JA-D2F002

View detailed technical data, stock status, and sourcing information for: JA-D2F002

DODParts.com distributes related products varnishes dopes paints, aircraft parts and consumables, electrical parts, fittings and other components for the aerospace and defense industries. Submit the short price quote form for part JA-D2F002 to receive an up to date pricing and availability quote by email.

JA-D2F002
Federal Supply Group
Electrical and Electronic Equipment Components
Federal Supply Classification
5945 Relays and Solenoids
National Stock Number
5945-01-287-6657
Item Name Code
32512
Assigment Date
10/25/1988 (37 years ago)

An electrical fitting with electrical contacts, constructed to be affixed to the end of a cable, conduit, coaxial line, cord or wiring for convenience in joining with other electrical connector(s) or printed wiring board and is not designed to be mounted on a bulkhead, chasses, panel, printed wiring board, or the like. Excludes:jack, telephone; jack, tip; plug, telephone; plug tip; insert, electrical connector; connector body (as modified); and socket, plug-in, electronic components. See also lead assembly, electrical; wiring harness (as modified); and cable assembly (as modified). For items without inserts, see shell, electrical connector.

0.140 inches minimum and 0.160 inches maximum single mounting facility mounting slot width, 1.396 inches minimum and 1.446 inches maximum single mounting facility center to center distance between mounting facilities parallel to length, 0.505 inches minimum and 0.525 inches maximum overall width, 1.698 inches minimum and 1.718 inches maximum overall length, 1.105 inches minimum and 1.125 inches maximum overall height

Product Characteristics

Below you’ll find the complete technical specifications and performance data for this part, including material details and compliance information.

Overall Length
1.698 inches minimum and 1.718 inches maximum
Center To Center Distance Between Mounting Facilities Parallel To Length
1.396 inches minimum and 1.446 inches maximum single mounting facility
Overall Height
1.105 inches minimum and 1.125 inches maximum
Overall Width
0.505 inches minimum and 0.525 inches maximum
Mounting Slot Width
0.140 inches minimum and 0.160 inches maximum single mounting facility
Case Material
unable to decode
Environmental Protection
hermetic
Fragility Factor
moderately rugged
Frequency In Hertz
400.0 nominal
Winding Quantity
1
Purpose For Which Designed
general
Coil Quantity
1
Duty Type
continuous
Arc Quenching Method
air
Mounting Facility Type And Quantity
unable to decode
Storage Type
general purpose warehouse
Features Provided
polarized
Cubic Measure
1.015 cubic inches
Mounting Facility Pattern
in-line single mounting facility
Nonpile-Up Main Contact Arrangement
2 pole, double throw, one position momentary
Nominal Operating Current Rating And Type
40.0 milliamperes ac single winding
Criticality Code Justification
feat
Time Delay
0.015 seconds maximum fixed operate time
Time Delay
0.05 seconds maximum fixed release time
Operating Voltage Rating And Type At Specified Temp
115.0 volts ac 25 deg celsius single winding
Main Contact Load Current Rating At Maximum Rated Voltage
10.0 amperes ac and 10.0 amperes dc resistive load
Main Contact Load Current Rating At Maximum Rated Voltage
2.0 amperes ac and 2.0 amperes dc lamp load
Main Contact Load Current Rating At Maximum Rated Voltage
4.0 amperes ac and 4.0 amperes dc motor load
Main Contact Load Current Rating At Maximum Rated Voltage
8.0 amperes ac and 8.0 amperes dc inductive load
Main Contact Maximum Voltage Rating In Volts
115.0 ac and 28.0 dc
Special Features
failure rate level 0.3 percent
Test Data Document
"81349-mil-r-6106 specification (includes engineering type bulletins, brochures,etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type data on certain environmental and performance requirements and test conditions that are shown as "typical", "average", "nominal", etc.)."
Terminal Type And Quantity
8 wire hook all functions
Specification/Standard Data
96906-ms27401 government standard

