131-015-0001

View detailed technical data, stock status, and sourcing information for: 131-015-0001

DODParts.com distributes related products varnishes dopes paints, aircraft parts and consumables, electrical parts, fittings and other components for the aerospace and defense industries. Submit the short price quote form for part 131-015-0001 to receive an up to date pricing and availability quote by email.

131-015-0001
Federal Supply Group
Instruments and Laboratory Equipment
National Stock Number
6625-00-068-4344
Item Name Code
16449
Assigment Date
01/01/1963 (63 years ago)

An instrument which measures electrical potential and is calibrated in volts or any multiple and/or submultiple thereof. The value may be expressed by means of a pointer and calibrated dial or a digital readout display.

2.400 inches nominal overall length, 3.560 inches nominal center to center distance between mounting facilities parallel to width, dc circuit current for which designed, 4.000 inches nominal center to center distance between mounting facilities parallel to length, 4.000 inches nominal overall height

Product Characteristics

Below you’ll find the complete technical specifications and performance data for this part, including material details and compliance information.

Circuit Current For Which Designed
dc
Overall Length
2.400 inches nominal
Center To Center Distance Between Mounting Facilities Parallel To Length
4.000 inches nominal
Center To Center Distance Between Mounting Facilities Parallel To Width
3.560 inches nominal
Overall Height
4.000 inches nominal
Overall Width
4.680 inches nominal
Scale Division Quantity
50 single indicator single range
Mounting Stud Length
0.680 inches nominal
Indicator Type
dial w/pointer
Installation Design
panel
Mounting Arrangement Style
four hole/stud rectangular/square
Sensitivity Rating
1000.0 ohms per volt
Dial Scale Marking Color
black single indicator single range
Accuracy In Percent
-2.0 to 2.0 at full scale single indicator single range
Meter Depth Behind Mounting Flange
1.760 inches nominal
Meter Body Diameter Behind Mounting Flange
2.750 inches nominal
Movement Type
moving coil, permanent magnet
Background Color
white single indicator single range
Pointer Color
black single indicator single range
Power Source
external
Mounting Facility Type And Quantity
4 threaded stud
Scale Graduation Type
linear single indicator single range
Measurement Range
+0.0 to 50.0 volts, dc single indicator single range
Mounting Stud Diameter
0.138 inches nominal
Features Provided
zero adjuster
Movement Suspension Method
jewel pivot base
Circuit Attachment Method And Quantity
2 threaded stud
Material
plastic
Style Designator
rectangular flush mtg
Fsc Application Data
test set,elect. equip.

Replaces National Stock Numbers

Below is a list of NSNs that have been officially superseded by this NSN:

NSN Name Date
6625-00-435-5142 No Name Available 04/16/1971
6625-00-786-8950 No Name Available 01/24/1974

Related Parts

This NSN group includes multiple components designed to meet specific performance and operational standards. Each listing provides detailed specs, functionality data, and replacement compatibility information:

Part Number Name
09930 Voltmeter
131-015-0001 Voltmeter
1329C Voltmeter
1329C0-50VDC Voltmeter
9930M0D1329RANGE Voltmeter

FAQs

Find helpful answers about installation, operation, maintenance, compliance, and troubleshooting.

What is the FSCG of the NSN 6625-00-068-4344?
The FSCG of the NSN 6625-00-068-4344 is 6625
Does the NSN 6625-00-068-4344 have a Schedule B code assigned?
Yes, the Schedule B code is 9030908030
Does NSN 6625-00-068-4344 require demilitarization?
Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.
Does NSN 6625-00-068-4344 contain precious materials?
Item does not contain precious metal.
Does NSN 6625-00-068-4344 contain hazardous materials?
Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
When the NSN 6625-00-068-4344 was assigned to the Federal Catalog?
It was assigned 63 years ago, on Tue, Jan 1, 1963

Professional Distribution

Certified to meet the strict requirements of defense, aerospace, and hazardous materials distribution.

  • ITAR Registered
  • DDTC Registered
  • HAZMAT Certified
  • AS9120 Quality Standards
  • 100% Quality Inspections

You May Also Like

Browse other in-demand NSN parts sourced by professionals in defense, aerospace, and manufacturing sectors. Each component meets strict standards for quality and performance.

Pricing

Submit your request below and our team will respond quickly with up-to-date pricing, delivery estimates, and stock information:

ITAR Registered

Featured Parts

Explore our most requested parts, carefully selected based on customer demand and sourcing activity. Each listing provides current specifications, availability status, and item condition:

9-11303-1
1560-00-573-3136
Control Column Connector
9-11325X
5930-00-272-1412
Sensitive Switch Housing
9-1133-1
5950-00-647-7609
Electrical Coil
9-1133-10
5950-01-221-3460
Electrical Coil
9-1133-2
5950-00-221-9071
Electrical Coil
9-1133-3
5950-00-236-0254
Electrical Coil
9-1133-4
5950-00-229-6199
Electrical Coil
9-1133-8
5950-00-964-4516
Electrical Coil
9-1135-2
5950-00-646-0307
Electrical Coil
9-1136
6625-00-313-8868
Spring
9-1136-079
6625-01-032-2008
Multiple Scale Meter
9-1138-1
5950-00-232-4866
Electrical Coil
9-114
3110-01-319-4870
Tapered Roller Bearing
9-1141
5342-00-387-4824
Bracket
9-1145-038
6625-00-166-5071
Ammeter