1. Home /
  2. Catalog /
  3. Coils and Transformers /
  4. 5950-01-254-2151

5950-01-254-2151

Find complete technical information, availability, and procurement data for: 5950-01-254-2151

DODParts.com distributes related products varnishes dopes paints, aircraft parts and consumables, electrical parts, fittings and other components for the aerospace and defense industries. Submit the short price quote form for NSN 5950-01-254-2151 to receive an up to date pricing and availability quote by email.

5950-01-254-2151
Federal Supply Group
Electrical and Electronic Equipment Components
Federal Supply Classification
5950 Coils and Transformers
National Stock Number
5950-01-254-2151
Item Name Code
00449
Assigment Date
05/03/1987 (39 years ago)

A coil or coils usually constructed with cores having low magnetic reluctance, whose primary purpose is to furnish an inductive impedance in power or audio frequency circuit ranging from zero to 20 kilohertz (kilocycles). Includes audio frequency and power filter chokes, audio reactors and swinging chokes. Does not include transformers or coils used above audio frequency range. Excludes:saturable reactor. For reactors with air cores, see coil (as modified).

single phase to single phase all components input-output phase relationship, not established reliability indicator, 0.187 inches nominal 3rd group mounting slot width, 0.187 inches nominal 1st group mounting hole diameter, 10.0 kilohertz nominal all components frequency rating

Product Characteristics

Below you’ll find the complete technical specifications and performance data for this part, including material details and compliance information.

Reliability Indicator
not established
Mounting Hole Diameter
0.187 inches nominal 1st group
Mounting Slot Width
0.187 inches nominal 3rd group
Frequency Rating
10.0 kilohertz nominal all components
Input-Output Phase Relationship
single phase to single phase all components
Winding Shielding Method
internal shield brought out to terminal 2nd component
Winding Shielding Method
internal shield brought out to terminal 3rd component
Body Length
4.750 inches nominal
Body Width
2.812 inches nominal
Body Height
3.570 inches nominal
Distance Between Mounting Facility Centers
4.218 inches nominal 2nd mounting facility single center group
Distance Between Mounting Facility Centers
4.500 inches nominal 3rd mounting facility single center group
Distance Between Mounting Facility Centers
5.375 inches nominal 1st mounting facility single center group
Inclosure Type
fully inclosed
Mounting Facility Quantity
2 all groupings
Mounting Method
unthreaded hole 1st group
Mounting Method
slot 3rd group
Mounting Method
threaded hole 2nd group
Rating Method
electrical all components all primary
Rating Method
electrical all components all secondary
Winding Function And Quantity
1 primary and 4 secondary 2nd component
Winding Function And Quantity
1 primary and 3 secondary 3rd component
Winding Function And Quantity
2 primary and 3 secondary 1st component
Nominal Thread Size
0.164 inches 2nd group
Winding Operating Current
1.2 amperes ac maximum 3rd component 2nd secondary
Winding Operating Current
3.0 amperes ac maximum 2nd component 4th secondary
Winding Operating Current
10.0 milliamperes ac maximum 3rd component 1st secondary
Winding Operating Current
50.0 milliamperes ac maximum 2nd component 1st secondary
Winding Operating Current
50.0 milliamperes ac maximum 2nd component 2nd secondary
Winding Operating Current
30.0 milliamperes ac maximum 1st component 4th secondary
Winding Operating Current
35.0 milliamperes ac maximum 2nd component 3rd secondary
Winding Operating Current
35.0 milliamperes ac maximum 3rd component 3rd secondary
Winding Operating Voltage
106.05 ac volts nominal 1st component 1st primary
Winding Operating Voltage
106.05 ac volts nominal 1st component 2nd primary
Winding Operating Voltage
106.05 ac volts nominal 1st component 2nd secondary
Winding Operating Voltage
149.88 ac volts nominal 2nd component 3rd secondary
Winding Operating Voltage
15.55 ac volts nominal 1st component 1st secondary
Winding Operating Voltage
15.55 ac volts nominal 3rd component single primary
Winding Operating Voltage
16.26 ac volts nominal 3rd component 1st secondary
Winding Operating Voltage
178.16 ac volts nominal and 195.84 ac volts nominal and 213.51 ac volts nominal 3rd component 4th secondary
Winding Operating Voltage
14.14 ac volts nominal 2nd component single primary
Winding Operating Voltage
530.25 ac volts nominal 1st component 3rd secondary
Winding Operating Voltage
6.01 ac volts nominal 2nd component 1st secondary
Winding Operating Voltage
6.01 ac volts nominal 2nd component 4th secondary
Winding Operating Voltage
70.70 ac volts nominal 2nd component 2nd secondary
Thread Series Designator
unc 2nd group
Terminal Type And Quantity
2 connector, receptacle

Related Parts

This NSN group includes multiple components designed to meet specific performance and operational standards. Each listing provides detailed specs, functionality data, and replacement compatibility information:

Part Number Name
321-18050-03 Transformer Assembly
984882-4B Transformer Assembly

FAQs

Find helpful answers about installation, operation, maintenance, compliance, and troubleshooting.

What is the FSCG of the NSN 5950-01-254-2151?
The FSCG of the NSN 5950-01-254-2151 is 5950
Does the NSN 5950-01-254-2151 have a Schedule B code assigned?
Yes, the Schedule B code is 8504900020
Does NSN 5950-01-254-2151 require demilitarization?
Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.
Does NSN 5950-01-254-2151 contain precious materials?
Item does not contain precious metal.
Does NSN 5950-01-254-2151 contain hazardous materials?
Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
When the NSN 5950-01-254-2151 was assigned to the Federal Catalog?
It was assigned 39 years ago, on Sun, May 3, 1987

Professional Distribution

Certified to meet the strict requirements of defense, aerospace, and hazardous materials distribution.

  • ITAR Registered
  • DDTC Registered
  • HAZMAT Certified
  • AS9120 Quality Standards
  • 100% Quality Inspections

You May Also Like

Browse other in-demand NSN parts sourced by professionals in defense, aerospace, and manufacturing sectors. Each component meets strict standards for quality and performance.

Pricing

Submit your request below and our team will respond quickly with up-to-date pricing, delivery estimates, and stock information:

ITAR Registered

Featured Parts

Explore our most requested parts, carefully selected based on customer demand and sourcing activity. Each listing provides current specifications, availability status, and item condition:

M8340105K7501FC
5905-01-266-1851
Film Fixed Resistor Network
M8340105K7501FG
5905-01-229-1375
Film Fixed Resistor Network
M8340105K7501GC
5905-01-338-0874
Film Fixed Resistor Network
M8340105K75R0GC
5905-01-359-0955
Film Fixed Resistor Network
M8340105K7681FG
5905-01-379-5716
Film Fixed Resistor Network
M8340105K7872FG
5905-01-390-6571
Film Fixed Resistor Network
M8340105K8200GC
5905-01-332-2593
Film Fixed Resistor Network
M8340105K8201GC
5905-01-295-8422
Film Fixed Resistor Network
M8340105K8202GG
5905-01-155-9758
Film Fixed Resistor Network
M8340105K8251FG
5905-01-378-7576
Film Fixed Resistor Network
M8340105K82R0GC
5905-01-462-3466
Film Fixed Resistor Network
M8340105K8662FG
5905-01-318-8041
Film Fixed Resistor Network
M8340105K9101GG
5905-01-245-9613
Film Fixed Resistor Network
M8340105K9530FG
5905-01-359-4785
Film Fixed Resistor Network
M8340105KA003GH
5905-01-409-1900
Film Fixed Resistor Network