Replaces National Stock Numbers

Below is a list of NSNs that have been officially superseded by this NSN:

NSN Name Date
5945-01-006-1825 No Name Available 09/27/2018
5945-01-454-6166 No Name Available 11/01/2017

Related Parts

This NSN group includes multiple components designed to meet specific performance and operational standards. Each listing provides detailed specs, functionality data, and replacement compatibility information:

Part Number Name
E210-1438 Electromagnetic Relay
J-D2K-018 Electromagnetic Relay
JA-D2F002 Electromagnetic Relay
JA-D2K-018 Electromagnetic Relay
M27401-7X Electromagnetic Relay
M83536/11-001 Electromagnetic Relay
M83536/11-001L Electromagnetic Relay
M83536/11-001M Electromagnetic Relay
M83536/11-001P Electromagnetic Relay
MS27401-7U Electromagnetic Relay
MS27401-7X Electromagnetic Relay

FAQs

Find helpful answers about installation, operation, maintenance, compliance, and troubleshooting.

What is the FSCG of the NSN 5945-01-287-6657?
The FSCG of the NSN 5945-01-287-6657 is 5945
Does the NSN 5945-01-287-6657 have a Schedule B code assigned?
Yes, the Schedule B code is 8536490075
Does NSN 5945-01-287-6657 require demilitarization?
Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.
Does NSN 5945-01-287-6657 contain precious materials?
Item does not contain precious metal.
Does NSN 5945-01-287-6657 contain hazardous materials?
Indicates there is no data in the hmirs and the nsn is in a fsc not generally suspected of containing hazardous materials.
When the NSN 5945-01-287-6657 was assigned to the Federal Catalog?
It was assigned 37 years ago, on Tue, Oct 25, 1988

Professional Distribution

Certified to meet the strict requirements of defense, aerospace, and hazardous materials distribution.

  • ITAR Registered
  • DDTC Registered
  • HAZMAT Certified
  • AS9120 Quality Standards
  • 100% Quality Inspections

You May Also Like

Browse other in-demand NSN parts sourced by professionals in defense, aerospace, and manufacturing sectors. Each component meets strict standards for quality and performance.

Pricing

Submit your request below and our team will respond quickly with up-to-date pricing, delivery estimates, and stock information:

ITAR Registered

Featured Parts

Explore our most requested parts, carefully selected based on customer demand and sourcing activity. Each listing provides current specifications, availability status, and item condition:

GRH40C0G680G050B
5910-01-359-4058
Ceramic Dielectr Fixed Capacitor
GRH40COG2R2C50V
5910-01-329-1099
Ceramic Dielectr Fixed Capacitor
GRH40COG3R3C50V
5910-01-328-8939
Ceramic Dielectr Fixed Capacitor
GRH40COG4R7D50V
5910-01-328-8538
Ceramic Dielectr Fixed Capacitor
GRH40COG5R6D50V
5910-01-328-8539
Ceramic Dielectr Fixed Capacitor
GRH40COG6R8D50V
5910-01-328-8535
Ceramic Dielectr Fixed Capacitor
GRH40X7R103K50V
5910-01-328-8536
Ceramic Dielectr Fixed Capacitor
GRH41-7G
6615-00-723-4585
Rate Gyroscope
GRH42-2C0G102F050C
5910-01-348-9979
Ceramic Dielectr Fixed Capacitor
GRH42-2C0G471G050B
5910-01-359-4059
Ceramic Dielectr Fixed Capacitor
GRH42-2C0G681G050B
5910-01-359-4056
Ceramic Dielectr Fixed Capacitor
GRH42-2C0G681J050C
5910-01-359-4056
Ceramic Dielectr Fixed Capacitor
GRH42-2C0G821G050B
5910-01-359-3275
Ceramic Dielectr Fixed Capacitor
GRH42-2C0G821J050B
5910-01-359-3275
Ceramic Dielectr Fixed Capacitor
GRH42-2C0G821J050C
5910-01-359-3275
Ceramic Dielectr Fixed Capacitor