6625-00-178-9580

Find complete technical information, availability, and procurement data for: 6625-00-178-9580

DODParts.com distributes related products varnishes dopes paints, aircraft parts and consumables, electrical parts, fittings and other components for the aerospace and defense industries. Submit the short price quote form for NSN 6625-00-178-9580 to receive an up to date pricing and availability quote by email.

6625-00-178-9580
Federal Supply Group
Instruments and Laboratory Equipment
National Stock Number
6625-00-178-9580
Item Name Code
20901
Assigment Date
01/01/1961 (65 years ago)

+12.0 to 96.0 counterclockwise scale direction and range, nonlinear scale linearity, included probe handle, unable to decode case material, 1000.0 gauss minimum and 10000.0 gauss maximum flux density

Product Characteristics

Below you’ll find the complete technical specifications and performance data for this part, including material details and compliance information.

Scale Direction And Range
+12.0 to 96.0 counterclockwise
Scale Linearity
nonlinear
Case Material
unable to decode
Flux Density
1000.0 gauss minimum and 10000.0 gauss maximum
Probe Handle
included
Magnet Yoke Quantity
2
Magnet Gap Range Accommodated
+1.300 to 1.500 inches
Magnet Diameter Range Accommodated
+0.000 to 1.625 inches
Functional Classification
aa-5.6
Functional Description
portable,provides qualitative measurements of flux densities between pole faces of magnets employed in oscillatory circuits of x-band & s-band transmitters; calibrated directly in gauss units of flux density; c/o 2 milliammeters in series (a group meter & a probe meter),a rheostat,& associated shunts; probe meter is inserted between poles of magnet under test & indications are read on gauss meter; probe meter uses field of magnet under test to produce a deflection when a current is passed through its coil; current required to produce this reading is then a measure of flux density; controls & indicators are located on front panel
Entry Date
70-04-01
Reference Data And Literature
tm 11-2559 instruction book; an 16-35ts15-32 maintenance instruction; mfr(s) r/n ts-15a/ap
Relationship To Similar Equipment
interchangeable w/ 6625005192407,6625004740880,6625005552939
Reference Number Differentiating Characteristics
as manufactured by marion electrical instrument co

Replaces National Stock Numbers

Below is a list of NSNs that have been officially superseded by this NSN:

NSN Name Date
6625-00-405-6510 No Name Available 01/01/1963

Related Parts

This NSN group includes multiple components designed to meet specific performance and operational standards. Each listing provides detailed specs, functionality data, and replacement compatibility information:

Part Number Name
TS15AAP Fluxmeter

FAQs

Find helpful answers about installation, operation, maintenance, compliance, and troubleshooting.

What is the FSCG of the NSN 6625-00-178-9580?
The FSCG of the NSN 6625-00-178-9580 is 6625
Does the NSN 6625-00-178-9580 have a Schedule B code assigned?
Yes, the Schedule B code is 9030908030
Does NSN 6625-00-178-9580 require demilitarization?
Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.
Does NSN 6625-00-178-9580 contain precious materials?
Item does not contain precious metal.
Does NSN 6625-00-178-9580 contain hazardous materials?
Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
When the NSN 6625-00-178-9580 was assigned to the Federal Catalog?
It was assigned 65 years ago, on Sun, Jan 1, 1961

Professional Distribution

Certified to meet the strict requirements of defense, aerospace, and hazardous materials distribution.

  • ITAR Registered
  • DDTC Registered
  • HAZMAT Certified
  • AS9120 Quality Standards
  • 100% Quality Inspections

You May Also Like

Browse other in-demand NSN parts sourced by professionals in defense, aerospace, and manufacturing sectors. Each component meets strict standards for quality and performance.

Pricing

Submit your request below and our team will respond quickly with up-to-date pricing, delivery estimates, and stock information:

ITAR Registered

Featured Parts

Explore our most requested parts, carefully selected based on customer demand and sourcing activity. Each listing provides current specifications, availability status, and item condition:

1061907
4820-01-680-3563
Safety Relief Valve
1061908
6760-01-239-7657
Lens Cap
1061909
5325-01-456-8896
Retaining Ring
1061909-1
5310-00-085-6225
Flat Washer
10619091-1
5310-00-085-6225
Flat Washer
106191
1680-00-600-1402
Friction Lining
1061911
6150-01-510-1153
E Special Purpose Cable Assembly
10619141
5365-01-628-4463
Shim
1061916
3110-01-244-8665
Bearing Ball
1061918
3020-01-242-3118
Groove Pulley
1061919
3030-01-239-3679
V Belt
106192-1
5310-00-057-3103
Flat Washer
106192/SERIES 1
4320-01-266-1017
Centrifugal Pump Unit
106192 SERIES 100AB
4320-01-266-1017
Centrifugal Pump Unit
106192 W/ 3/4IN FLANGES
4320-00-019-7028
Centrifugal Pump Unit