6625-01-012-3262

Find complete technical information, availability, and procurement data for: 6625-01-012-3262

DODParts.com distributes related products varnishes dopes paints, aircraft parts and consumables, electrical parts, fittings and other components for the aerospace and defense industries. Submit the short price quote form for NSN 6625-01-012-3262 to receive an up to date pricing and availability quote by email.

6625-01-012-3262
Federal Supply Group
Instruments and Laboratory Equipment
National Stock Number
6625-01-012-3262
Item Name Code
61955
Assigment Date
11/09/1975 (50 years ago)

An electrically operated instrument which has a custom scale or digital readout display, but the unit of measurement given is not covered by a more specific item name. For items without a specified unit of measurement, see meter, arbitrary scale.

0.725 inches nominal center to center distance between mounting facilities parallel to width, dc circuit current for which designed, 1500.0 dielectric withstanding voltage in volts, 6.050 inches nominal center to center distance between mounting facilities parallel to length, 7.730 inches maximum overall length

Product Characteristics

Below you’ll find the complete technical specifications and performance data for this part, including material details and compliance information.

Circuit Current For Which Designed
dc
Dielectric Withstanding Voltage In Volts
1500.0
Overall Length
7.730 inches maximum
Center To Center Distance Between Mounting Facilities Parallel To Length
6.050 inches nominal
Center To Center Distance Between Mounting Facilities Parallel To Width
0.725 inches nominal
Overall Height
1.530 inches maximum
Overall Width
6.700 inches maximum
Mounting Hole Diameter
0.220 inches nominal
Scale Division Quantity
25 single indicator 1st range
Environmental Protection
cold resistant and dripproof and heat resistant and shock resistant and vibration resistant
Furnished Items And Quantity
mtg hdw 4; term. hdw 2
Indicator Type
dial w/pointer
Installation Design
panel
Mounting Arrangement Style
four hole/stud rectangular/square
Sensitivity Rating
200.0 microamperes
Dial Scale Marking Color
black single indicator all ranges
Accuracy In Percent
-2.0 to 2.0 at full scale single indicator all ranges
Panel For Which Designed
magnetic
Meter Depth Behind Mounting Flange
5.770 inches maximum
Meter Body Width Behind Mounting Flange
5.450 inches maximum
Movement Type
moving coil, permanent magnet
Background Color
white single indicator all ranges
Pointer Color
black single indicator all ranges
Scale Marking
feet; tons; tank 7-109-0-w
Mounting Facility Type And Quantity
4 screw and 4 unthreaded hole
Scale Graduation Type
nonlinear single indicator 2nd range
Scale Graduation Type
linear single indicator 1st range
Meter Body Height Behind Mounting Flange
1.225 inches maximum
Features Provided
magnetic shield and zero adjuster
Criticality Code Justification
feat
Movement Suspension Method
jewel pivot base
Circuit Attachment Method And Quantity
2 threaded stud
Special Features
full scale values: 26.14 feet and 1342.56 tons
Special Markings
feet on ft scale,@tons on ton scale
Material
steel
Nuclear Hardness Critical Feature
nonhardened
Surface Treatment
enamel
Special Test Features
meets mil-m-10304 requirements
Style Designator
rectangular flush mtg
Supplementary Features
vertical mount
Fsc Application Data
test set,elect. equip.

Related Parts

This NSN group includes multiple components designed to meet specific performance and operational standards. Each listing provides detailed specs, functionality data, and replacement compatibility information:

Part Number Name
3675008-013 Special Scale Meter
9-2150-094 Special Scale Meter

FAQs

Find helpful answers about installation, operation, maintenance, compliance, and troubleshooting.

What is the FSCG of the NSN 6625-01-012-3262?
The FSCG of the NSN 6625-01-012-3262 is 6625
Does the NSN 6625-01-012-3262 have a Schedule B code assigned?
Yes, the Schedule B code is 9030908030
Does NSN 6625-01-012-3262 require demilitarization?
Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.
Does NSN 6625-01-012-3262 contain precious materials?
Item does not contain precious metal.
Does NSN 6625-01-012-3262 contain hazardous materials?
Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
When the NSN 6625-01-012-3262 was assigned to the Federal Catalog?
It was assigned 50 years ago, on Sun, Nov 9, 1975

Professional Distribution

Certified to meet the strict requirements of defense, aerospace, and hazardous materials distribution.

  • ITAR Registered
  • DDTC Registered
  • HAZMAT Certified
  • AS9120 Quality Standards
  • 100% Quality Inspections

You May Also Like

Browse other in-demand NSN parts sourced by professionals in defense, aerospace, and manufacturing sectors. Each component meets strict standards for quality and performance.

Pricing

Submit your request below and our team will respond quickly with up-to-date pricing, delivery estimates, and stock information:

ITAR Registered

Featured Parts

Explore our most requested parts, carefully selected based on customer demand and sourcing activity. Each listing provides current specifications, availability status, and item condition:

146021A
6685-01-619-6579
Indicating Vacuum Gage
146022
3040-01-626-6356
Mechanical Drive Housing
1460225081
5330-01-201-4669
Packing Retainer
146023-0000
6150-01-575-5123
Electrical Lead
146023-01
3040-00-021-6814
Shaft Collar
146023-9999
6150-01-575-5120
Electrical Lead
1460230
5965-01-692-9062
Permanent Magnet Loudspeaker
1460235
6520-01-662-7619
Sleeves,barrier,curing Light,den
1460236
5998-01-692-9059
Circuit Card Assembly
1460237
6760-01-008-1844
Record Unit Adapter
146024
4720-01-314-2520
Nonmetallic Hose Assembly
146024-2222
6150-01-575-5142
Electrical Lead
146024-5555
6150-01-575-5119
Electrical Lead
1460240
5930-01-559-6277
Toggle Switch
146025-2
1660-01-028-4218
Rate Control Valve Assembly