22-370-015-3A

View detailed technical data, stock status, and sourcing information for: 22-370-015-3A

DODParts.com distributes related products varnishes dopes paints, aircraft parts and consumables, electrical parts, fittings and other components for the aerospace and defense industries. Submit the short price quote form for part 22-370-015-3A to receive an up to date pricing and availability quote by email.

22-370-015-3A
Federal Supply Group
Instruments and Laboratory Equipment
National Stock Number
6625-00-933-1252
Item Name Code
16450
Assigment Date
02/24/1967 (59 years ago)

2.000 inches nominal center to center distance between mounting facilities parallel to length, 2.650 inches nominal overall height, 2.000 inches nominal center to center distance between mounting facilities parallel to width, dc circuit current for which designed, 2.110 inches minimum and 2.140 inches maximum overall length

Product Characteristics

Below you’ll find the complete technical specifications and performance data for this part, including material details and compliance information.

Circuit Current For Which Designed
dc
Overall Length
2.110 inches minimum and 2.140 inches maximum
Center To Center Distance Between Mounting Facilities Parallel To Length
2.000 inches nominal
Center To Center Distance Between Mounting Facilities Parallel To Width
2.000 inches nominal
Overall Height
2.650 inches nominal
Overall Width
2.650 inches nominal
Mounting Hole Diameter
0.168 inches nominal
Scale Division Quantity
30 single indicator single range
Furnished Items And Quantity
term. hdw 2; shunt 1
Indicator Type
dial w/pointer
Installation Design
panel
Mounting Arrangement Style
four hole/stud rectangular/square
Sensitivity Rating
50.0 millivolts
Dial Scale Marking Color
black single indicator single range
Accuracy In Percent
-3.0 to 3.0 at full scale single indicator single range
Panel For Which Designed
nonmagnetic
Meter Depth Behind Mounting Flange
1.595 inches minimum and 1.640 inches maximum
Meter Body Diameter Behind Mounting Flange
2.235 inches minimum and 2.255 inches maximum
Movement Type
electrodynamometer
Background Color
white single indicator single range
Pointer Color
black single indicator single range
Power Source
external
Mounting Facility Type And Quantity
4 unthreaded hole
Scale Graduation Type
linear single indicator single range
Measurement Range
+0.0 to 30.0 amperes single indicator single range
Circuit Construction Type
nonelectronic
Features Provided
external shunting and luminous scale marking
Movement Suspension Method
jewel pivot base
Circuit Attachment Method And Quantity
2 threaded stud
Special Features
shunt: 50 mv,30 amp
Special Markings
prop amps; green band from 14 to 18 amps
Nuclear Hardness Critical Feature
nonhardened
Style Designator
rectangular flush mtg
Fsc Application Data
test set,elect. equip.

Related Parts

This NSN group includes multiple components designed to meet specific performance and operational standards. Each listing provides detailed specs, functionality data, and replacement compatibility information:

Part Number Name
22-370-015-3A Ammeter
50-380086-3 Ammeter
FLD1B20828-3 Ammeter

FAQs

Find helpful answers about installation, operation, maintenance, compliance, and troubleshooting.

What is the FSCG of the NSN 6625-00-933-1252?
The FSCG of the NSN 6625-00-933-1252 is 6625
Does the NSN 6625-00-933-1252 have a Schedule B code assigned?
Yes, the Schedule B code is 9030908030
Does NSN 6625-00-933-1252 require demilitarization?
Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.
Does NSN 6625-00-933-1252 contain precious materials?
Item does not contain precious metal.
Does NSN 6625-00-933-1252 contain hazardous materials?
Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
When the NSN 6625-00-933-1252 was assigned to the Federal Catalog?
It was assigned 59 years ago, on Fri, Feb 24, 1967

Professional Distribution

Certified to meet the strict requirements of defense, aerospace, and hazardous materials distribution.

  • ITAR Registered
  • DDTC Registered
  • HAZMAT Certified
  • AS9120 Quality Standards
  • 100% Quality Inspections

You May Also Like

Browse other in-demand NSN parts sourced by professionals in defense, aerospace, and manufacturing sectors. Each component meets strict standards for quality and performance.

Pricing

Submit your request below and our team will respond quickly with up-to-date pricing, delivery estimates, and stock information:

ITAR Registered

Featured Parts

Explore our most requested parts, carefully selected based on customer demand and sourcing activity. Each listing provides current specifications, availability status, and item condition:

1672849-100
5841-01-225-7896
Simulator Trailer Test
167285
3130-01-291-7267
Bearing Unit Housing
1672854-001
5950-00-351-0359
Pulse Transformer
1672856
4923-00-760-9571
Test Chamber Adapter
167286
5999-01-217-8703
Electrical Contact
167287-001
5962-01-251-3651
Digital Microcircuit
1672875
3110-00-155-6612
Cylindrical Roller Bearing
1672877
3120-00-287-6714
Sleeve Bearing
1672879
5330-00-359-4366
Plain Encased Seal
1672881
5330-00-252-2374
Preformed Packing
1672888
9505-00-596-1648
Nonelectrical Wire
1672893
6545-01-722-5070
Austere Ta Medical Equipment Set
1672896
6515-01-723-5404
Oxygen Concentrator
16729
5110-00-204-0726
Hand File
16729-0
5905-01-115-0085