245-1112P1

View detailed technical data, stock status, and sourcing information for: 245-1112P1

DODParts.com distributes related products varnishes dopes paints, aircraft parts and consumables, electrical parts, fittings and other components for the aerospace and defense industries. Submit the short price quote form for part 245-1112P1 to receive an up to date pricing and availability quote by email.

245-1112P1
Federal Supply Group
Instruments and Laboratory Equipment
National Stock Number
6625-00-585-3795
Item Name Code
16449
Assigment Date
01/01/1963 (63 years ago)

"an electrically operated instrument having a zero point on its scale (usually located in the center thereof). It may not indicate units of electrical measurement. The value may be expressed by means of a pointer and calibrated dial or a digital readout display. When the indication shows zero, an electrical value of "zero" has been reached in the circuit. It is generally used in situations in which zero is the desired effect. Excludes:ammeter, galvanometer; meter, arbitary scale; and voltmeter."

0.500 inches nominal mounting stud length, dc circuit current for which designed, 2.650 inches maximum overall length, 10 single indicator single range scale division quantity, 3000.0 dielectric withstanding voltage in volts

Product Characteristics

Below you’ll find the complete technical specifications and performance data for this part, including material details and compliance information.

Circuit Current For Which Designed
dc
Dielectric Withstanding Voltage In Volts
3000.0
Overall Length
2.650 inches maximum
Scale Division Quantity
10 single indicator single range
Mounting Stud Length
0.500 inches nominal
Overall Diameter
2.695 inches maximum
Mounting Bolt Circle Diameter
2.440 inches nominal
Furnished Items And Quantity
washer 3,nuts 3
Indicator Type
dial w/pointer
Installation Design
panel
Mounting Arrangement Style
three hole/stud bolt circle
Sensitivity Rating
20000.0 ohms per volt
Dial Scale Marking Color
black single indicator single range
Accuracy In Percent
-2.0 to 2.0 at full scale single indicator single range
Meter Depth Behind Mounting Flange
1.600 inches maximum
Meter Body Diameter Behind Mounting Flange
2.210 inches maximum
Movement Type
moving coil, permanent magnet
Background Color
white single indicator single range
Pointer Color
black single indicator single range
Mounting Facility Type And Quantity
3 threaded stud
Scale Graduation Type
linear single indicator single range
Measurement Range
+0.0 to 10.0 volts, dc single indicator single range
Mounting Stud Diameter
0.125 inches nominal
Features Provided
zero adjuster
Movement Suspension Method
jewel pivot base
Circuit Attachment Method And Quantity
2 binding post
Nuclear Hardness Critical Feature
nonhardened
Style Designator
round semi-flush mtg
Fsc Application Data
test set,elect. equip.

Related Parts

This NSN group includes multiple components designed to meet specific performance and operational standards. Each listing provides detailed specs, functionality data, and replacement compatibility information:

Part Number Name
245-1112P1 Voltmeter

FAQs

Find helpful answers about installation, operation, maintenance, compliance, and troubleshooting.

What is the FSCG of the NSN 6625-00-585-3795?
The FSCG of the NSN 6625-00-585-3795 is 6625
Does the NSN 6625-00-585-3795 have a Schedule B code assigned?
Yes, the Schedule B code is 9030908030
Does NSN 6625-00-585-3795 require demilitarization?
Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.
Does NSN 6625-00-585-3795 contain precious materials?
Item does not contain precious metal.
Does NSN 6625-00-585-3795 contain hazardous materials?
Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
When the NSN 6625-00-585-3795 was assigned to the Federal Catalog?
It was assigned 63 years ago, on Tue, Jan 1, 1963

Professional Distribution

Certified to meet the strict requirements of defense, aerospace, and hazardous materials distribution.

  • ITAR Registered
  • DDTC Registered
  • HAZMAT Certified
  • AS9120 Quality Standards
  • 100% Quality Inspections

You May Also Like

Browse other in-demand NSN parts sourced by professionals in defense, aerospace, and manufacturing sectors. Each component meets strict standards for quality and performance.

Pricing

Submit your request below and our team will respond quickly with up-to-date pricing, delivery estimates, and stock information:

ITAR Registered

Featured Parts

Explore our most requested parts, carefully selected based on customer demand and sourcing activity. Each listing provides current specifications, availability status, and item condition:

82626-3
4130-01-134-7136
High Pressure Control Assembly
82626-4
5340-00-550-8942
Loop Clamp
82626-41R
5340-01-353-0183
Loop Clamp
82626-5
5340-00-550-8941
Loop Clamp
82626-6
5340-00-550-8937
Loop Clamp
82626-7
5340-00-550-8935
Loop Clamp
82626-8
5340-00-543-3950
Loop Clamp
82626-9
5340-00-550-8944
Loop Clamp
826260
5930-00-876-0527
Rotary Switch
8262610
5340-00-543-3951
Loop Clamp
8262624
2910-01-306-6832
Starting Aid Ether Parts Kit
826265
3120-01-555-3586
Sleeve Bearing Half
826267T2
5340-01-516-5249
Mounting Bracket
82626A10
5340-00-543-3951
Loop Clamp
82626A16
5340-00-551-6939
Loop Clamp