TIP00005

View detailed technical data, stock status, and sourcing information for: TIP00005

DODParts.com distributes related products varnishes dopes paints, aircraft parts and consumables, electrical parts, fittings and other components for the aerospace and defense industries. Submit the short price quote form for part TIP00005 to receive an up to date pricing and availability quote by email.

TIP00005
Federal Supply Group
Electrical and Electronic Equipment Components
Federal Supply Classification
5945 Relays and Solenoids
National Stock Number
5945-00-826-2218
Item Name Code
32512
Assigment Date
01/01/1962 (64 years ago)

A switch with a quick-acting mechanism actuated by a highly delicate tactile contact. It may include a timer function. Includes membrane switch. Excludes: switch,flexible; switch,pressure; and switch,thermostatic.

2.312 inches nominal single mounting facility center to center distance between mounting facilities parallel to length, 3.312 inches maximum overall width, 3.625 inches maximum overall length, 3.188 inches maximum overall height, 2.750 inches nominal single mounting facility center to center distance between mounting facilities parallel to width

Product Characteristics

Below you’ll find the complete technical specifications and performance data for this part, including material details and compliance information.

Overall Length
3.625 inches maximum
Center To Center Distance Between Mounting Facilities Parallel To Length
2.312 inches nominal single mounting facility
Center To Center Distance Between Mounting Facilities Parallel To Width
2.750 inches nominal single mounting facility
Overall Height
3.188 inches maximum
Overall Width
3.312 inches maximum
Case Material
unable to decode
Environmental Protection
hermetic
Unthreaded Mounting Hole Diameter
0.219 inches nominal single mounting facility
Fragility Factor
moderately rugged
Winding Quantity
1
Purpose For Which Designed
general
Coil Quantity
1
Winding Dc Resistance Rating
71.5 ohms nominal single winding
Duty Type
continuous
Arc Quenching Method
air
Mounting Facility Type And Quantity
unable to decode
Storage Type
general purpose warehouse
Cubic Measure
38.275 cubic inches
Mounting Facility Pattern
rectangular single mounting facility
Nonpile-Up Main Contact Arrangement
3 pole, single throw, normally open, double make, momentary action
Time Delay
0.015 seconds maximum fixed release time
Time Delay
0.02 seconds maximum fixed operate time
Operating Voltage Rating And Type At Specified Temp
28.0 volts dc 25 deg celsius single winding
Main Contact Load Current Rating At Maximum Rated Voltage
50.0 amperes ac and 50.0 amperes dc inductive load
Main Contact Load Current Rating At Maximum Rated Voltage
50.0 amperes ac and 50.0 amperes dc motor load
Main Contact Load Current Rating At Maximum Rated Voltage
50.0 amperes ac and 50.0 amperes dc resistive load
Main Contact Maximum Voltage Rating In Volts
115.0 ac and 28.0 dc
Test Data Document
"81349-mil-r-6106 specification (includes engineering type bulletins, brochures,etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type data on certain environmental and performance requirements and test conditions that are shown as "typical", "average", "nominal", etc.)."
Terminal Type And Quantity
8 threaded stud all functions
Specification/Standard Data
96906-ms24193 government standard

Replaces National Stock Numbers

Below is a list of NSNs that have been officially superseded by this NSN:

NSN Name Date
5945-00-258-3331 No Name Available 07/24/1968
5945-00-552-4988 No Name Available 06/01/2002

Related Parts

This NSN group includes multiple components designed to meet specific performance and operational standards. Each listing provides detailed specs, functionality data, and replacement compatibility information:

Part Number Name
5945008262218 Electromagnetic Relay
5945PL1066010 Electromagnetic Relay
5945PL2074167 Electromagnetic Relay
9565H94 Electromagnetic Relay
956H594 Electromagnetic Relay
MS24193-D1 Electromagnetic Relay
TIP00005 Electromagnetic Relay

FAQs

Find helpful answers about installation, operation, maintenance, compliance, and troubleshooting.

What is the FSCG of the NSN 5945-00-826-2218?
The FSCG of the NSN 5945-00-826-2218 is 5945
Does the NSN 5945-00-826-2218 have a Schedule B code assigned?
Yes, the Schedule B code is 8536490075
Does NSN 5945-00-826-2218 require demilitarization?
Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.
Does NSN 5945-00-826-2218 contain precious materials?
Precious metal content is unknown
Does NSN 5945-00-826-2218 contain hazardous materials?
Indicates there is no data in the hmirs and the nsn is in a fsc not generally suspected of containing hazardous materials.
When the NSN 5945-00-826-2218 was assigned to the Federal Catalog?
It was assigned 64 years ago, on Mon, Jan 1, 1962

Professional Distribution

Certified to meet the strict requirements of defense, aerospace, and hazardous materials distribution.

  • ITAR Registered
  • DDTC Registered
  • HAZMAT Certified
  • AS9120 Quality Standards
  • 100% Quality Inspections

You May Also Like

Browse other in-demand NSN parts sourced by professionals in defense, aerospace, and manufacturing sectors. Each component meets strict standards for quality and performance.

Pricing

Submit your request below and our team will respond quickly with up-to-date pricing, delivery estimates, and stock information:

ITAR Registered

Featured Parts

Explore our most requested parts, carefully selected based on customer demand and sourcing activity. Each listing provides current specifications, availability status, and item condition:

536706-4
5999-00-568-3727
Delay Line
536706-6
5999-00-568-3729
Delay Line
536706-7
5999-00-568-3728
Delay Line
536706-8
5999-01-021-1315
Delay Line
5367065
5977-00-232-5335
Electrical Contact Brush
536707
6610-00-817-5715
Air Data Compu Case
536707-1
5935-00-564-4189
Electrical Receptacle Connector
536707-2
5935-00-576-6507
Electrical Receptacle Connector
536707-3
5935-00-564-4219
Electrical Receptacle Connector
536709-2
5910-01-054-9248
Electrolytic Fixed Capacitor
536709-3
5910-00-294-9432
Electrolytic Fixed Capacitor
536709-33
5910-00-158-5372
Electrolytic Fixed Capacitor
536709-4
5910-00-294-9439
Electrolytic Fixed Capacitor
536709-5
5910-01-005-1834
Electrolytic Fixed Capacitor
536709-53
5910-01-005-1834
Electrolytic Fixed Capacitor