DODParts.com distributes related products varnishes dopes paints, aircraft parts and consumables, electrical parts, fittings and other components for the aerospace and defense industries. Submit the short price quote form for part 9-1147-074 to receive an up to date pricing and availability quote by email.
3.790 inches maximum overall length, dc circuit current for which designed, 1500.0 dielectric withstanding voltage in volts, 0.744 inches minimum and 0.756 inches maximum center to center distance between mounting facilities parallel to width, 3.799 inches minimum and 3.811 inches maximum center to center distance between mounting facilities parallel to length
Product Characteristics
Below you’ll find the complete technical specifications and performance data for this part, including material details and compliance information.
- Circuit Current For Which Designed
- dc
- Dielectric Withstanding Voltage In Volts
- 1500.0
- Overall Length
- 3.790 inches maximum
- Center To Center Distance Between Mounting Facilities Parallel To Length
- 3.799 inches minimum and 3.811 inches maximum
- Center To Center Distance Between Mounting Facilities Parallel To Width
- 0.744 inches minimum and 0.756 inches maximum
- Overall Height
- 1.525 inches maximum
- Overall Width
- 4.234 inches maximum
- Mounting Hole Diameter
- 0.138 inches nominal
- Environmental Protection
- shock resistant and vibration resistant and watertight
- Indicator Type
- dial w/pointer
- Installation Design
- panel
- Mounting Arrangement Style
- four hole/stud rectangular/square
- Sensitivity Rating
- 1.8 milliamperes and 18.5 milliamperes
- Dial Scale Marking Color
- black single indicator all ranges
- Accuracy In Percent
- -2.0 to 2.0 at full scale single indicator 2nd range
- Accuracy In Percent
- -2.0 to 2.0 at full scale single indicator 3rd range
- Accuracy In Percent
- -3.0 to 3.0 at full scale single indicator 1st range
- Accuracy In Percent
- -3.0 to 3.0 at full scale single indicator 4th range
- Meter Depth Behind Mounting Flange
- 2.525 inches minimum and 3.603 inches maximum
- Meter Body Width Behind Mounting Flange
- 3.450 inches maximum
- Movement Type
- moving coil, permanent magnet
- Background Color
- white single indicator all ranges
- Pointer Color
- black single indicator all ranges
- Power Source
- external
- Mounting Facility Type And Quantity
- 4 unthreaded hole
- Scale Graduation Type
- nonlinear single indicator all ranges
- Measurement Range
- +0.0 to 350.0 kilowatts single indicator 3rd range
- Measurement Range
- +0.0 to 800.0 kilowatts single indicator 4th range
- Measurement Range
- -10.0 to 0.0 decibels above or below one milliwatt single indicator 1st range
- Measurement Range
- -20.0/-10.0 decibels above or below one milliwatt single indicator 2nd range
- Scale Selection Method
- terminal
- Meter Body Height Behind Mounting Flange
- 1.525 inches maximum
- Features Provided
- knife edge pointer and magnetic shield and self-illumination facility and zero adjuster
- Movement Suspension Method
- jewel pivot base
- Circuit Attachment Method And Quantity
- 2 solder lug
- Special Features
- ruggedized and horizontal mounting
- Material
- aluminum
- Nuclear Hardness Critical Feature
- nonhardened
- Surface Treatment
- enamel
- Special Test Features
- drawing iaw mil-d-1000; shock and mositure resistant iaw mil-std-202; mark iaw mil-std-130
- Style Designator
- rectangular flush mtg
- Supplementary Features
- internal res upper scale 18 ohms porm 5 pct; lower scale 135 ohms porm 5 pct; response time 2 sec
- Fsc Application Data
- test set,elect. equip.
Related Parts
This NSN group includes multiple components designed to meet specific performance and operational standards. Each listing provides detailed specs, functionality data, and replacement compatibility information:
| Part Number | Name |
|---|---|
| 2920523-2 | Multiple Scale Meter |
| 562257-2 | Multiple Scale Meter |
| 9-1147-074 | Multiple Scale Meter |
FAQs
Find helpful answers about installation, operation, maintenance, compliance, and troubleshooting.
What is the FSCG of the NSN 6625-00-291-0900?
Does the NSN 6625-00-291-0900 have a Schedule B code assigned?
Does NSN 6625-00-291-0900 require demilitarization?
Does NSN 6625-00-291-0900 contain precious materials?
Does NSN 6625-00-291-0900 contain hazardous materials?
When the NSN 6625-00-291-0900 was assigned to the Federal Catalog?
Professional Distribution
Certified to meet the strict requirements of defense, aerospace, and hazardous materials distribution.
- ITAR Registered
- DDTC Registered
- HAZMAT Certified
- AS9120 Quality Standards
- 100% Quality Inspections
You May Also Like
Browse other in-demand NSN parts sourced by professionals in defense, aerospace, and manufacturing sectors. Each component meets strict standards for quality and performance.
Pricing
Submit your request below and our team will respond quickly with up-to-date pricing, delivery estimates, and stock information: