
ITBX 1105
5120-01-184-5750
Electrical Contact Inserter
ITBX10
5970-00-851-3638
Electrical Insulation Sleeving
ITBX11-3675
5120-00-091-6753
Electrical Contact Inserter
ITBX11-6781
5120-00-765-3690
Electrical Contact Inserter
ITBX11-6782
5120-00-765-3689
Electrical Contact Inserter
ITBX11-7082
5120-00-991-3928
Electrical Contact Inserter
ITBX11-7345
5120-00-987-7239
Electrical Contact Inserter