5920-00-581-4144

Find complete technical information, availability, and procurement data for: 5920-00-581-4144

DODParts.com distributes related products varnishes dopes paints, aircraft parts and consumables, electrical parts, fittings and other components for the aerospace and defense industries. Submit the short price quote form for NSN 5920-00-581-4144 to receive an up to date pricing and availability quote by email.

5920-00-581-4144
Federal Supply Group
Electrical and Electronic Equipment Components
National Stock Number
5920-00-581-4144
Item Name Code
00248
Assigment Date
01/01/1963 (63 years ago)

An electrical fitting with electrical contacts, constructed to be affixed to the end of a cable, conduit, coaxial line, cord or wiring for convenience in joining with other electrical connector(s) or printed wiring board and is not designed to be mounted on a bulkhead, chasses, panel, printed wiring board, or the like. Excludes:jack, telephone; jack, tip; plug, telephone; plug tip; insert, electrical connector; connector body (as modified); and socket, plug-in, electronic components. See also lead assembly, electrical; wiring harness (as modified); and cable assembly (as modified). For items without inserts, see shell, electrical connector.

2.000 continuous current rating in amps, 250.0 ac and 250.0 dc maximum voltage rating in volts, tube type body style, 0.250 inches nominal overall diameter, 1.250 inches nominal overall length

Product Characteristics

Below you’ll find the complete technical specifications and performance data for this part, including material details and compliance information.

Body Style
tube type
Overall Length
1.250 inches nominal
Overall Diameter
0.250 inches nominal
Continuous Current Rating In Amps
2.000
Maximum Voltage Rating In Volts
250.0 ac and 250.0 dc
Circuit Over-Current Interruption Type
time delay
Interruption Indicator Method
visible element
Features Provided
nonrenewable fusible element
Circuit Over-Current Interruption Delay Time In Seconds
3.0 300 pct of current rating
Material
glass case
Surface Treatment
nickel terminal

Replaces National Stock Numbers

Below is a list of NSNs that have been officially superseded by this NSN:

NSN Name Date
5920-00-465-0573 No Name Available 02/28/1973
5920-00-581-6129 No Name Available 01/01/1963
5920-00-807-8659 No Name Available 02/01/1981
5920-01-081-0002 No Name Available 07/01/1982

Related Parts

This NSN group includes multiple components designed to meet specific performance and operational standards. Each listing provides detailed specs, functionality data, and replacement compatibility information:

Part Number Name
128102004 Cartridge Fuse
159-0023 Cartridge Fuse
159-0023-00 Cartridge Fuse
159-023 Cartridge Fuse
16750231-032 Cartridge Fuse
226-1009P8 Cartridge Fuse
246-004 Cartridge Fuse
27F893 Cartridge Fuse
3AGX2TL Cartridge Fuse
5050312 Cartridge Fuse
5096-059 Cartridge Fuse
510403 Cartridge Fuse
5920005814144 Cartridge Fuse
9174801 Cartridge Fuse
A586 Cartridge Fuse
BTL65626A Cartridge Fuse
MDL2A Cartridge Fuse
MDX-2 Cartridge Fuse
MDX2 Cartridge Fuse
MDX2A Cartridge Fuse
MDX2AMP Cartridge Fuse
TFAJ0200 Cartridge Fuse

FAQs

Find helpful answers about installation, operation, maintenance, compliance, and troubleshooting.

What is the FSCG of the NSN 5920-00-581-4144?
The FSCG of the NSN 5920-00-581-4144 is 5920
Does the NSN 5920-00-581-4144 have a Schedule B code assigned?
Yes, the Schedule B code is 8536100020
Does NSN 5920-00-581-4144 require demilitarization?
Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.
Does NSN 5920-00-581-4144 contain precious materials?
Item does not contain precious metal.
Does NSN 5920-00-581-4144 contain hazardous materials?
Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
When the NSN 5920-00-581-4144 was assigned to the Federal Catalog?
It was assigned 63 years ago, on Tue, Jan 1, 1963

Professional Distribution

Certified to meet the strict requirements of defense, aerospace, and hazardous materials distribution.

  • ITAR Registered
  • DDTC Registered
  • HAZMAT Certified
  • AS9120 Quality Standards
  • 100% Quality Inspections

You May Also Like

Browse other in-demand NSN parts sourced by professionals in defense, aerospace, and manufacturing sectors. Each component meets strict standards for quality and performance.

Pricing

Submit your request below and our team will respond quickly with up-to-date pricing, delivery estimates, and stock information:

ITAR Registered

Featured Parts

Explore our most requested parts, carefully selected based on customer demand and sourcing activity. Each listing provides current specifications, availability status, and item condition:

RW70U4990D
5905-00-223-3029
Wire Wound Fixed Resistor
RW70U4990F
5905-00-921-4228
Resistor,fixed,wire Wound,induct
RW70U49R9B
5905-01-237-6554
Resistor,fixed,wire Wound,induct
RW70U49R9F
5905-00-900-0774
Resistor,fixed,wire Wound,induct
RW70U4R02F
5905-01-197-5427
Resistor,fixed,wire Wound,induct
RW70U4R22F
5905-01-058-9852
Resistor,fixed,wire Wound,induct
RW70U4R53F
5905-00-942-9691
Resistor,fixed,wire Wound,induct
RW70U4R70F
5905-01-161-0861
Resistor,fixed,wire Wound,induct
RW70U4R75F
5905-00-839-4077
Resistor,fixed,wire Wound,induct
RW70U4R76B
5905-01-239-4807
Resistor,fixed,wire Wound,induct
RW70U4R87F
5905-01-259-5037
Resistor,fixed,wire Wound,induct
RW70U4R99F
5905-00-900-1449
Resistor,fixed,wire Wound,induct
RW70U5000B
5905-00-012-1875
Wire Wound Fixed Resistor
RW70U50R0B
5905-01-259-5048
Resistor,fixed,wire Wound,induct
RW70U5110B
5905-01-261-3580
Resistor,fixed,wire Wound,induct