6625-01-009-0730

Find complete technical information, availability, and procurement data for: 6625-01-009-0730

DODParts.com distributes related products varnishes dopes paints, aircraft parts and consumables, electrical parts, fittings and other components for the aerospace and defense industries. Submit the short price quote form for NSN 6625-01-009-0730 to receive an up to date pricing and availability quote by email.

6625-01-009-0730
Federal Supply Group
Instruments and Laboratory Equipment
National Stock Number
6625-01-009-0730
Item Name Code
61955
Assigment Date
09/04/1975 (50 years ago)

3.795 inches minimum and 3.815 inches maximum center to center distance between mounting facilities parallel to length, 0.740 inches minimum and 0.760 inches maximum center to center distance between mounting facilities parallel to width, dc circuit current for which designed, 4.180 inches maximum overall length, 1500.0 dielectric withstanding voltage in volts

Product Characteristics

Below you’ll find the complete technical specifications and performance data for this part, including material details and compliance information.

Circuit Current For Which Designed
dc
Dielectric Withstanding Voltage In Volts
1500.0
Overall Length
4.180 inches maximum
Center To Center Distance Between Mounting Facilities Parallel To Length
3.795 inches minimum and 3.815 inches maximum
Center To Center Distance Between Mounting Facilities Parallel To Width
0.740 inches minimum and 0.760 inches maximum
Overall Height
1.525 inches maximum
Overall Width
4.234 inches maximum
Mounting Hole Diameter
0.138 inches nominal
Scale Division Quantity
12 single indicator 2nd range
Scale Division Quantity
20 single indicator 1st range
Environmental Protection
humidity resistant and shock resistant and vibration resistant
Furnished Items And Quantity
holder,lamp2; nut 4; lockwasher 4
Indicator Type
dial w/pointer
Installation Design
panel
Mounting Arrangement Style
four hole/stud rectangular/square
Sensitivity Rating
100.0 microamperes
Dial Scale Marking Color
black single indicator all ranges
Accuracy In Percent
-2.0 to 2.0 at full scale single indicator all ranges
Panel For Which Designed
nonmagnetic
Meter Depth Behind Mounting Flange
2.546 inches maximum
Meter Body Width Behind Mounting Flange
3.450 inches maximum
Movement Type
moving magnet
Background Color
white single indicator all ranges
Pointer Color
black single indicator all ranges
Scale Marking
degrees; -5; -4; -3; -2; -1; 0; 1; 2; 3; 4; 5 and -180; -150; -120; -90; -60; -30; 0; 30; 60; 90; 120; 150; 180
Mounting Facility Type And Quantity
4 screw and 4 unthreaded hole
Scale Graduation Type
linear single indicator all ranges
Meter Body Height Behind Mounting Flange
1.525 inches maximum
Features Provided
knife edge pointer and magnetic shield and self-illumination facility
Circuit Attachment Method And Quantity
4 solder lug
Operating Voltage Rating In Volts
28.0 dc nominal
Material
aluminum
Nuclear Hardness Critical Feature
nonhardened
Surface Treatment
enamel
Style Designator
rectangular flush mtg
Fsc Application Data
test set,elect. equip.

Related Parts

This NSN group includes multiple components designed to meet specific performance and operational standards. Each listing provides detailed specs, functionality data, and replacement compatibility information:

Part Number Name
3163013-1 Special Scale Meter
561917-001 Special Scale Meter
9-1147-112 Special Scale Meter

FAQs

Find helpful answers about installation, operation, maintenance, compliance, and troubleshooting.

What is the FSCG of the NSN 6625-01-009-0730?
The FSCG of the NSN 6625-01-009-0730 is 6625
Does the NSN 6625-01-009-0730 have a Schedule B code assigned?
Yes, the Schedule B code is 9030908030
Does NSN 6625-01-009-0730 require demilitarization?
Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.
Does NSN 6625-01-009-0730 contain precious materials?
Item does not contain precious metal.
Does NSN 6625-01-009-0730 contain hazardous materials?
Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
When the NSN 6625-01-009-0730 was assigned to the Federal Catalog?
It was assigned 50 years ago, on Thu, Sep 4, 1975

Professional Distribution

Certified to meet the strict requirements of defense, aerospace, and hazardous materials distribution.

  • ITAR Registered
  • DDTC Registered
  • HAZMAT Certified
  • AS9120 Quality Standards
  • 100% Quality Inspections

You May Also Like

Browse other in-demand NSN parts sourced by professionals in defense, aerospace, and manufacturing sectors. Each component meets strict standards for quality and performance.

Pricing

Submit your request below and our team will respond quickly with up-to-date pricing, delivery estimates, and stock information:

ITAR Registered

Featured Parts

Explore our most requested parts, carefully selected based on customer demand and sourcing activity. Each listing provides current specifications, availability status, and item condition:

RX26631033
6150-01-556-4842
E Special Purpose Cable Assembly
RX26A
5120-00-224-3162
Open End Box Wrench
RX270P50801
5961-01-304-6692
Transistor
RX270P52101
5961-01-304-6695
Transistor
RX270P52203
5961-01-304-6899
Transistor
RX270P52301
5961-01-304-6702
Transistor
RX270P52401
5961-01-304-6699
Transistor
RX270P56301
5961-01-304-6694
Transistor
RX274P50401
5961-01-304-6709
Diode Semiconductor Device
RX274P51605
5961-01-304-6902
Diode Semiconductor Device
RX277-12
5985-01-563-4346
Antenna Subassembly
RX278-2
5985-01-574-0736
Mast
RX2800 I2
7035-01-594-3780
Automatic Data Processing Server
RX2800 I4
7035-01-674-4412
Automatic Data Processing Server
RX283D51002
5920-01-355-0289
Cartridge Fuse