DODParts.com distributes related products varnishes dopes paints, aircraft parts and consumables, electrical parts, fittings and other components for the aerospace and defense industries. Submit the short price quote form for part HY-292-7126-2 to receive an up to date pricing and availability quote by email.

HY-292-7126-2
Federal Supply Group
Electrical and Electronic Equipment Components
Federal Supply Classification
5950 Coils and Transformers
National Stock Number
5950-01-188-6229
Item Name Code
32496
Assigment Date
09/06/1984 (41 years ago)

A transformer consisting of one or more primary winding(s) and one or more secondary winding(s). It may be designed for direct connection to an alternating current source for purposes of changing the secondary volts and amperes or designed to eliminate metallic interconnection between circuits in an overall one to one voltage ratio, with or without additional output windings, or items designed to automatically maintain a constant output voltage within specified limits under varying input or load conditions. Also includes items having a provision for mechanically changing the turns ratio or inductive coupling in progressive increments by means of voltage taps, ratio adjuster, or devices oe similar design. For transformers having winding(s) common to both input and output circuits, see transformer (1), power, autotransformer. Excludes:transformer (1), pulse.

three phase to single phase and three phase to three phase single component input-output phase relationship, 380.0 hertz minimum and 420.0 hertz maximum single component frequency rating, not established reliability indicator, 2.000 inches nominal single mounting facility single center group center to center distance between mounting facilities parallel to width, 3.000 inches nominal single mounting facility single center group center to center distance between mounting facilities parallel to length

Product Characteristics

Below you’ll find the complete technical specifications and performance data for this part, including material details and compliance information.

Reliability Indicator
not established
Center To Center Distance Between Mounting Facilities Parallel To Length
3.000 inches nominal single mounting facility single center group
Center To Center Distance Between Mounting Facilities Parallel To Width
2.000 inches nominal single mounting facility single center group
Frequency Rating
380.0 hertz minimum and 420.0 hertz maximum single component
Input-Output Phase Relationship
three phase to single phase and three phase to three phase single component
Transformer Winding Connection Type
delta-wye
Winding Shielding Method
internal shield grounded to inclosure and core single component
Body Length
4.630 inches maximum
Body Width
2.650 inches maximum
Body Height
3.880 inches maximum
Maximum Operating Temp
75.0 celsius
Inclosure Type
fully inclosed
Mounting Facility Quantity
4 single group
Mounting Method
threaded hole single group
Winding Function And Quantity
1 primary and 5 secondary single component
Nominal Thread Size
0.138 inches single group
Winding Operating Current
1.6 amperes ac nominal single component 3rd secondary
Winding Operating Current
60.0 milliamperes ac nominal single component 1st secondary
Winding Operating Current
30.0 amperes ac nominal single component 4th secondary
Winding Operating Current
90.0 milliamperes ac nominal single component 2nd secondary
Winding Operating Voltage
15.50 ac volts nominal single component 3rd secondary
Winding Operating Voltage
175.00 ac volts nominal single component 2nd secondary
Winding Operating Voltage
176.00 ac volts minimum and 214.00 ac volts maximum single component single primary
Winding Operating Voltage
5.00 ac volts nominal single component 1st secondary
Winding Operating Voltage
8.30 ac volts nominal single component 4th secondary
Thread Series Designator
unc single group
Terminal Type And Quantity
17 tab, solder lug

Related Parts

This NSN group includes multiple components designed to meet specific performance and operational standards. Each listing provides detailed specs, functionality data, and replacement compatibility information:

Part Number Name
306302-000 Power Transformer
HY-292-7126-2 Power Transformer
TT2862A Power Transformer

FAQs

Find helpful answers about installation, operation, maintenance, compliance, and troubleshooting.

What is the FSCG of the NSN 5950-01-188-6229?
The FSCG of the NSN 5950-01-188-6229 is 5950
Does NSN 5950-01-188-6229 require demilitarization?
Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.
Does NSN 5950-01-188-6229 contain precious materials?
Item does not contain precious metal.
Does NSN 5950-01-188-6229 contain hazardous materials?
Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
When the NSN 5950-01-188-6229 was assigned to the Federal Catalog?
It was assigned 41 years ago, on Thu, Sep 6, 1984

Professional Distribution

Certified to meet the strict requirements of defense, aerospace, and hazardous materials distribution.

  • ITAR Registered
  • DDTC Registered
  • HAZMAT Certified
  • AS9120 Quality Standards
  • 100% Quality Inspections

You May Also Like

Browse other in-demand NSN parts sourced by professionals in defense, aerospace, and manufacturing sectors. Each component meets strict standards for quality and performance.

Pricing

Submit your request below and our team will respond quickly with up-to-date pricing, delivery estimates, and stock information:

ITAR Registered

Featured Parts

Explore our most requested parts, carefully selected based on customer demand and sourcing activity. Each listing provides current specifications, availability status, and item condition:

500-051NF3JU6-09
5935-01-535-1232
Electrical Connector Cover
500-051NF4JU6-02
5935-01-573-0591
Electrical Conne Cover and Guard
500-051NF5JU6-02
5935-01-534-1863
Electrical Conne Cover and Guard
500-051NF5JU6-09
5340-01-534-8875
Dust and Moistu Protective Cover
500-051NF5JU8-09
5935-01-535-0389
Electrical Connector Cover
500-051Y1JG6-06
5340-01-569-1981
Dust and Moisture Protective Cap
500-052-2-4
4920-01-575-0503
M Aircraft Jackpost
500-052-4-4
5935-01-551-4402
Electrical Connector Jackscrew
500-052-426
5331-01-728-7155
O-Ring
500-053
5950-00-003-7671
Reactor
500-053-00
5365-01-647-8774
Plate Spacer
500-055-10
4140-01-588-4689
Circulating Fan
500-055-2-2
5935-01-702-6459
Electrical Connector Jackscrew
500-056
5950-00-069-2505
Reactor
500-057
2825-00-379-3575
Blade Turbine Wheel