MK777-114

View detailed technical data, stock status, and sourcing information for: MK777-114

DODParts.com distributes related products varnishes dopes paints, aircraft parts and consumables, electrical parts, fittings and other components for the aerospace and defense industries. Submit the short price quote form for part MK777-114 to receive an up to date pricing and availability quote by email.

MK777-114
Federal Supply Group
Instruments and Laboratory Equipment
National Stock Number
6625-00-585-8199
Item Name Code
00794
Assigment Date
01/01/1963 (63 years ago)

A circular shaped item with an aperture manufactured to predetermined dimensions, constructed with a rectangular cross section that may be solid, with joint, or in a helical form that facilitates spiral wrap installation. It prevents seal extrusion under pressure and is designed to fit on the down-pressure side of a gland groove with a packing, preformed or o-ring.

2.370 inches nominal overall height, 1.860 inches nominal center to center distance between mounting facilities parallel to width, 1.860 inches nominal center to center distance between mounting facilities parallel to length, 2.715 inches nominal overall length, 2.370 inches nominal overall width

Product Characteristics

Below you’ll find the complete technical specifications and performance data for this part, including material details and compliance information.

Overall Length
2.715 inches nominal
Center To Center Distance Between Mounting Facilities Parallel To Length
1.860 inches nominal
Center To Center Distance Between Mounting Facilities Parallel To Width
1.860 inches nominal
Overall Height
2.370 inches nominal
Overall Width
2.370 inches nominal
Furnished Items And Quantity
shunt 1
Installation Design
panel
Mounting Arrangement Style
four hole/stud rectangular/square
Sensitivity Rating
1.0 milliamperes
Accuracy In Percent
-1.0 to 1.0 at full scale single indicator all ranges
Meter Depth Behind Mounting Flange
1.220 inches nominal
Meter Body Diameter Behind Mounting Flange
2.260 inches nominal
Movement Type
moving coil, permanent magnet
Mounting Facility Type And Quantity
4 threaded hole
Measurement Range
-150.0 to 150.0 amperes, dc single indicator 1st range
Measurement Range
-30.0 to 30.0 volts, dc single indicator 2nd range
Scale Selection Method
switch
Circuit Attachment Method And Quantity
4 threaded stud
Special Features
pointer yellow flourescent
Material
plastic
Style Designator
round flush mtg w/4 tabs
Reference Number Differentiating Characteristics
as differentiated by scale range,marking and pointer collor

Replaces National Stock Numbers

Below is a list of NSNs that have been officially superseded by this NSN:

NSN Name Date
6625-01-394-9498 No Name Available 01/01/1996

Related Parts

This NSN group includes multiple components designed to meet specific performance and operational standards. Each listing provides detailed specs, functionality data, and replacement compatibility information:

Part Number Name
231-003 Multimeter
3341B5725 Multimeter
FLDF-P-20340-1 Multimeter
MK777-114 Multimeter

FAQs

Find helpful answers about installation, operation, maintenance, compliance, and troubleshooting.

What is the FSCG of the NSN 6625-00-585-8199?
The FSCG of the NSN 6625-00-585-8199 is 6625
Does the NSN 6625-00-585-8199 have a Schedule B code assigned?
Yes, the Schedule B code is 9030908030
Does NSN 6625-00-585-8199 require demilitarization?
Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.
Does NSN 6625-00-585-8199 contain precious materials?
Item does not contain precious metal.
Does NSN 6625-00-585-8199 contain hazardous materials?
Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
When the NSN 6625-00-585-8199 was assigned to the Federal Catalog?
It was assigned 63 years ago, on Tue, Jan 1, 1963

Professional Distribution

Certified to meet the strict requirements of defense, aerospace, and hazardous materials distribution.

  • ITAR Registered
  • DDTC Registered
  • HAZMAT Certified
  • AS9120 Quality Standards
  • 100% Quality Inspections

You May Also Like

Browse other in-demand NSN parts sourced by professionals in defense, aerospace, and manufacturing sectors. Each component meets strict standards for quality and performance.

Pricing

Submit your request below and our team will respond quickly with up-to-date pricing, delivery estimates, and stock information:

ITAR Registered

Featured Parts

Explore our most requested parts, carefully selected based on customer demand and sourcing activity. Each listing provides current specifications, availability status, and item condition:

BENNY/BLACK/L
8415-01-623-6359
Parachutists' Helmet
BENNY/BLACK/M
8415-01-623-6357
Parachutists' Helmet
BENNY/BLACK/XL
8415-01-623-4752
Parachutists' Helmet
BENNY/BLACK/XXL
8415-01-623-6344
Parachutists' Helmet
BENNY/HALFSHELL/BLACK
8415-01-623-6358
Parachutists' Helmet
BENNY/HALFSHELL/BLACK/XL
8415-01-623-6060
Parachutists' Helmet
BENNY/HALFSHELL/BLACK/XXL
8415-01-623-6059
Parachutists' Helmet
BENNY-L-REPL. LINER
8415-01-622-0264
Parachutists' Helmet
BENNY-M-REPL. LINER
8415-01-622-0271
Parachutists' Helmet
BENNY-XL-REPL. LINER
8415-01-622-0262
Parachutists' Helmet
BENNY-XXL-REPL. LINER
8415-01-622-0272
Parachutists' Helmet
BENOXYL
6505-01-149-3565
Benzoyl Peroxide Lotion
BENOXYL LOTION
6505-01-149-3565
Benzoyl Peroxide Lotion
BENSEAL
9390-01-395-8276
Bentonite
BENTSON
6515-01-565-8055
Cardiovascular Cathet Guide Wire