6625-00-144-0106

Find complete technical information, availability, and procurement data for: 6625-00-144-0106

DODParts.com distributes related products varnishes dopes paints, aircraft parts and consumables, electrical parts, fittings and other components for the aerospace and defense industries. Submit the short price quote form for NSN 6625-00-144-0106 to receive an up to date pricing and availability quote by email.

6625-00-144-0106
Federal Supply Group
Instruments and Laboratory Equipment
National Stock Number
6625-00-144-0106
Item Name Code
16450
Assigment Date
01/01/1963 (63 years ago)

An instrument which measures electric current and is calibrated and marked in amperes or any multiple and/or submultiple thereof. The value may be expressed by means of a pointer and calibrated dial or a digital readout display. For current detecting type of devices, see galvanometer.

3.969 inches nominal overall height, 3.312 inches nominal center to center distance between mounting facilities parallel to width, dc circuit current for which designed, 2.781 inches nominal overall length, 3.625 inches nominal center to center distance between mounting facilities parallel to length

Product Characteristics

Below you’ll find the complete technical specifications and performance data for this part, including material details and compliance information.

Circuit Current For Which Designed
dc
Overall Length
2.781 inches nominal
Center To Center Distance Between Mounting Facilities Parallel To Length
3.625 inches nominal
Center To Center Distance Between Mounting Facilities Parallel To Width
3.312 inches nominal
Overall Height
3.969 inches nominal
Overall Width
4.219 inches nominal
Scale Division Quantity
60 single indicator single range
Mounting Stud Length
1.312 inches nominal
Furnished Items And Quantity
nuts 4
Indicator Type
dial w/pointer
Installation Design
panel
Mounting Arrangement Style
four hole/stud rectangular/square
Sensitivity Rating
50.0 millivolts
Dial Scale Marking Color
black single indicator single range
Accuracy In Percent
-2.0 to 2.0 at full scale single indicator single range
Panel For Which Designed
nonmagnetic
Meter Depth Behind Mounting Flange
1.625 inches nominal
Meter Body Diameter Behind Mounting Flange
3.750 inches nominal
Movement Type
moving coil, permanent magnet
Background Color
white single indicator single range
Pointer Color
black single indicator single range
Mounting Facility Type And Quantity
4 threaded stud
Scale Graduation Type
linear single indicator single range
Measurement Range
+0.0 to 3.0 amperes, dc single indicator single range
Circuit Construction Type
nonelectronic
Mounting Stud Diameter
0.138 inches nominal
Movement Suspension Method
jewel pivot base
Circuit Attachment Method And Quantity
2 threaded stud
Material
plastic
Nuclear Hardness Critical Feature
nonhardened
Style Designator
rectangular flush mtg
Fsc Application Data
test set,elect. equip.

Related Parts

This NSN group includes multiple components designed to meet specific performance and operational standards. Each listing provides detailed specs, functionality data, and replacement compatibility information:

Part Number Name
1160060 Ammeter
QX37 Ammeter

FAQs

Find helpful answers about installation, operation, maintenance, compliance, and troubleshooting.

What is the FSCG of the NSN 6625-00-144-0106?
The FSCG of the NSN 6625-00-144-0106 is 6625
Does the NSN 6625-00-144-0106 have a Schedule B code assigned?
Yes, the Schedule B code is 9030908030
Does NSN 6625-00-144-0106 require demilitarization?
Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.
Does NSN 6625-00-144-0106 contain precious materials?
Item does not contain precious metal.
Does NSN 6625-00-144-0106 contain hazardous materials?
Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
When the NSN 6625-00-144-0106 was assigned to the Federal Catalog?
It was assigned 63 years ago, on Tue, Jan 1, 1963

Professional Distribution

Certified to meet the strict requirements of defense, aerospace, and hazardous materials distribution.

  • ITAR Registered
  • DDTC Registered
  • HAZMAT Certified
  • AS9120 Quality Standards
  • 100% Quality Inspections

You May Also Like

Browse other in-demand NSN parts sourced by professionals in defense, aerospace, and manufacturing sectors. Each component meets strict standards for quality and performance.

Pricing

Submit your request below and our team will respond quickly with up-to-date pricing, delivery estimates, and stock information:

ITAR Registered

Featured Parts

Explore our most requested parts, carefully selected based on customer demand and sourcing activity. Each listing provides current specifications, availability status, and item condition:

AB2503E14
5305-00-177-5643
Machine Screw
AB2503F8
5305-00-877-4415
Machine Screw
AB2504F8
5305-00-670-4431
Machine Screw
AB2509
5330-01-007-4778
Preformed Packing
AB250SB25-1
5905-00-417-0839
Matched Resistor Set
AB2510
5910-00-515-2259
Electrolytic Fixed Capacitor
AB2513A10
5305-00-989-7435
Machine Screw
AB2520-1216D4
4820-00-968-5926
Valve Disk
AB2525
5910-00-139-2384
Electrolytic Fixed Capacitor
AB2528
5910-00-189-3314
Electrolytic Fixed Capacitor
AB2528E1
2915-00-774-6816
Fluid Filter Element
AB2533-A10
5305-01-409-0964
Machine Screw
AB2533-E5
5305-01-019-6496
Machine Screw
AB2533E4
5305-01-074-6074
Assembled Washer Screw
AB2533E7
5305-00-211-8162
Machine Screw