1. Home /
  2. Catalog /
  3. Coils and Transformers /
  4. 5950-00-972-9362

5950-00-972-9362

Find complete technical information, availability, and procurement data for: 5950-00-972-9362

DODParts.com distributes related products varnishes dopes paints, aircraft parts and consumables, electrical parts, fittings and other components for the aerospace and defense industries. Submit the short price quote form for NSN 5950-00-972-9362 to receive an up to date pricing and availability quote by email.

5950-00-972-9362
Federal Supply Group
Electrical and Electronic Equipment Components
Federal Supply Classification
5950 Coils and Transformers
National Stock Number
5950-00-972-9362
Item Name Code
32496
Assigment Date
01/01/1962 (64 years ago)

1.188 inches nominal single mounting facility single center group center to center distance between mounting facilities parallel to width, not established reliability indicator, 2.750 inches nominal overall height, 1.188 inches nominal single mounting facility single center group center to center distance between mounting facilities parallel to length, 400.0 hertz nominal single component frequency rating

Product Characteristics

Below you’ll find the complete technical specifications and performance data for this part, including material details and compliance information.

Reliability Indicator
not established
Center To Center Distance Between Mounting Facilities Parallel To Length
1.188 inches nominal single mounting facility single center group
Center To Center Distance Between Mounting Facilities Parallel To Width
1.188 inches nominal single mounting facility single center group
Overall Height
2.750 inches nominal
Frequency Rating
400.0 hertz nominal single component
Input-Output Phase Relationship
single phase to single phase single component
Winding Shielding Method
core grounded and brought out to terminal and internal shield brought out to terminal single component
Body Length
1.563 inches minimum and 1.625 inches maximum
Body Width
1.563 inches minimum and 1.625 inches maximum
Inclosure Type
hermetically sealed
Mounting Facility Quantity
4 single group
Mounting Method
threaded stud single group
Winding Function And Quantity
1 primary and 3 secondary single component
Nominal Thread Size
0.138 inches single group
Winding Operating Current
208.0 milliamperes ac maximum single component 1st secondary
Winding Operating Current
115.0 milliamperes ac maximum single component 2nd secondary
Winding Operating Current
9.0 milliamperes ac maximum single component 3rd secondary
Winding Power Rating
2.0 watts single component 3rd secondary
Winding Power Rating
3.0 watts single component 2nd secondary
Winding Power Rating
5.0 watts single component 1st secondary
Winding Operating Voltage
109.00 ac volts nominal and 121.00 ac volts nominal and 230.00 ac volts nominal single component 3rd secondary
Winding Operating Voltage
115.00 ac volts nominal single component single primary
Winding Operating Voltage
26.00 ac volts nominal single component 2nd secondary
Winding Operating Voltage
24.00 ac volts nominal single component 1st secondary
Thread Series Designator
unc single group
Terminal Type And Quantity
14 wire hook

Related Parts

This NSN group includes multiple components designed to meet specific performance and operational standards. Each listing provides detailed specs, functionality data, and replacement compatibility information:

Part Number Name
P1-14406 Power Transformer

FAQs

Find helpful answers about installation, operation, maintenance, compliance, and troubleshooting.

What is the FSCG of the NSN 5950-00-972-9362?
The FSCG of the NSN 5950-00-972-9362 is 5950
Does NSN 5950-00-972-9362 require demilitarization?
Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.
Does NSN 5950-00-972-9362 contain precious materials?
Precious metal content is unknown
Does NSN 5950-00-972-9362 contain hazardous materials?
Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
When the NSN 5950-00-972-9362 was assigned to the Federal Catalog?
It was assigned 64 years ago, on Mon, Jan 1, 1962

Professional Distribution

Certified to meet the strict requirements of defense, aerospace, and hazardous materials distribution.

  • ITAR Registered
  • DDTC Registered
  • HAZMAT Certified
  • AS9120 Quality Standards
  • 100% Quality Inspections

You May Also Like

Browse other in-demand NSN parts sourced by professionals in defense, aerospace, and manufacturing sectors. Each component meets strict standards for quality and performance.

Pricing

Submit your request below and our team will respond quickly with up-to-date pricing, delivery estimates, and stock information:

ITAR Registered

Featured Parts

Explore our most requested parts, carefully selected based on customer demand and sourcing activity. Each listing provides current specifications, availability status, and item condition:

8520473-111
5962-01-398-5130
Digital Microcircuit
8520473-115
5962-01-398-5131
Digital Microcircuit
8520473-117
5962-01-400-0912
Digital Microcircuit
8520473-125
5962-01-454-3947
Microcircuit Assembly
8520474
7025-01-600-9871
Data Server 2u Nrp
8520475
7025-01-601-0031
Data Server 3u Nrp
8520477
5895-01-604-0841
S Mk21 Enet Daq Nrp
8520478
5998-01-601-0036
Nrp,cca,ntds-E,pcie
8520479
5998-01-601-0037
Cca Irig-B Nrp
852048
3020-01-177-6827
Ratchet Wheel
8520481
5998-01-601-0035
Cca Nic 6-Sfp Nrp
8520482
5895-01-601-0642
Towed Array Ass Nrp
8520483
6130-01-604-0790
Power Supply
8520484
5998-01-600-9869
Nrp,cca,adapter,lan
8520485
5998-01-600-9870
Nrp,cca,adapter,lan