5950-01-145-6212

Find complete technical information, availability, and procurement data for: 5950-01-145-6212

DODParts.com distributes related products varnishes dopes paints, aircraft parts and consumables, electrical parts, fittings and other components for the aerospace and defense industries. Submit the short price quote form for NSN 5950-01-145-6212 to receive an up to date pricing and availability quote by email.

5950-01-145-6212
Federal Supply Group
Electrical and Electronic Equipment Components
Federal Supply Classification
5950 Coils and Transformers
National Stock Number
5950-01-145-6212
Item Name Code
00738
Assigment Date
01/14/1983 (43 years ago)

A transformer consisting of one or more primary winding(s) and one or more secondary winding(s). It may be designed for direct connection to an alternating current source for purposes of changing the secondary volts and amperes or designed to eliminate metallic interconnection between circuits in an overall one to one voltage ratio, with or without additional output windings, or items designed to automatically maintain a constant output voltage within specified limits under varying input or load conditions. Also includes items having a provision for mechanically changing the turns ratio or inductive coupling in progressive increments by means of voltage taps, ratio adjuster, or devices oe similar design. For transformers having winding(s) common to both input and output circuits, see transformer (1), power, autotransformer. Excludes:transformer (1), pulse.

single phase to single phase single component input-output phase relationship, 0.188 inches nominal single group mounting hole diameter, 380.0 hertz minimum and 420.0 hertz maximum single component frequency rating, not established reliability indicator, 1.940 inches nominal body length

Product Characteristics

Below you’ll find the complete technical specifications and performance data for this part, including material details and compliance information.

Reliability Indicator
not established
Mounting Hole Diameter
0.188 inches nominal single group
Frequency Rating
380.0 hertz minimum and 420.0 hertz maximum single component
Input-Output Phase Relationship
single phase to single phase single component
Body Length
1.940 inches nominal
Distance Between Mounting Facility Centers
2.410 inches nominal single mounting facility single center group
Inclosure Type
fully inclosed
Mounting Facility Quantity
2 single group
Mounting Method
bracket and unthreaded hole single group
Winding Function And Quantity
1 primary and 1 secondary single component
Winding Operating Current
5.0 milliamperes ac maximum single component single primary
Winding Operating Current
75.0 amperes ac maximum single component single secondary
Winding Operating Voltage
10.00 ac volts nominal single component single primary
Terminal Type And Quantity
2 ribbon and 2 tab, solder lug

Related Parts

This NSN group includes multiple components designed to meet specific performance and operational standards. Each listing provides detailed specs, functionality data, and replacement compatibility information:

Part Number Name
B847721-001 Current Transformer
B847721G1 Current Transformer
T6320 Current Transformer

FAQs

Find helpful answers about installation, operation, maintenance, compliance, and troubleshooting.

What is the FSCG of the NSN 5950-01-145-6212?
The FSCG of the NSN 5950-01-145-6212 is 5950
Does NSN 5950-01-145-6212 require demilitarization?
Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.
Does NSN 5950-01-145-6212 contain precious materials?
Item does not contain precious metal.
Does NSN 5950-01-145-6212 contain hazardous materials?
Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
When the NSN 5950-01-145-6212 was assigned to the Federal Catalog?
It was assigned 43 years ago, on Fri, Jan 14, 1983

Professional Distribution

Certified to meet the strict requirements of defense, aerospace, and hazardous materials distribution.

  • ITAR Registered
  • DDTC Registered
  • HAZMAT Certified
  • AS9120 Quality Standards
  • 100% Quality Inspections

You May Also Like

Browse other in-demand NSN parts sourced by professionals in defense, aerospace, and manufacturing sectors. Each component meets strict standards for quality and performance.

Pricing

Submit your request below and our team will respond quickly with up-to-date pricing, delivery estimates, and stock information:

ITAR Registered

Featured Parts

Explore our most requested parts, carefully selected based on customer demand and sourcing activity. Each listing provides current specifications, availability status, and item condition:

20-078-2B2
6150-01-025-3192
Conductor Bus
20-078-2C2
6150-01-256-4641
Conductor Bus
20-078-3B2
6150-01-256-6454
Conductor Bus
20-078-3C2
6150-01-256-4642
Conductor Bus
20-078-4B2
6150-01-025-3194
Conductor Bus
20-078-4C2
6150-01-256-4643
Conductor Bus
20-078-5A1
6150-01-612-3281
Conductor Bus
20-078-5B2
6150-01-028-0025
Conductor Bus
20-078-5C2
6150-01-256-4644
Conductor Bus
20-078-6B2
6150-01-256-4645
Conductor Bus
20-078-8A1
6150-01-612-3282
Conductor Bus
20-078-8B2
6150-01-026-4018
Conductor Bus
20-078-9C2
6150-01-256-6453
Conductor Bus
20-0783
4820-01-349-3814
Safety Relief Valve
20-07844
4820-00-019-0636
Valve Seat