Find complete technical information, availability, and procurement data for: 5915-00-945-8953

DODParts.com distributes related products varnishes dopes paints, aircraft parts and consumables, electrical parts, fittings and other components for the aerospace and defense industries. Submit the short price quote form for NSN 5915-00-945-8953 to receive an up to date pricing and availability quote by email.

5915-00-945-8953
Federal Supply Group
Electrical and Electronic Equipment Components
Federal Supply Classification
5915 Filters and Networks
National Stock Number
5915-00-945-8953
Item Name Code
00765
Assigment Date
03/14/1966 (60 years ago)

64.380 inches nominal overall length, 4.380 inches nominal body length, 3.500 inches nominal distance between centerlines of mounting facilities parallel to body length, 2.380 inches nominal body width, 2.000 inches nominal body height

Product Characteristics

Below you’ll find the complete technical specifications and performance data for this part, including material details and compliance information.

Overall Length
64.380 inches nominal
Body Length
4.380 inches nominal
Body Width
2.380 inches nominal
Body Height
2.000 inches nominal
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
3.500 inches nominal
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
1.500 inches nominal
Operating Temp Range
-20.0 to 70.0 celsius
Source Impedance Rating Per Function
50.0 ohms 1st radio interference 1st function
Source Impedance Rating Per Function
50.0 ohms 3rd radio interference 3rd function
Source Impedance Rating Per Function
50.0 ohms 2nd radio interference 2nd function
Source Impedance Rating Per Function
50.0 ohms 6th radio interference 6th function
Source Impedance Rating Per Function
50.0 ohms 4th radio interference 4th function
Source Impedance Rating Per Function
50.0 ohms 5th radio interference 5th function
Load Impedance Per Function
50.0 ohms 1st radio interference 1st function
Load Impedance Per Function
50.0 ohms 3rd radio interference 3rd function
Load Impedance Per Function
50.0 ohms 2nd radio interference 2nd function
Load Impedance Per Function
50.0 ohms 6th radio interference 6th function
Load Impedance Per Function
50.0 ohms 4th radio interference 4th function
Load Impedance Per Function
50.0 ohms 5th radio interference 5th function
Power Line Frequency Rating Per Function In Hertz
60.0 1st radio interference 1st function
Power Line Frequency Rating Per Function In Hertz
60.0 2nd radio interference 2nd function
Power Line Frequency Rating Per Function In Hertz
60.0 3rd radio interference 3rd function
Power Line Frequency Rating Per Function In Hertz
60.0 4th radio interference 4th function
Power Line Frequency Rating Per Function In Hertz
60.0 5th radio interference 5th function
Power Line Frequency Rating Per Function In Hertz
60.0 6th radio interference 6th function
Operating Current Rating Per Function In Amps
3.0 1st radio interference 1st function
Operating Current Rating Per Function In Amps
3.0 2nd radio interference 2nd function
Operating Current Rating Per Function In Amps
3.0 3rd radio interference 3rd function
Operating Current Rating Per Function In Amps
3.0 4th radio interference 4th function
Operating Current Rating Per Function In Amps
3.0 5th radio interference 5th function
Operating Current Rating Per Function In Amps
3.0 6th radio interference 6th function
Principal Circuitry Type Per Function
inductance-capacitance 1st radio interference 1st function
Principal Circuitry Type Per Function
inductance-capacitance 2nd radio interference 2nd function
Principal Circuitry Type Per Function
inductance-capacitance 3rd radio interference 3rd function
Principal Circuitry Type Per Function
inductance-capacitance 4th radio interference 4th function
Principal Circuitry Type Per Function
inductance-capacitance 5th radio interference 5th function
Principal Circuitry Type Per Function
inductance-capacitance 6th radio interference 6th function
Mounting Facility Screw Thread Series Designator
unc
Inclosure Type
hermetically sealed
Mounting Facility Type And Quantity
4 threaded hole
Functional Terminal Type And Quantity
6 wire lead output 2nd function
Functional Terminal Type And Quantity
6 wire lead input 1st function
Operating Voltage Rating And Type Per Function
115.0 volts ac 1st radio interference 1st function
Operating Voltage Rating And Type Per Function
115.0 volts ac 2nd radio interference 2nd function
Operating Voltage Rating And Type Per Function
115.0 volts ac 3rd radio interference 3rd function
Operating Voltage Rating And Type Per Function
115.0 volts ac 4th radio interference 4th function
Operating Voltage Rating And Type Per Function
115.0 volts ac 5th radio interference 5th function
Operating Voltage Rating And Type Per Function
115.0 volts ac 6th radio interference 6th function
Nominal Thread Size
0.164 inches
Body Material
metal
Body Surface Treatment
tin
Special Features
six filtered functions
Style Designator
rectangular terminal/terminals on opposite surfaces

Related Parts

This NSN group includes multiple components designed to meet specific performance and operational standards. Each listing provides detailed specs, functionality data, and replacement compatibility information:

Part Number Name
5003-4021 Radio Frequency Interfere Filter
85915-0106-0001 Radio Frequency Interfere Filter

FAQs

Find helpful answers about installation, operation, maintenance, compliance, and troubleshooting.

What is the FSCG of the NSN 5915-00-945-8953?
The FSCG of the NSN 5915-00-945-8953 is 5915
Does the NSN 5915-00-945-8953 have a Schedule B code assigned?
Yes, the Schedule B code is 8527995030
Does NSN 5915-00-945-8953 require demilitarization?
Usml or ccl military items - demil required. Destroy item and components to prevent restoration or repair to a usable condition. (note 5).
Does NSN 5915-00-945-8953 contain precious materials?
Precious metal content is unknown
Does NSN 5915-00-945-8953 contain hazardous materials?
Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
When the NSN 5915-00-945-8953 was assigned to the Federal Catalog?
It was assigned 60 years ago, on Mon, Mar 14, 1966

Professional Distribution

Certified to meet the strict requirements of defense, aerospace, and hazardous materials distribution.

  • ITAR Registered
  • DDTC Registered
  • HAZMAT Certified
  • AS9120 Quality Standards
  • 100% Quality Inspections

You May Also Like

Browse other in-demand NSN parts sourced by professionals in defense, aerospace, and manufacturing sectors. Each component meets strict standards for quality and performance.

Pricing

Submit your request below and our team will respond quickly with up-to-date pricing, delivery estimates, and stock information:

ITAR Registered

Featured Parts

Explore our most requested parts, carefully selected based on customer demand and sourcing activity. Each listing provides current specifications, availability status, and item condition:

C10243-27
6625-01-193-0270
Test Lead
C10243-3
3010-01-315-4450
Flexible Coupling Sleeve
C10243-30
6625-01-193-0271
Test Lead
C10243-31
6625-01-201-4459
Test Lead
C10243-8
6625-01-192-4379
Test Lead
C10243 COUPLING W 2.5S
3010-01-354-4977
Flexible Shaft Coupling
C10243 PIECE 1
3010-01-358-8704
Shaft Coupling Half
C10243 PIECE 2
3010-01-358-8705
Shaft Coupling Half
C10243 PIECE 3
3010-01-315-4450
Flexible Coupling Sleeve
C10243 PIECE 6
5330-01-360-4810
Nonmetallic Angle Seal
C10243 PIECE 7
5325-01-360-9058
Retaining Ring
C10244
3010-01-410-7978
Shaft Coupling Half
C10244-2
5985-01-210-1795
Electrical Dummy Load
C10245-1
5985-01-210-1835
Radio Frequency Reflect Isolator
C10245-2
5985-01-263-4076