M01055-E3390-Z-S41

View detailed technical data, stock status, and sourcing information for: M01055-E3390-Z-S41

DODParts.com distributes related products varnishes dopes paints, aircraft parts and consumables, electrical parts, fittings and other components for the aerospace and defense industries. Submit the short price quote form for part M01055-E3390-Z-S41 to receive an up to date pricing and availability quote by email.

M01055-E3390-Z-S41
Federal Supply Group
Instruments and Laboratory Equipment
National Stock Number
6625-01-302-0890
Item Name Code
16450
Assigment Date
06/09/1989 (37 years ago)

An instrument which measures electric current and is calibrated and marked in amperes or any multiple and/or submultiple thereof. The value may be expressed by means of a pointer and calibrated dial or a digital readout display. For current detecting type of devices, see galvanometer.

25 single indicator single range scale division quantity, 96.0 millimeters nominal overall width, 96.0 millimeters nominal overall height, ac circuit current for which designed, 67.0 millimeters maximum overall length

Product Characteristics

Below you’ll find the complete technical specifications and performance data for this part, including material details and compliance information.

Circuit Current For Which Designed
ac
Overall Length
67.0 millimeters maximum
Overall Height
96.0 millimeters nominal
Overall Width
96.0 millimeters nominal
Scale Division Quantity
25 single indicator single range
Environmental Protection
cold resistant and heat resistant and shock resistant and vibration resistant
Indicator Type
dial w/pointer
Installation Design
panel
Frequency Response Range
+15.000 to 65.000 hertz
Dial Scale Marking Color
black single indicator single range
Accuracy In Percent
-1.5 to 1.5 at full scale single indicator single range
Panel For Which Designed
nonmagnetic
Meter Depth Behind Mounting Flange
62.0 millimeters maximum
Meter Body Width Behind Mounting Flange
88.0 millimeters nominal
Movement Type
moving iron vane
Background Color
white single indicator single range
Pointer Color
black single indicator single range
Power Source
external
Mounting Facility Type And Quantity
2 clamp and 1 flange and 2 screw
Scale Graduation Type
linear single indicator single range
Measurement Range
+0.0 to 500.0 amperes, ac single indicator single range
Circuit Construction Type
nonelectronic
Meter Body Height Behind Mounting Flange
88.0 millimeters nominal
Features Provided
transformer and zero adjuster
Circuit Attachment Method And Quantity
2 binding post
Special Features
quadrant scale
Material
steel
Nuclear Hardness Critical Feature
nonhardened
Style Designator
rectangular flush mtg
Supplementary Features
1.2 times the full scale value for conn to cur transformers
Fsc Application Data
test set,elect. equip.

Related Parts

This NSN group includes multiple components designed to meet specific performance and operational standards. Each listing provides detailed specs, functionality data, and replacement compatibility information:

Part Number Name
A96 0-500/600/1A Ammeter
M01055-E3390-Z-S41 Ammeter

FAQs

Find helpful answers about installation, operation, maintenance, compliance, and troubleshooting.

What is the FSCG of the NSN 6625-01-302-0890?
The FSCG of the NSN 6625-01-302-0890 is 6625
Does the NSN 6625-01-302-0890 have a Schedule B code assigned?
Yes, the Schedule B code is 9030908030
Does NSN 6625-01-302-0890 require demilitarization?
Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.
Does NSN 6625-01-302-0890 contain precious materials?
Item does not contain precious metal.
Does NSN 6625-01-302-0890 contain hazardous materials?
Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
When the NSN 6625-01-302-0890 was assigned to the Federal Catalog?
It was assigned 37 years ago, on Fri, Jun 9, 1989

Professional Distribution

Certified to meet the strict requirements of defense, aerospace, and hazardous materials distribution.

  • ITAR Registered
  • DDTC Registered
  • HAZMAT Certified
  • AS9120 Quality Standards
  • 100% Quality Inspections

You May Also Like

Browse other in-demand NSN parts sourced by professionals in defense, aerospace, and manufacturing sectors. Each component meets strict standards for quality and performance.

Pricing

Submit your request below and our team will respond quickly with up-to-date pricing, delivery estimates, and stock information:

ITAR Registered

Featured Parts

Explore our most requested parts, carefully selected based on customer demand and sourcing activity. Each listing provides current specifications, availability status, and item condition:

860528-0049
5905-00-814-9680
Resistor,fixed,wire Wound,induct
860528-0085
5905-00-879-3636
Resistor,fixed,wire Wound,induct
8605282
3020-00-572-1899
Spur Gear
8605283
3020-00-572-1900
Helical Gear
8605284
3020-00-572-1901
Worm Gear
860529
4730-00-069-3578
Pipe Flange
860529-1
5998-01-434-5643
Circuit Card Assembly
860529-2
5995-00-091-0391
Electrical Lead
860529-4
5995-00-106-2742
Electrical Lead
860529-6
5995-01-334-1395
Electrical Power Cable Assembly
860529-8
5995-00-294-3428
Electrical Lead
86053
1650-00-321-6230
Poppe Retaining Nut
86053-5000
6060-01-492-9816
Fiber Optic Plug Connector
860530
3120-00-492-9096
Sleeve Bearing
8605301LA
5962-01-372-5543
Memory Microcircuit