TF-614/USC-38(V)

View detailed technical data, stock status, and sourcing information for: TF-614/USC-38(V)

DODParts.com distributes related products varnishes dopes paints, aircraft parts and consumables, electrical parts, fittings and other components for the aerospace and defense industries. Submit the short price quote form for part TF-614/USC-38(V) to receive an up to date pricing and availability quote by email.

TF-614/USC-38(V)
Federal Supply Group
Electrical and Electronic Equipment Components
Federal Supply Classification
5950 Coils and Transformers
National Stock Number
5950-01-320-3930
Item Name Code
32496
Assigment Date
05/24/1990 (36 years ago)

An item of any peripheral shape having flanges or groove(s) on its outer perimeter to provide a self-retaining characteristic when inserted in a hole, clamp, or the like. Designed for the purpose of protecting and/or insulating wires, cables and other items passing through it. Excludes:bushing, nonmetallic; bumper; and insulator bushing.

not established reliability indicator, 7.000 inches nominal single mounting facility single center group center to center distance between mounting facilities parallel to length, 5.000 inches nominal single mounting facility single center group center to center distance between mounting facilities parallel to width, 0.406 inches nominal single group mounting hole diameter, 60.0 hertz nominal single component frequency rating

Product Characteristics

Below you’ll find the complete technical specifications and performance data for this part, including material details and compliance information.

Reliability Indicator
not established
Center To Center Distance Between Mounting Facilities Parallel To Length
7.000 inches nominal single mounting facility single center group
Center To Center Distance Between Mounting Facilities Parallel To Width
5.000 inches nominal single mounting facility single center group
Mounting Hole Diameter
0.406 inches nominal single group
Frequency Rating
60.0 hertz nominal single component
Input-Output Phase Relationship
single phase to single phase single component
Maximum Transformer Power Rating
1.3 kilovolt-ampere single component
Body Length
9.250 inches nominal
Body Width
6.844 inches nominal
Body Height
7.438 inches nominal
Inclosure Type
fully inclosed
Mounting Facility Quantity
4 single group
Mounting Method
unthreaded hole single group
Winding Function And Quantity
1 primary and 2 secondary single component
Winding Operating Current
2.9 amperes ac minimum and 3.2 amperes ac maximum single component single primary
Winding Operating Current
7.0 amperes ac nominal single component 2nd secondary
Winding Operating Current
9.0 amperes ac nominal single component 1st secondary
Winding Operating Voltage
104.00 ac volts minimum and 113.00 ac volts maximum single component 2nd secondary
Winding Operating Voltage
60.00 ac volts minimum and 65.00 ac volts maximum single component 1st secondary
Winding Operating Voltage
440.00 ac volts nominal single component single primary
Terminal Type And Quantity
7 solder stud

Related Parts

This NSN group includes multiple components designed to meet specific performance and operational standards. Each listing provides detailed specs, functionality data, and replacement compatibility information:

Part Number Name
244-001-421 Power Transformer
G225150-1 Power Transformer
TF-614/USC-38(V) Power Transformer

FAQs

Find helpful answers about installation, operation, maintenance, compliance, and troubleshooting.

What is the FSCG of the NSN 5950-01-320-3930?
The FSCG of the NSN 5950-01-320-3930 is 5950
Does NSN 5950-01-320-3930 require demilitarization?
Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.
Does NSN 5950-01-320-3930 contain precious materials?
Item does not contain precious metal.
Does NSN 5950-01-320-3930 contain hazardous materials?
Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
When the NSN 5950-01-320-3930 was assigned to the Federal Catalog?
It was assigned 36 years ago, on Thu, May 24, 1990

Professional Distribution

Certified to meet the strict requirements of defense, aerospace, and hazardous materials distribution.

  • ITAR Registered
  • DDTC Registered
  • HAZMAT Certified
  • AS9120 Quality Standards
  • 100% Quality Inspections

You May Also Like

Browse other in-demand NSN parts sourced by professionals in defense, aerospace, and manufacturing sectors. Each component meets strict standards for quality and performance.

Pricing

Submit your request below and our team will respond quickly with up-to-date pricing, delivery estimates, and stock information:

ITAR Registered

Featured Parts

Explore our most requested parts, carefully selected based on customer demand and sourcing activity. Each listing provides current specifications, availability status, and item condition:

668-027-001
5935-01-441-2205
Electrical Connector Retainer
668-0270-00
5950-00-845-1255
Reactor
668-0275-00
5950-00-679-9503
Reactor
668-0279-010
5950-01-321-4396
Electrical Coil
668-0280-00
5950-00-679-9508
Reactor
668-0282-00
5950-01-090-7247
Reactor
668-0285-010
5950-01-211-9234
Reactor
668-0292-010
5950-01-450-2748
Reactor
668-0300-00
5950-00-083-1622
Reactor
668-0322-000
5950-00-901-4316
Reactor
668-0340-010
5950-01-445-0599
Reactor
668-0341-00
5950-00-866-3618
Reactor
668-0360-010
5950-01-331-4092
Radio Frequency Coil
668-0361-010
5950-01-332-9447
Radio Frequency Coil
668-0365-010
5950-01-323-6664
Radio Frequency Coil