1. Home /
  2. Catalog /
  3. Coils and Transformers /
  4. 5950-01-255-6012

5950-01-255-6012

Find complete technical information, availability, and procurement data for: 5950-01-255-6012

DODParts.com distributes related products varnishes dopes paints, aircraft parts and consumables, electrical parts, fittings and other components for the aerospace and defense industries. Submit the short price quote form for NSN 5950-01-255-6012 to receive an up to date pricing and availability quote by email.

5950-01-255-6012
Federal Supply Group
Electrical and Electronic Equipment Components
Federal Supply Classification
5950 Coils and Transformers
National Stock Number
5950-01-255-6012
Item Name Code
00777
Assigment Date
05/22/1987 (39 years ago)

An electrical fitting with electrical contacts, constructed to be affixed to the end of a cable, conduit, coaxial line, cord or wiring for convenience in joining with other electrical connector(s) or printed wiring board and is not designed to be mounted on a bulkhead, chasses, panel, printed wiring board, or the like. Excludes:jack, telephone; jack, tip; plug, telephone; plug tip; insert, electrical connector; connector body (as modified); and socket, plug-in, electronic components. See also lead assembly, electrical; wiring harness (as modified); and cable assembly (as modified). For items without inserts, see shell, electrical connector.

4.750 inches maximum overall height, 4.500 inches nominal overall length, not established reliability indicator, 2.750 inches nominal single mounting facility single center group center to center distance between mounting facilities parallel to width, 4.000 inches nominal single mounting facility single center group center to center distance between mounting facilities parallel to length

Product Characteristics

Below you’ll find the complete technical specifications and performance data for this part, including material details and compliance information.

Reliability Indicator
not established
Overall Length
4.500 inches nominal
Center To Center Distance Between Mounting Facilities Parallel To Length
4.000 inches nominal single mounting facility single center group
Center To Center Distance Between Mounting Facilities Parallel To Width
2.750 inches nominal single mounting facility single center group
Overall Height
4.750 inches maximum
Mounting Slot Width
0.143 inches nominal single group
Frequency Rating
24.0 kilohertz minimum and 60.0 kilohertz maximum single component
Coil Form Type
solid single component
Winding Shielding Method
internal shield grounded to inclosure and core single component
Body Width
3.750 inches nominal
Inclosure Type
fully inclosed
Mounting Facility Quantity
4 single group
Mounting Method
slot single group
Winding Function And Quantity
1 primary and 1 secondary single component
Terminal Type And Quantity
6 threaded stud

Related Parts

This NSN group includes multiple components designed to meet specific performance and operational standards. Each listing provides detailed specs, functionality data, and replacement compatibility information:

Part Number Name
515-0123 Radio Frequency Transformer
SI-2702 Radio Frequency Transformer

FAQs

Find helpful answers about installation, operation, maintenance, compliance, and troubleshooting.

What is the FSCG of the NSN 5950-01-255-6012?
The FSCG of the NSN 5950-01-255-6012 is 5950
Does the NSN 5950-01-255-6012 have a Schedule B code assigned?
Yes, the Schedule B code is 8548900100
Does NSN 5950-01-255-6012 require demilitarization?
Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.
Does NSN 5950-01-255-6012 contain precious materials?
Item does not contain precious metal.
Does NSN 5950-01-255-6012 contain hazardous materials?
Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
When the NSN 5950-01-255-6012 was assigned to the Federal Catalog?
It was assigned 39 years ago, on Fri, May 22, 1987

Professional Distribution

Certified to meet the strict requirements of defense, aerospace, and hazardous materials distribution.

  • ITAR Registered
  • DDTC Registered
  • HAZMAT Certified
  • AS9120 Quality Standards
  • 100% Quality Inspections

You May Also Like

Browse other in-demand NSN parts sourced by professionals in defense, aerospace, and manufacturing sectors. Each component meets strict standards for quality and performance.

Pricing

Submit your request below and our team will respond quickly with up-to-date pricing, delivery estimates, and stock information:

ITAR Registered

Featured Parts

Explore our most requested parts, carefully selected based on customer demand and sourcing activity. Each listing provides current specifications, availability status, and item condition:

2-500-0011
5355-00-612-9119
Pointer Adapter
2.500-12UNC
5340-01-716-0300
Sealing Plug Assembly
2.500-16UN-3B
5310-01-658-1675
Hexagon Self-Locking Nut
2-500-3218
3030-00-758-0261
Printer Belt
2-500-3819A
5945-00-925-8143
Rod Armature
2-500-3819C
5945-00-925-8145
Rod Armature
2-500-3819D
5945-00-925-8146
Rod Armature
2-500-7
6680-01-139-3755
Liquid Level Switch
2.500-8UN-3AX5.000LG NICUAL
5305-01-655-7283
Socket Head Cap Screw
2.500 OD. X .75 0 ID. X 13.000L
9530-01-342-4720
Metal Bar
2-5000
6105-01-140-8695
Electric Motor Parts Kit
2-5000-100MM
6685-01-693-0465
Dial Indicating Pressure Gage
2-5000-1KPA
6685-01-572-1328
Dial Indicatin Differential Gage
2-5000-250PA
6685-01-308-3077
Dial Indicating Pressure Gage
2-5000-3KPA
6685-01-690-7451
Dial Indicatin Differential Gage