6625-00-069-5477

Find complete technical information, availability, and procurement data for: 6625-00-069-5477

DODParts.com distributes related products varnishes dopes paints, aircraft parts and consumables, electrical parts, fittings and other components for the aerospace and defense industries. Submit the short price quote form for NSN 6625-00-069-5477 to receive an up to date pricing and availability quote by email.

6625-00-069-5477
Federal Supply Group
Instruments and Laboratory Equipment
National Stock Number
6625-00-069-5477
Item Name Code
00357
Assigment Date
01/01/1961 (65 years ago)

A test instrument which is designed to give visual indications on an lcd display or a cathode ray tube of instantaneous values and variations in electrical voltage. It can also be used to indicate any quantity which can be converted into terms of electrical potential. It may include an integral pulse generator, the output of which can be used to trigger an external component; be triggered by pulses from an external source, or it may utilize an lcd display or a special type of multigun cathode ray tube and circuitry which permits a trace(s) to be sustained and displayed indefinitely, and the trace(s) may be erased when desired. For items which are not separable and operable when detached from equipment of which they are a part (built into operational equipment), see indicator (2) (as modified); monitor (as modified); and recorder (as modified). See also oscillograph.

50.0 hertz nominal frequency rating, 6.781 inches nominal overall height, ac current type, 16.750 inches nominal overall width, 18.375 inches nominal overall length

Product Characteristics

Below you’ll find the complete technical specifications and performance data for this part, including material details and compliance information.

Overall Length
18.375 inches nominal
Overall Height
6.781 inches nominal
Overall Width
16.750 inches nominal
Current Type
ac
Frequency Rating
50.0 hertz nominal
Voltage Rating
115.0 volts minimum and 230.0 volts maximum
Beam Quantity
1
Mounting Method
rack
Accuracy Range In Percent
-3.0 to 3.0
Screen Size
5.000 in.
Sweep Circuit Type
horizontal and vertical
Sweep Frequency Range
+5.000 to 10000.000 hertz
Single Trigger Sweep Duration
500.0 seconds nominal
Trigger Sweep Voltage Amplitude Rating
10.0 volts nominal
Vertical Deflection Sensitivity Voltage Rating
0.5 volts minimum rms per inch and 50.0 volts maximum rms per inch
Horizontal Deflection Sensitivity Voltage Rating
0.5 volts minimum rms per inch and 50.0 volts maximum rms per inch
Visual Modulation Sensitivity Voltage Rating
2.0 volts nominal
Visual Blanking Sensitivity Voltage Rating
20.0 volts nominal
X-Axis Frequency Response Rating
599.0 kilohertz nominal
Y-Axis Frequency Response Rating
500.0 kilohertz nominal
X-Axis Input Impedance Rating
1.0 megohms nominal
Y-Axis Input Impedance Rating
1.0 megohms nominal
Amplitude Calibrating Voltage Waveform
square wave
Calibrating Peak To Peak Amplitude
10.0 millivolts nominal
Measurement Range Quantity
16
Phase
single
Special Features
push button beam finder;internal graticule crt;common mode reflection below 40 db for 0.2 7v/cm to 0.2 v/cm,below 30 db from 0.5 v/cm to 20 v/cm; phase shift less than one degree up to 100 khz;balanced input on all ranges;front panel single sweep switch
Fsc Application Data
oscilloscopes,except specially designed

Related Parts

This NSN group includes multiple components designed to meet specific performance and operational standards. Each listing provides detailed specs, functionality data, and replacement compatibility information:

Part Number Name
4605004 Oscilloscope
ANUSM254 Oscilloscope
OS-185/U Oscilloscope

FAQs

Find helpful answers about installation, operation, maintenance, compliance, and troubleshooting.

What is the FSCG of the NSN 6625-00-069-5477?
The FSCG of the NSN 6625-00-069-5477 is 6625
Does the NSN 6625-00-069-5477 have a Schedule B code assigned?
Yes, the Schedule B code is 9030908030
Does NSN 6625-00-069-5477 require demilitarization?
Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.
Does NSN 6625-00-069-5477 contain precious materials?
Item does not contain precious metal.
Does NSN 6625-00-069-5477 contain hazardous materials?
Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
When the NSN 6625-00-069-5477 was assigned to the Federal Catalog?
It was assigned 65 years ago, on Sun, Jan 1, 1961

Professional Distribution

Certified to meet the strict requirements of defense, aerospace, and hazardous materials distribution.

  • ITAR Registered
  • DDTC Registered
  • HAZMAT Certified
  • AS9120 Quality Standards
  • 100% Quality Inspections

You May Also Like

Browse other in-demand NSN parts sourced by professionals in defense, aerospace, and manufacturing sectors. Each component meets strict standards for quality and performance.

Pricing

Submit your request below and our team will respond quickly with up-to-date pricing, delivery estimates, and stock information:

ITAR Registered

Featured Parts

Explore our most requested parts, carefully selected based on customer demand and sourcing activity. Each listing provides current specifications, availability status, and item condition:

ARINC404ATYPHDH4
3460-00-876-2922
Hold Down Machine Clamp
ARIST0C0RT
6505-00-221-3371
Triamcinolone Acetonide Ointment
ARIST0C0RTF0RTE
6505-00-227-9818
Triamcinolone Diacetate Injectab
ARISTA AH
6510-01-626-9614
Arista Ah
ARISTOCORT
6505-01-114-4805
Triamcinolone Acetonide Cream
ARISTOCORT FORTE
6505-00-981-7762
Triamcinolone Diacetate Injectab
ARISTOCORT FORTE PARENTERAL
6505-00-941-5159
Triamcinolone Diacetate Injectab
ARISTOCORT OINTMENT
6505-00-764-0598
Triamcinolone Acetonide Ointment
ARISTOCORT R
6505-01-138-5792
Triamcinolone Acetonide Cream
ARISTOCORT R OINTMENT
6505-01-113-9315
Triamcinolone Acetonide Ointment
ARISTOSPAN
6505-01-156-1663
Triamcinolone Hexacetonide Injec
ARIZN101126-1
6610-01-615-3085
Static Tube
ARIZN101126-2
6610-01-615-3095
Pitot Tube
ARIZN101126-3
6610-01-615-3066
Static Tube
ARIZN101126-4
6610-01-615-3076
Pitot Tube