7000P06901-7

View detailed technical data, stock status, and sourcing information for: 7000P06901-7

DODParts.com distributes related products varnishes dopes paints, aircraft parts and consumables, electrical parts, fittings and other components for the aerospace and defense industries. Submit the short price quote form for part 7000P06901-7 to receive an up to date pricing and availability quote by email.

7000P06901-7
Federal Supply Group
Instruments and Laboratory Equipment
National Stock Number
6625-01-049-3514
Item Name Code
61955
Assigment Date
10/16/1977 (48 years ago)

An electrically operated instrument which has a custom scale or digital readout display, but the unit of measurement given is not covered by a more specific item name. For items without a specified unit of measurement, see meter, arbitrary scale.

3000.0 dielectric withstanding voltage in volts, 0.720 inches minimum and 0.730 inches maximum center to center distance between mounting facilities parallel to width, 6.045 inches minimum and 6.055 inches maximum center to center distance between mounting facilities parallel to length, 7.730 inches maximum overall length, dc circuit current for which designed

Product Characteristics

Below you’ll find the complete technical specifications and performance data for this part, including material details and compliance information.

Circuit Current For Which Designed
dc
Dielectric Withstanding Voltage In Volts
3000.0
Overall Length
7.730 inches maximum
Center To Center Distance Between Mounting Facilities Parallel To Length
6.045 inches minimum and 6.055 inches maximum
Center To Center Distance Between Mounting Facilities Parallel To Width
0.720 inches minimum and 0.730 inches maximum
Overall Height
1.530 inches maximum
Overall Width
6.700 inches maximum
Mounting Hole Diameter
0.221 inches nominal
Scale Division Quantity
50 single indicator single range
Environmental Protection
airtight and dust resistant and fungus resistant and heat resistant and humidity resistant and shock resistant and vibration resistant and water resistant
Furnished Items And Quantity
nut 6; lockwasher 6; seal 1
Indicator Type
dial w/pointer
Installation Design
panel
Mounting Arrangement Style
four hole/stud rectangular/square
Sensitivity Rating
200.0 microamperes
Dial Scale Marking Color
black single indicator single range
Accuracy In Percent
-1.0 to 1.0 at full scale single indicator single range
Panel For Which Designed
magnetic
Meter Depth Behind Mounting Flange
5.770 inches maximum
Meter Body Width Behind Mounting Flange
5.450 inches maximum
Movement Type
moving coil, permanent magnet
Background Color
white single indicator single range
Pointer Color
red single indicator single range
Mounting Facility Type And Quantity
4 screw and 4 unthreaded hole
Scale Graduation Type
linear single indicator single range
Meter Body Height Behind Mounting Flange
1.225 inches maximum
Features Provided
magnetic shield and zero adjuster
Movement Suspension Method
jewel pivot base
Circuit Attachment Method And Quantity
2 threaded stud
Special Features
ruggedized
Special Markings
on back,+ and - marked for terminals
Material
plastic
Nuclear Hardness Critical Feature
nonhardened
Surface Treatment
paint
Special Test Features
complies with mil-m-10304
Style Designator
rectangular flush mtg
Fsc Application Data
test set,elect. equip.

Related Parts

This NSN group includes multiple components designed to meet specific performance and operational standards. Each listing provides detailed specs, functionality data, and replacement compatibility information:

Part Number Name
7000P06901-7 Special Scale Meter
9-2150-112 Special Scale Meter

FAQs

Find helpful answers about installation, operation, maintenance, compliance, and troubleshooting.

What is the FSCG of the NSN 6625-01-049-3514?
The FSCG of the NSN 6625-01-049-3514 is 6625
Does the NSN 6625-01-049-3514 have a Schedule B code assigned?
Yes, the Schedule B code is 9030908030
Does NSN 6625-01-049-3514 require demilitarization?
Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.
Does NSN 6625-01-049-3514 contain precious materials?
Item does not contain precious metal.
Does NSN 6625-01-049-3514 contain hazardous materials?
Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
When the NSN 6625-01-049-3514 was assigned to the Federal Catalog?
It was assigned 48 years ago, on Sun, Oct 16, 1977

Professional Distribution

Certified to meet the strict requirements of defense, aerospace, and hazardous materials distribution.

  • ITAR Registered
  • DDTC Registered
  • HAZMAT Certified
  • AS9120 Quality Standards
  • 100% Quality Inspections

You May Also Like

Browse other in-demand NSN parts sourced by professionals in defense, aerospace, and manufacturing sectors. Each component meets strict standards for quality and performance.

Pricing

Submit your request below and our team will respond quickly with up-to-date pricing, delivery estimates, and stock information:

ITAR Registered

Featured Parts

Explore our most requested parts, carefully selected based on customer demand and sourcing activity. Each listing provides current specifications, availability status, and item condition:

974-0044-00
5945-00-259-6438
Electromagnetic Relay
974-0045-00
5945-00-666-4213
Electromagnetic Relay
974-0046-00
5945-00-258-7651
Electromagnetic Relay
974-0048-000
5945-00-259-6575
Electromagnetic Relay
974-0058
6520-01-532-5240
Pulp Canal Plugger
974-0059
6520-01-532-5235
Pulp Canal Plugger
974-0063-00
5945-00-283-6609
Electromagnetic Relay
974-0064-00
5945-00-295-4686
Electromagnetic Relay
974-0065-00
5945-00-644-5180
Electromagnetic Relay
974-0077-010
5945-00-402-1292
Electromagnetic Relay
974-008-1
5325-01-290-8214
Retaining Ring
974-0082-050
5945-01-057-7430
Electromagnetic Relay
974-0082-110
5945-01-131-5677
Electromagnetic Relay
974-0083-030
5945-00-253-0239
Electromagnetic Relay
974-0085-011
5945-00-521-2107
Electromagnetic Relay