F20-120

View detailed technical data, stock status, and sourcing information for: F20-120

DODParts.com distributes related products varnishes dopes paints, aircraft parts and consumables, electrical parts, fittings and other components for the aerospace and defense industries. Submit the short price quote form for part F20-120 to receive an up to date pricing and availability quote by email.

F20-120
Federal Supply Group
Electrical and Electronic Equipment Components
National Stock Number
5977-00-265-2914
Item Name Code
00302
Assigment Date
01/01/1963 (63 years ago)

An item specifically designed to be used in the transfer of electrical energy to or from another conducting surface. Either the brush or the surface is continually moving during the transfer of energy. The brush is usually composed in part of some form of the element carbon. Includes: (1) a single brush either with or without an attached shunt (flexible wire lead) and/or a helical or flat type pressure spring; (2) a split brush composed of two or more pieces (wafers), which are used in place of one brush usually connected together by individual shunts to a common terminal; (3) paired brushes composed of two identical or non-identical brushes connected together by a common shunt either with or without pressure springs or connected by individual shunts to a common terminal, or with pressure springs and connected to a common bar, bracket or the like either with or without individual shunts; (4) multiple brushes composed of more than two identical or non-identical brushes without pressure springs connected by individual shunts to a common terminal, or with pressure springs and connected to a common bar, bracket or the like by individual shunts. Does not include moving contacts which make and slide past stationary contacts, but are stationary while the circuit is conducting, such as the sliding contacts on a rheostat or the stationary contact on a synchro. Excludes: contact, electrical; and contact assembly, electrical.

0.436 inches nominal width, 0.281 inches nominal thickness, rectangular commutator body style, 8 shunt position designator, 0.750 inches nominal radius

Product Characteristics

Below you’ll find the complete technical specifications and performance data for this part, including material details and compliance information.

Shunt Position Designator
8
Body Style
rectangular commutator
Radius
0.750 inches nominal
Width
0.436 inches nominal
Thickness
0.281 inches nominal
Length
0.781 inches nominal
Brush Shunt Length
1.188 inches nominal all shunts
Terminal Hole Diameter
0.200 inches nominal
Top Style
beveled front
Contact Face Style
concave
Shunt Insulation Provision And Quantity
2 uninsulated
Angle
15.0 degrees nominal
Material
electrographitic
Material Document And Classification
stackpole carbon co,gr v53 mfr ref single material response
Style Designator
one piece
Terminal Type And Quantity
1 flag w/hole

Replaces National Stock Numbers

Below is a list of NSNs that have been officially superseded by this NSN:

NSN Name Date
5977-00-679-5687 No Name Available 01/01/1963

Related Parts

This NSN group includes multiple components designed to meet specific performance and operational standards. Each listing provides detailed specs, functionality data, and replacement compatibility information:

Part Number Name
7971686 Electrical Contact Brush
F20-120 Electrical Contact Brush

FAQs

Find helpful answers about installation, operation, maintenance, compliance, and troubleshooting.

What is the FSCG of the NSN 5977-00-265-2914?
The FSCG of the NSN 5977-00-265-2914 is 5977
Does the NSN 5977-00-265-2914 have a Schedule B code assigned?
Yes, the Schedule B code is 8545200000
Does NSN 5977-00-265-2914 require demilitarization?
Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.
Does NSN 5977-00-265-2914 contain precious materials?
Item does not contain precious metal.
Does NSN 5977-00-265-2914 contain hazardous materials?
Indicates there is no data in the hmirs and the nsn is in a fsc not generally suspected of containing hazardous materials.
When the NSN 5977-00-265-2914 was assigned to the Federal Catalog?
It was assigned 63 years ago, on Tue, Jan 1, 1963

Professional Distribution

Certified to meet the strict requirements of defense, aerospace, and hazardous materials distribution.

  • ITAR Registered
  • DDTC Registered
  • HAZMAT Certified
  • AS9120 Quality Standards
  • 100% Quality Inspections

You May Also Like

Browse other in-demand NSN parts sourced by professionals in defense, aerospace, and manufacturing sectors. Each component meets strict standards for quality and performance.

Pricing

Submit your request below and our team will respond quickly with up-to-date pricing, delivery estimates, and stock information:

ITAR Registered

Featured Parts

Explore our most requested parts, carefully selected based on customer demand and sourcing activity. Each listing provides current specifications, availability status, and item condition:

RWR84S1000FS
5905-01-158-2301
Resistor,fixed,wire Wound,induct
RWR84S1001FM
5905-00-256-2114
Wire Wound Fixed Resistor
RWR84S1001FP
5905-01-490-4213
Resistor,fixed,wire Wound,induct
RWR84S1001FR
5905-01-192-9095
Resistor,fixed,wire Wound,induct
RWR84S1001FS
5905-01-192-9095
Resistor,fixed,wire Wound,induct
RWR84S1002FM
5905-01-186-6788
Resistor,fixed,wire Wound,induct
RWR84S1002FP
5905-01-186-6788
Resistor,fixed,wire Wound,induct
RWR84S1002FR
5905-01-186-6788
Resistor,fixed,wire Wound,induct
RWR84S1002FS
5905-01-186-6788
Resistor,fixed,wire Wound,induct
RWR84S101FS
5905-01-158-2301
Resistor,fixed,wire Wound,induct
RWR84S1020FR
5905-01-265-9767
Resistor,fixed,wire Wound,induct
RWR84S1020FS
5905-01-265-9767
Resistor,fixed,wire Wound,induct
RWR84S1050FS
5905-01-261-3661
Resistor,fixed,wire Wound,induct
RWR84S1051FR
5905-01-265-9768
Resistor,fixed,wire Wound,induct
RWR84S1051FS
5905-01-265-9768
Resistor,fixed,wire Wound,induct