1. Home /
  2. Catalog /
  3. Relays and Solenoids /
  4. 5945-00-827-9044

5945-00-827-9044

Find complete technical information, availability, and procurement data for: 5945-00-827-9044

DODParts.com distributes related products varnishes dopes paints, aircraft parts and consumables, electrical parts, fittings and other components for the aerospace and defense industries. Submit the short price quote form for NSN 5945-00-827-9044 to receive an up to date pricing and availability quote by email.

5945-00-827-9044
Federal Supply Group
Electrical and Electronic Equipment Components
Federal Supply Classification
5945 Relays and Solenoids
National Stock Number
5945-00-827-9044
Item Name Code
32512
Assigment Date
01/01/1962 (64 years ago)

An electrical fitting with electrical contacts constructed to be affixed to the end of a cable, conduit, coaxial line, cord, wire (includes printed/etched), printed wiring board, or the like for convenience in joining with another electrical connector or printed wiring board. It is designed to be mounted on a bulkhead, chassis, panel, wall, printed wiring board, or the like. Excludes:lampholder; jack,telephone; jack,tip; insert electrical connector; insert module,electrical connector; connector body (as modified) and socket,plug-in electronic components. See also wiring harness (as modified) and cable assembly (as modified). For items with termination wires of more than four inches in length, see lead assembly,electrical. For items without inserts, see shell,electrical connector.

4.010 inches maximum overall height, 2.700 inches maximum overall width, 2.188 inches nominal single mounting facility center to center distance between mounting facilities parallel to width, 2.835 inches maximum overall length, unable to decode case material

Product Characteristics

Below you’ll find the complete technical specifications and performance data for this part, including material details and compliance information.

Overall Length
2.835 inches maximum
Center To Center Distance Between Mounting Facilities Parallel To Width
2.188 inches nominal single mounting facility
Overall Height
4.010 inches maximum
Overall Width
2.700 inches maximum
Case Material
unable to decode
Environmental Protection
hermetic
Unthreaded Mounting Hole Diameter
0.218 inches nominal single mounting facility
Fragility Factor
moderately rugged
Winding Quantity
1
Purpose For Which Designed
general
Coil Quantity
1
Winding Dc Resistance Rating
78.0 ohms nominal single winding
Duty Type
continuous
Arc Quenching Method
air
Mounting Facility Type And Quantity
unable to decode
Storage Type
general purpose warehouse
Cubic Measure
30.694 cubic inches
Mounting Facility Pattern
in-line single mounting facility
Nonpile-Up Main Contact Arrangement
1 pole, single throw, normally open, double make, momentary action
Nominal Operating Current Rating And Type
500.0 milliamperes dc single winding
Time Delay
0.01 seconds maximum fixed release time
Time Delay
0.02 seconds maximum fixed operate time
Nonpile-Up Auxiliary Contact Arrangement
1 pole, single throw, normally closed, double break, momentary action and 1 pole, single throw, normally open, double make, momentary action
Auxiliary Contact Maximum Voltage Rating In Volts
115.0 ac and 28.0 dc
Operating Voltage Rating And Type At Specified Temp
28.0 volts dc 25 deg celsius single winding
Main Contact Load Current Rating At Maximum Rated Voltage
25.0 amperes ac and 25.0 amperes dc lamp load
Main Contact Load Current Rating At Maximum Rated Voltage
50.0 amperes ac and 50.0 amperes dc inductive load
Main Contact Load Current Rating At Maximum Rated Voltage
50.0 amperes ac and 50.0 amperes dc motor load
Main Contact Load Current Rating At Maximum Rated Voltage
50.0 amperes ac and 50.0 amperes dc resistive load
Main Contact Maximum Voltage Rating In Volts
115.0 ac and 28.0 dc
Auxiliary Contact Load Current Rating At Maximum Rated Voltage
5.0 amperes ac and 5.0 amperes dc inductive load
Auxiliary Contact Load Current Rating At Maximum Rated Voltage
5.0 amperes ac and 5.0 amperes dc resistive load
Auxiliary Contact Load Current Rating At Maximum Rated Voltage
750.0 milliamperes ac and 750.0 milliamperes dc lamp load
Test Data Document
"81349-mil-r-6106 specification (includes engineering type bulletins, brochures,etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type data on certain environmental and performance requirements and test conditions that are shown as "typical", "average", "nominal", etc.)."
Terminal Type And Quantity
8 threaded stud all functions
Specification/Standard Data
96906-ms24140 government standard

Replaces National Stock Numbers

Below is a list of NSNs that have been officially superseded by this NSN:

NSN Name Date
5945-00-730-1277 No Name Available 11/25/2003
5945-01-013-7785 No Name Available 10/01/1976

Related Parts

This NSN group includes multiple components designed to meet specific performance and operational standards. Each listing provides detailed specs, functionality data, and replacement compatibility information:

Part Number Name
455-0399-002 Electromagnetic Relay
6042H156 Electromagnetic Relay
6042H2 Electromagnetic Relay
MS24140-D2 Electromagnetic Relay

FAQs

Find helpful answers about installation, operation, maintenance, compliance, and troubleshooting.

What is the FSCG of the NSN 5945-00-827-9044?
The FSCG of the NSN 5945-00-827-9044 is 5945
Does the NSN 5945-00-827-9044 have a Schedule B code assigned?
Yes, the Schedule B code is 8536490075
Does NSN 5945-00-827-9044 require demilitarization?
Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.
Does NSN 5945-00-827-9044 contain precious materials?
Item does not contain precious metal.
Does NSN 5945-00-827-9044 contain hazardous materials?
Indicates there is no data in the hmirs and the nsn is in a fsc not generally suspected of containing hazardous materials.
When the NSN 5945-00-827-9044 was assigned to the Federal Catalog?
It was assigned 64 years ago, on Mon, Jan 1, 1962

Professional Distribution

Certified to meet the strict requirements of defense, aerospace, and hazardous materials distribution.

  • ITAR Registered
  • DDTC Registered
  • HAZMAT Certified
  • AS9120 Quality Standards
  • 100% Quality Inspections

You May Also Like

Browse other in-demand NSN parts sourced by professionals in defense, aerospace, and manufacturing sectors. Each component meets strict standards for quality and performance.

Pricing

Submit your request below and our team will respond quickly with up-to-date pricing, delivery estimates, and stock information:

ITAR Registered

Featured Parts

Explore our most requested parts, carefully selected based on customer demand and sourcing activity. Each listing provides current specifications, availability status, and item condition:

YR5800N45-0217
4720-00-019-7854
Nonmetallic Hose Assembly
YR580376-5
4920-01-159-8977
Actuator Cylinder Assembly
YR59S5801-264399ALT1ITEM2
4320-00-336-8768
Body Ring
YR59S5801-264399ALT1ITEM4
4320-00-336-5234
Shaft Sleeve
YR59S5801-264399ALT1PC35
4320-00-336-8768
Body Ring
YR59S5801-264399ALT1PC51
4320-00-336-5234
Shaft Sleeve
YR59S5801-264401ALT1PC35
4320-00-336-8768
Body Ring
YR59S5801-264401ALT1PC51
4320-00-336-5234
Shaft Sleeve
YR59S5901-508489ITEM3
5999-00-395-2509
Electrical Contact Assembly
YR6
5315-00-248-2381
Headless Straight Pin
YR607
3110-00-516-5289
Annular Ball Bearing
YR62S4700-144228PC7
5310-00-723-2906
Spring Tension Washer
YR64
3120-00-374-4166
Thrust Washer Bearing
YR66
5365-00-598-1558
Shim
YR660
7025-01-569-8678
Disk Drive Unit