1. Home /
  2. Catalog /
  3. Resistor /
  4. 5905-00-615-9381

5905-00-615-9381

Find complete technical information, availability, and procurement data for: 5905-00-615-9381

DODParts.com distributes related products varnishes dopes paints, aircraft parts and consumables, electrical parts, fittings and other components for the aerospace and defense industries. Submit the short price quote form for NSN 5905-00-615-9381 to receive an up to date pricing and availability quote by email.

5905-00-615-9381
Federal Supply Group
Electrical and Electronic Equipment Components
Federal Supply Classification
5905 Resistor
National Stock Number
5905-00-615-9381
Item Name Code
37406
Assigment Date
01/01/1963 (63 years ago)

A resistor in which a sliding or rolling contact moves over an exposed area of the resistive element to change the ohmic value of the output. The functional tolerance (linearity), if given, of the output is greater than plus of minus 1 percent on linear outputs. Specified outputs such as sine, cosine, tangent, and the like, shall be considered to be precision. For items having manually positioned taps designed to be set and fixed prior to use, see resistor, adjustable. For items with step by step variation, see rheostat and resistor, step by step. For tandem-mounted items designed to function together as an attenuator (and rated accordingly), see attenuator, variable. Excludes:resistor (1), variable, nonwire wound; nonprecision; resistor (1), variable, nonwire wound, precision; and resistor (1), variable, wire wound, precision.

0.125 inches nominal shaft diameter, 1 section quantity, 0.086 inches nominal mounting hole diameter, not established reliability indicator, rectangular w/mounting holes/slots body style

Product Characteristics

Below you’ll find the complete technical specifications and performance data for this part, including material details and compliance information.

Section Quantity
1
Body Style
rectangular w/mounting holes/slots
Reliability Indicator
not established
Mounting Hole Diameter
0.086 inches nominal
Shaft Diameter
0.125 inches nominal
Shaft Length
0.063 inches nominal
Body Length
1.250 inches nominal
Body Width
0.280 inches nominal
Body Height
0.812 inches nominal
Shaft Style
round, slotted
Actuator Type
single shaft
Effective Electrical Rotation In Deg Angular Rotation
9000.0 nominal
Distance Between Mounting Hole Centers
0.500 inches nominal
Lateral Distance Between Mounting Hole Centers
1.000 inches nominal
Mounting Facility Quantity
4
Terminal Location
rear end
Mounting Method
unthreaded hole
Electrical Resistance Per Section
5.000 kilohms single section
Rotary Actuator Travel In Angular Deg
9000.0 nominal
Ambient Temp In Deg Celsius Per Section At Zero Percent Rated Power
135.0 single section
Power Dissipation Rating Per Section In Watts
2.0 free air single section
Resistance Tolerance Per Section In Percent
-10.0 to 10.0 single section
Actuator Travel Control Feature
clutch
Temp Coefficient Of Resistance Wire Per Section In Ppm Per Deg Celsius
-20.0 to 20.0 single section
Ambient Temp In Deg Celsius Per Section At Full Rated Power
50.0 single section
Terminal Type And Quantity
3 wire lead

Replaces National Stock Numbers

Below is a list of NSNs that have been officially superseded by this NSN:

NSN Name Date
5905-00-682-0128 No Name Available 07/01/1977

Related Parts

This NSN group includes multiple components designed to meet specific performance and operational standards. Each listing provides detailed specs, functionality data, and replacement compatibility information:

Part Number Name
207-1-502 Resistor,variable,wire Wound,non
207L1-502 Resistor,variable,wire Wound,non
240-1252P6 Resistor,variable,wire Wound,non
719299-159 Resistor,variable,wire Wound,non
SM152-6 Resistor,variable,wire Wound,non

FAQs

Find helpful answers about installation, operation, maintenance, compliance, and troubleshooting.

What is the FSCG of the NSN 5905-00-615-9381?
The FSCG of the NSN 5905-00-615-9381 is 5905
Does the NSN 5905-00-615-9381 have a Schedule B code assigned?
Yes, the Schedule B code is 8533390080
Does NSN 5905-00-615-9381 require demilitarization?
Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.
Does NSN 5905-00-615-9381 contain precious materials?
Precious metal content is unknown
Does NSN 5905-00-615-9381 contain hazardous materials?
Indicates there is no data in the hmirs and the nsn is in a fsc not generally suspected of containing hazardous materials.
When the NSN 5905-00-615-9381 was assigned to the Federal Catalog?
It was assigned 63 years ago, on Tue, Jan 1, 1963

Professional Distribution

Certified to meet the strict requirements of defense, aerospace, and hazardous materials distribution.

  • ITAR Registered
  • DDTC Registered
  • HAZMAT Certified
  • AS9120 Quality Standards
  • 100% Quality Inspections

You May Also Like

Browse other in-demand NSN parts sourced by professionals in defense, aerospace, and manufacturing sectors. Each component meets strict standards for quality and performance.

Pricing

Submit your request below and our team will respond quickly with up-to-date pricing, delivery estimates, and stock information:

ITAR Registered

Featured Parts

Explore our most requested parts, carefully selected based on customer demand and sourcing activity. Each listing provides current specifications, availability status, and item condition:

6515NCM163159
6515-01-471-6565
Ophthamology Fixation Set
6515NCM163160
6515-01-471-6566
Spatula and Spoon
6515NCM163162
6515-01-472-6021
Corneal Utility Eye Forceps
6515NCM163168
6515-01-658-4121
Rib Retractor
6515NCM163169
6515-01-658-6548
Sternum Retractor
6515NCM163170
6515-01-658-1570
Patient Vital Signs Monitor
6515NCM163171
6515-01-658-1584
Vital Signs Monitor Cable
6515NCM163172
6515-01-658-1603
Electrocardiograph Electrode Set
6515NCM163173
6510-01-658-4975
Ki Bleeding Control
6515NCM163174
6510-01-658-4967
Kit Bleeding Control
6515NCM163180
6515-01-589-9752
Tissue Embedding Co
6515NCM163181
6515-01-658-5244
Surgeons' Gloves
6515NCM163182
6515-01-555-3206
Bone Screw Tap
6515NCM163183
6515-01-555-3209
Spinal System Screwdriver Shaft
6515NCM163195
6515-01-659-1418
Urethral Catheter