6201-3134389PC1

View detailed technical data, stock status, and sourcing information for: 6201-3134389PC1

DODParts.com distributes related products varnishes dopes paints, aircraft parts and consumables, electrical parts, fittings and other components for the aerospace and defense industries. Submit the short price quote form for part 6201-3134389PC1 to receive an up to date pricing and availability quote by email.

6201-3134389PC1
Federal Supply Group
Instruments and Laboratory Equipment
National Stock Number
6625-00-375-5429
Item Name Code
16450
Assigment Date
01/01/1963 (63 years ago)

An instrument which measures electrical potential and is calibrated in volts or any multiple and/or submultiple thereof. The value may be expressed by means of a pointer and calibrated dial or a digital readout display.

1.500 inches nominal center to center distance between mounting facilities parallel to width, dc circuit current for which designed, 2.562 inches nominal overall length, 1.500 inches nominal center to center distance between mounting facilities parallel to length, 2000.0 dielectric withstanding voltage in volts

Product Characteristics

Below you’ll find the complete technical specifications and performance data for this part, including material details and compliance information.

Circuit Current For Which Designed
dc
Dielectric Withstanding Voltage In Volts
2000.0
Overall Length
2.562 inches nominal
Center To Center Distance Between Mounting Facilities Parallel To Length
1.500 inches nominal
Center To Center Distance Between Mounting Facilities Parallel To Width
1.500 inches nominal
Scale Division Quantity
40 single indicator single range
Mounting Stud Length
0.375 inches nominal
Overall Diameter
3.500 inches nominal
Environmental Protection
dust resistant
Indicator Type
dial w/pointer
Installation Design
panel
Mounting Arrangement Style
four hole/stud rectangular/square
Dial Scale Marking Color
black single indicator single range
Accuracy In Percent
-2.0 to 2.0 at full scale single indicator single range
Panel For Which Designed
magnetic
Meter Depth Behind Mounting Flange
2.062 inches nominal
Meter Body Diameter Behind Mounting Flange
2.875 inches nominal
Movement Type
moving coil, permanent magnet
Background Color
white single indicator single range
Pointer Color
black single indicator single range
Power Source
external
Mounting Facility Type And Quantity
4 threaded stud
Scale Graduation Type
linear single indicator single range
Measurement Range
+0.0 to 40.0 amperes, dc single indicator single range
Circuit Construction Type
nonelectronic
Mounting Stud Diameter
0.250 inches nominal
Scale Selection Method
terminal
Features Provided
zero adjuster
Movement Suspension Method
jewel pivot base
Circuit Attachment Method And Quantity
2 threaded stud
Material
steel
Nuclear Hardness Critical Feature
nonhardened
Style Designator
round flush mtg
Fsc Application Data
test set,electronic equipment

Related Parts

This NSN group includes multiple components designed to meet specific performance and operational standards. Each listing provides detailed specs, functionality data, and replacement compatibility information:

FAQs

Find helpful answers about installation, operation, maintenance, compliance, and troubleshooting.

What is the FSCG of the NSN 6625-00-375-5429?
The FSCG of the NSN 6625-00-375-5429 is 6625
Does the NSN 6625-00-375-5429 have a Schedule B code assigned?
Yes, the Schedule B code is 9030908030
Does NSN 6625-00-375-5429 require demilitarization?
Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.
Does NSN 6625-00-375-5429 contain precious materials?
Item does not contain precious metal.
Does NSN 6625-00-375-5429 contain hazardous materials?
Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
When the NSN 6625-00-375-5429 was assigned to the Federal Catalog?
It was assigned 63 years ago, on Tue, Jan 1, 1963

Professional Distribution

Certified to meet the strict requirements of defense, aerospace, and hazardous materials distribution.

  • ITAR Registered
  • DDTC Registered
  • HAZMAT Certified
  • AS9120 Quality Standards
  • 100% Quality Inspections

You May Also Like

Browse other in-demand NSN parts sourced by professionals in defense, aerospace, and manufacturing sectors. Each component meets strict standards for quality and performance.

Pricing

Submit your request below and our team will respond quickly with up-to-date pricing, delivery estimates, and stock information:

ITAR Registered

Featured Parts

Explore our most requested parts, carefully selected based on customer demand and sourcing activity. Each listing provides current specifications, availability status, and item condition:

2B1270
5935-00-987-5911
Connector Adapter
2B12772-1
3010-00-828-1162
Nonvehicular Universal Joint
2B12899
5365-01-209-8324
Ring Spacer
2B12LT
6515-01-694-3641
Laparoscopic Trocar Sleeve
2B12TFA16L-0240
4720-01-434-4227
Nonmetallic Hose Assembly
2B13-2
4520-00-421-9661
Immer Electrical Heating Element
2B1302
6505-01-462-2118
Sodium Chloride Injection
2B1308
6505-01-139-2847
Sodium Chloride Injection
2B1309
6505-01-139-4083
Sodium Chloride Injection
2B1313Q
6505-01-462-2120
Sodium Chloride Injection
2B1314X
6505-01-462-2122
Sodium Chloride Injection
2B1315
5330-00-363-6508
Gasket
2B1320
5945-00-966-4567
Electromagnetic Relay
2B1321
6505-01-182-8012
Sodium Chloride Injection
2B1321Q
6505-01-182-8012
Sodium Chloride Injection