6625-01-122-2421

Find complete technical information, availability, and procurement data for: 6625-01-122-2421

DODParts.com distributes related products varnishes dopes paints, aircraft parts and consumables, electrical parts, fittings and other components for the aerospace and defense industries. Submit the short price quote form for NSN 6625-01-122-2421 to receive an up to date pricing and availability quote by email.

6625-01-122-2421
Federal Supply Group
Instruments and Laboratory Equipment
National Stock Number
6625-01-122-2421
Item Name Code
16450
Assigment Date
11/18/1981 (44 years ago)

4.640 inches maximum overall width, 100 single indicator single range scale division quantity, 4.090 inches maximum overall height, 2.645 inches maximum overall length, dc circuit current for which designed

Product Characteristics

Below you’ll find the complete technical specifications and performance data for this part, including material details and compliance information.

Circuit Current For Which Designed
dc
Overall Length
2.645 inches maximum
Overall Height
4.090 inches maximum
Overall Width
4.640 inches maximum
Scale Division Quantity
100 single indicator single range
Mounting Stud Length
0.480 inches minimum and 0.520 inches maximum
Environmental Protection
shock resistant and vibration resistant
Distance Between Mounting Facility Centers
3.490 inches minimum and 3.510 inches maximum
Indicator Type
dial w/pointer
Installation Design
panel
Mounting Arrangement Style
two hole/stud
Sensitivity Rating
100.0 microamperes
Dial Scale Marking Color
black single indicator single range
Accuracy In Percent
-2.0 to 2.0 at full scale single indicator single range
Panel For Which Designed
nonmagnetic
Meter Depth Behind Mounting Flange
1.370 inches maximum
Meter Body Diameter Behind Mounting Flange
2.790 inches maximum
Movement Type
moving coil, permanent magnet
Background Color
white single indicator single range
Pointer Color
black single indicator single range
Power Source
external
Mounting Facility Type And Quantity
2 threaded stud
Scale Graduation Type
linear single indicator single range
Measurement Range
-100.0 to 100.0 microamperes, dc single indicator single range
Circuit Construction Type
nonelectronic
Mounting Stud Diameter
0.138 inches nominal
Scale Selection Method
terminal
Features Provided
knife edge pointer and mirror scale and zero adjuster
Movement Suspension Method
taut band
Circuit Attachment Method And Quantity
2 threaded stud
Special Features
modified null meter
Special Markings
ccw w/line at full scale left; 1 pct cw w/line at full scale right
Material
plastic phenolic
Nuclear Hardness Critical Feature
nonhardened
Special Test Features
environmentals and dielectric test per ansi c39.1
Style Designator
rectangular flush mtg
Supplementary Features
800 vrms rated circuit to ground voltage
Fsc Application Data
test set,elect. equip.

Related Parts

This NSN group includes multiple components designed to meet specific performance and operational standards. Each listing provides detailed specs, functionality data, and replacement compatibility information:

Part Number Name
123-917-4 Ammeter
N5-4702-0100 Ammeter

FAQs

Find helpful answers about installation, operation, maintenance, compliance, and troubleshooting.

What is the FSCG of the NSN 6625-01-122-2421?
The FSCG of the NSN 6625-01-122-2421 is 6625
Does the NSN 6625-01-122-2421 have a Schedule B code assigned?
Yes, the Schedule B code is 9030908030
Does NSN 6625-01-122-2421 require demilitarization?
Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.
Does NSN 6625-01-122-2421 contain precious materials?
Item does not contain precious metal.
Does NSN 6625-01-122-2421 contain hazardous materials?
Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
When the NSN 6625-01-122-2421 was assigned to the Federal Catalog?
It was assigned 44 years ago, on Wed, Nov 18, 1981

Professional Distribution

Certified to meet the strict requirements of defense, aerospace, and hazardous materials distribution.

  • ITAR Registered
  • DDTC Registered
  • HAZMAT Certified
  • AS9120 Quality Standards
  • 100% Quality Inspections

You May Also Like

Browse other in-demand NSN parts sourced by professionals in defense, aerospace, and manufacturing sectors. Each component meets strict standards for quality and performance.

Pricing

Submit your request below and our team will respond quickly with up-to-date pricing, delivery estimates, and stock information:

ITAR Registered

Featured Parts

Explore our most requested parts, carefully selected based on customer demand and sourcing activity. Each listing provides current specifications, availability status, and item condition:

SN54H101J00
5962-00-551-8390
Digital Microcircuit
SN54H102J00
5962-00-348-5852
Digital Microcircuit
SN54H102N
5962-01-008-8778
Digital Microcircuit
SN54H103J
5962-00-139-2880
Digital Microcircuit
SN54H103J-00
5962-00-139-2880
Digital Microcircuit
SN54H103J10
5962-00-429-5774
Digital Microcircuit
SN54H103N
5962-00-429-5774
Digital Microcircuit
SN54H103Q
5962-01-027-5160
Digital Microcircuit
SN54H105
5962-00-428-2637
Digital Microcircuit
SN54H106J
5962-00-828-7298
Digital Microcircuit
SN54H106J-00
5962-00-146-8616
Digital Microcircuit
SN54H106J/883
5962-01-010-3488
Digital Microcircuit
SN54H108J
5962-00-320-6680
Digital Microcircuit
SN54H108J-00
5962-00-320-6680
Digital Microcircuit
SN54H108J00
5962-00-558-4601
Digital Microcircuit