SM-B-527554-2

View detailed technical data, stock status, and sourcing information for: SM-B-527554-2

DODParts.com distributes related products varnishes dopes paints, aircraft parts and consumables, electrical parts, fittings and other components for the aerospace and defense industries. Submit the short price quote form for part SM-B-527554-2 to receive an up to date pricing and availability quote by email.

SM-B-527554-2
Federal Supply Group
Instruments and Laboratory Equipment
National Stock Number
6625-00-926-7691
Item Name Code
16449
Assigment Date
03/21/1967 (59 years ago)

1.775 inches nominal overall height, 1.312 inches nominal center to center distance between mounting facilities parallel to length, 1.312 inches nominal center to center distance between mounting facilities parallel to width, 1.490 inches nominal overall length, dc circuit current for which designed

Product Characteristics

Below you’ll find the complete technical specifications and performance data for this part, including material details and compliance information.

Circuit Current For Which Designed
dc
Overall Length
1.490 inches nominal
Center To Center Distance Between Mounting Facilities Parallel To Length
1.312 inches nominal
Center To Center Distance Between Mounting Facilities Parallel To Width
1.312 inches nominal
Overall Height
1.775 inches nominal
Overall Width
1.775 inches nominal
Mounting Hole Diameter
0.112 inches nominal
Scale Division Quantity
12 single indicator single range
Environmental Protection
dustproof
Furnished Items And Quantity
mounting hardware 4
Indicator Type
dial w/pointer
Installation Design
panel
Mounting Arrangement Style
four hole/stud rectangular/square
Sensitivity Rating
10000.0 ohms per volt
Dial Scale Marking Color
black single indicator single range
Accuracy In Percent
-5.0 to 5.0 at full scale single indicator single range
Meter Depth Behind Mounting Flange
1.170 inches nominal
Meter Body Diameter Behind Mounting Flange
1.000 inches nominal
Movement Type
moving coil, permanent magnet
Background Color
white single indicator single range
Pointer Color
black single indicator single range
Power Source
external
Mounting Facility Type And Quantity
4 unthreaded hole
Scale Graduation Type
linear single indicator single range
Measurement Range
+0.0 to 600.0 volts, dc single indicator single range
Scale Selection Method
terminal
Features Provided
zero adjuster
Movement Suspension Method
jewel pivot base
Circuit Attachment Method And Quantity
2 solder lug
Special Markings
yellow line at 300 v,green band from 210 v to 390 v
Material
plastic
Nuclear Hardness Critical Feature
nonhardened
Surface Treatment
enamel semigloss
Style Designator
rectangular flush mtg
Fsc Application Data
test set electronic

Related Parts

This NSN group includes multiple components designed to meet specific performance and operational standards. Each listing provides detailed specs, functionality data, and replacement compatibility information:

Part Number Name
SM-B-527554-2 Voltmeter

FAQs

Find helpful answers about installation, operation, maintenance, compliance, and troubleshooting.

What is the FSCG of the NSN 6625-00-926-7691?
The FSCG of the NSN 6625-00-926-7691 is 6625
Does the NSN 6625-00-926-7691 have a Schedule B code assigned?
Yes, the Schedule B code is 9030908030
Does NSN 6625-00-926-7691 require demilitarization?
Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.
Does NSN 6625-00-926-7691 contain precious materials?
Item does not contain precious metal.
Does NSN 6625-00-926-7691 contain hazardous materials?
Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
When the NSN 6625-00-926-7691 was assigned to the Federal Catalog?
It was assigned 59 years ago, on Tue, Mar 21, 1967

Professional Distribution

Certified to meet the strict requirements of defense, aerospace, and hazardous materials distribution.

  • ITAR Registered
  • DDTC Registered
  • HAZMAT Certified
  • AS9120 Quality Standards
  • 100% Quality Inspections

You May Also Like

Browse other in-demand NSN parts sourced by professionals in defense, aerospace, and manufacturing sectors. Each component meets strict standards for quality and performance.

Pricing

Submit your request below and our team will respond quickly with up-to-date pricing, delivery estimates, and stock information:

ITAR Registered

Featured Parts

Explore our most requested parts, carefully selected based on customer demand and sourcing activity. Each listing provides current specifications, availability status, and item condition:

NDC00062-7102-01
6505-01-394-7676
Muromonab-Cd3 for Injection
NDC00062-7401-03
6505-01-348-7692
Epoetin Alfa Injection
NDC00064-1000-01
6505-01-536-6251
Papain and Urea Ointment
NDC00064-3884-04
6505-01-115-9932
Lanolated Mineral Oil Lotion
NDC00064-3885-08
6505-01-229-7673
Lanolated Mineral Oil Lotion
NDC00065-0023-15
6505-01-063-8635
Carbachol Intraocular Injection
NDC00065-0085-15
6505-01-533-1574
Naphazoline Hydrochloride and Ph
NDC00065-0092-23
6505-01-534-3445
Fluorescein Injection
NDC00065-0092-65
6505-01-098-9623
Fluorescein Injection
NDC00065-0192-31
6505-01-692-7584
Contact Lens Lubricating and Rew
NDC00065-0245-05
6505-01-229-3844
Betaxolol Hydrochloride Ophthalm
NDC00065-0245-10
6505-01-227-1545
Betaxolol Hydrochloride Ophthalm
NDC00065-0246-05
6505-01-335-9706
Betaxolol Hydrochloride Ophthalm
NDC00065-0246-20
6505-01-345-6086
Betaxolol Hydrochloride Ophthalm
NDC00065-0271-05
6505-01-459-0420
Olopatadine Hydroch