20-000303-002
View detailed technical data, stock status, and sourcing information for: 20-000303-002
DODParts.com distributes related products varnishes dopes paints, aircraft parts and consumables, electrical parts, fittings and other components for the aerospace and defense industries. Submit the short price quote form for part 20-000303-002 to receive an up to date pricing and availability quote by email.
A transformer consisting of one or more primary winding(s) and one or more secondary winding(s). It may be designed for direct connection to an alternating current source for purposes of changing the secondary volts and amperes or designed to eliminate metallic interconnection between circuits in an overall one to one voltage ratio, with or without additional output windings, or items designed to automatically maintain a constant output voltage within specified limits under varying input or load conditions. Also includes items having a provision for mechanically changing the turns ratio or inductive coupling in progressive increments by means of voltage taps, ratio adjuster, or devices oe similar design. For transformers having winding(s) common to both input and output circuits, see transformer (1), power, autotransformer. Excludes:transformer (1), pulse.
not established reliability indicator, 1.688 inches nominal single mounting facility single center group center to center distance between mounting facilities parallel to length, moisture resistant and vibration resistant hazardous locations/environmental protection, 60.0 hertz nominal single component frequency rating, 1.438 inches nominal single mounting facility single center group center to center distance between mounting facilities parallel to width
Product Characteristics
Below you’ll find the complete technical specifications and performance data for this part, including material details and compliance information.
- Reliability Indicator
- not established
- Hazardous Locations/Environmental Protection
- moisture resistant and vibration resistant
- Center To Center Distance Between Mounting Facilities Parallel To Length
- 1.688 inches nominal single mounting facility single center group
- Center To Center Distance Between Mounting Facilities Parallel To Width
- 1.438 inches nominal single mounting facility single center group
- Frequency Rating
- 60.0 hertz nominal single component
- Input-Output Phase Relationship
- single phase to single phase single component
- Winding Shielding Method
- internal shield grounded to core single component
- Body Length
- 2.187 inches minimum and 2.312 inches maximum
- Body Width
- 1.874 inches minimum and 2.062 inches maximum
- Body Height
- 2.937 inches minimum and 3.125 inches maximum
- Maximum Operating Temp
- 130.0 celsius
- Inclosure Type
- hermetically sealed
- Mounting Facility Quantity
- 4 single group
- Mounting Method
- threaded stud single group
- Winding Function And Quantity
- 1 primary and 2 secondary single component
- Nominal Thread Size
- 0.138 inches single group
- Winding Operating Current
- 400.0 milliamperes dc maximum single component all secondary
- Winding Operating Voltage
- 115.00 ac volts nominal single component single primary
- Winding Operating Voltage
- 8.25 ac volts nominal and 12.00 ac volts nominal single component all secondary
- Special Features
- terminals 1 and 4 are split to make terminals 2 and 3 on the primary winding
- Test Data Document
- 06809-20-000303 drawing (this is the basic governing drawing, such as a contractor drawing, original equipment manufacturer drawing, etc.; excludes any specification, standard or other document that may be referenced in a basic governing drawing)
- Thread Series Designator
- unc single group
- Terminal Type And Quantity
- 10 turret
Related Parts
This NSN group includes multiple components designed to meet specific performance and operational standards. Each listing provides detailed specs, functionality data, and replacement compatibility information:
| Part Number | Name |
|---|---|
| 20-000303-002 | Power Transformer |
FAQs
Find helpful answers about installation, operation, maintenance, compliance, and troubleshooting.
What is the FSCG of the NSN 5950-01-067-0996?
Does NSN 5950-01-067-0996 require demilitarization?
Does NSN 5950-01-067-0996 contain precious materials?
Does NSN 5950-01-067-0996 contain hazardous materials?
When the NSN 5950-01-067-0996 was assigned to the Federal Catalog?
Professional Distribution
Certified to meet the strict requirements of defense, aerospace, and hazardous materials distribution.
- ITAR Registered
- DDTC Registered
- HAZMAT Certified
- AS9120 Quality Standards
- 100% Quality Inspections