1. Home /
  2. Catalog /
  3. Coils and Transformers /
  4. 5950-01-309-6854

5950-01-309-6854

Find complete technical information, availability, and procurement data for: 5950-01-309-6854

DODParts.com distributes related products varnishes dopes paints, aircraft parts and consumables, electrical parts, fittings and other components for the aerospace and defense industries. Submit the short price quote form for NSN 5950-01-309-6854 to receive an up to date pricing and availability quote by email.

5950-01-309-6854
Federal Supply Group
Electrical and Electronic Equipment Components
Federal Supply Classification
5950 Coils and Transformers
National Stock Number
5950-01-309-6854
Item Name Code
32496
Assigment Date
10/21/1989 (36 years ago)

1.735 inches minimum and 1.765 inches maximum overall height, not established reliability indicator, 1.005 inches minimum and 1.035 inches maximum single mounting facility single center group center to center distance between mounting facilities parallel to width, 2.295 inches minimum and 2.325 inches maximum overall length, 1.795 inches minimum and 1.825 inches maximum single mounting facility single center group center to center distance between mounting facilities parallel to length

Product Characteristics

Below you’ll find the complete technical specifications and performance data for this part, including material details and compliance information.

Reliability Indicator
not established
Overall Length
2.295 inches minimum and 2.325 inches maximum
Center To Center Distance Between Mounting Facilities Parallel To Length
1.795 inches minimum and 1.825 inches maximum single mounting facility single center group
Center To Center Distance Between Mounting Facilities Parallel To Width
1.005 inches minimum and 1.035 inches maximum single mounting facility single center group
Overall Height
1.735 inches minimum and 1.765 inches maximum
Mounting Hole Diameter
0.164 inches minimum and 0.174 inches maximum single group
Frequency Rating
380.0 hertz minimum and 420.0 hertz maximum single component
Input-Output Phase Relationship
single phase to single phase single component
Body Width
1.505 inches minimum and 1.535 inches maximum
Maximum Operating Temp
130.0 celsius
Inclosure Type
fully inclosed
Mounting Facility Quantity
2 single group
Mounting Method
unthreaded hole single group
Winding Function And Quantity
1 primary and 1 secondary single component
Winding Operating Current
2.85 amperes ac nominal single component single secondary
Winding Operating Voltage
115.00 ac volts nominal single component single primary
Winding Operating Voltage
28.00 ac volts nominal single component single secondary
Test Data Document
"81349-mil-prf-27 specification (includes engineering type bulletins, brochures,etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type data on certain environmental and performance requirements and test conditions that are shown as "typical", "average", "nominal", etc.)."
Terminal Type And Quantity
5 turret
Specification/Standard Data
81349-mil-prf-27/342 government specification

Related Parts

This NSN group includes multiple components designed to meet specific performance and operational standards. Each listing provides detailed specs, functionality data, and replacement compatibility information:

Part Number Name
M27/342-12 Power Transformer

FAQs

Find helpful answers about installation, operation, maintenance, compliance, and troubleshooting.

What is the FSCG of the NSN 5950-01-309-6854?
The FSCG of the NSN 5950-01-309-6854 is 5950
Does NSN 5950-01-309-6854 require demilitarization?
Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.
Does NSN 5950-01-309-6854 contain precious materials?
Item does not contain precious metal.
Does NSN 5950-01-309-6854 contain hazardous materials?
Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
When the NSN 5950-01-309-6854 was assigned to the Federal Catalog?
It was assigned 36 years ago, on Sat, Oct 21, 1989

Professional Distribution

Certified to meet the strict requirements of defense, aerospace, and hazardous materials distribution.

  • ITAR Registered
  • DDTC Registered
  • HAZMAT Certified
  • AS9120 Quality Standards
  • 100% Quality Inspections

You May Also Like

Browse other in-demand NSN parts sourced by professionals in defense, aerospace, and manufacturing sectors. Each component meets strict standards for quality and performance.

Pricing

Submit your request below and our team will respond quickly with up-to-date pricing, delivery estimates, and stock information:

ITAR Registered

Featured Parts

Explore our most requested parts, carefully selected based on customer demand and sourcing activity. Each listing provides current specifications, availability status, and item condition:

AN/FAC-4(V)
5998-01-363-7724
Circuit Card Assembly
AN/FAC-4(V)1
6030-01-234-1203
Communications Term
AN/FAC-4(V)2
6030-01-234-1205
Communications Term
AN/FAC-4(V)3
6030-01-234-1207
Communications Term
AN/FAC-4(V)4
6030-01-234-1206
Communications Term
AN/FAC-4(V)5
6030-01-234-1204
Communications Term
AN/FAC-4(V)6
6030-01-234-1199
Communications Term
AN/FAC-4(V)7
6030-01-234-1200
Communications Term
AN/FAC-4(V)8
6030-01-234-1201
Communications Term
AN/FAC-4(V)9
6030-01-234-1202
Communications Term
AN/FAC-5
6030-01-234-1198
L Repeater Terminal
AN/FCA-30
6130-00-071-7088
Power Supply Set
AN/FCC-100(V)1X
5895-01-121-7079
Multiplexer Set
AN/FCC-100(V)2
5895-01-226-4034
Multiplexer Set
AN/FCC-100(V)7
5895-01-415-8662
Multiplexer Set