DODParts.com distributes related products varnishes dopes paints, aircraft parts and consumables, electrical parts, fittings and other components for the aerospace and defense industries. Submit the short price quote form for NSN 5950-00-813-5699 to receive an up to date pricing and availability quote by email.

5950-00-813-5699
Federal Supply Group
Electrical and Electronic Equipment Components
Federal Supply Classification
5950 Coils and Transformers
National Stock Number
5950-00-813-5699
Item Name Code
32496
Assigment Date
03/25/1968 (58 years ago)

3.000 inches nominal single mounting facility single center group center to center distance between mounting facilities parallel to length, 50.0 hertz minimum and 400.0 hertz maximum single component frequency rating, single phase to single phase single component input-output phase relationship, 2.437 inches nominal single mounting facility single center group center to center distance between mounting facilities parallel to width, not established reliability indicator

Product Characteristics

Below you’ll find the complete technical specifications and performance data for this part, including material details and compliance information.

Reliability Indicator
not established
Center To Center Distance Between Mounting Facilities Parallel To Length
3.000 inches nominal single mounting facility single center group
Center To Center Distance Between Mounting Facilities Parallel To Width
2.437 inches nominal single mounting facility single center group
Frequency Rating
50.0 hertz minimum and 400.0 hertz maximum single component
Input-Output Phase Relationship
single phase to single phase single component
Winding Shielding Method
internal shield grounded to inclosure and core single component
Body Length
3.930 inches nominal
Body Width
3.370 inches nominal
Body Height
4.120 inches nominal
Inclosure Type
hermetically sealed
Mounting Facility Quantity
4 single group
Mounting Method
threaded stud single group
Winding Function And Quantity
1 primary and 4 secondary single component
Thread Quantity Per Inch
32 single group
Nominal Thread Size
0.190 inches single group
Winding Operating Current
2.0 amperes dc maximum single component 4th secondary
Winding Operating Current
10.0 milliamperes dc maximum single component 3rd secondary
Winding Operating Current
100.0 milliamperes dc maximum single component 2nd secondary
Winding Operating Current
120.0 milliamperes dc maximum single component 1st secondary
Winding Operating Voltage
155.00 ac volts nominal single component 3rd secondary
Winding Operating Voltage
115.00 ac volts nominal single component single primary
Winding Operating Voltage
32.00 ac volts nominal single component 4th secondary
Winding Operating Voltage
37.50 ac volts nominal single component 2nd secondary
Winding Operating Voltage
6.00 ac volts nominal single component 1st secondary
Thread Series Designator
unf single group
Terminal Type And Quantity
11 solder stud

Related Parts

This NSN group includes multiple components designed to meet specific performance and operational standards. Each listing provides detailed specs, functionality data, and replacement compatibility information:

Part Number Name
3480029-1 Power Transformer

FAQs

Find helpful answers about installation, operation, maintenance, compliance, and troubleshooting.

What is the FSCG of the NSN 5950-00-813-5699?
The FSCG of the NSN 5950-00-813-5699 is 5950
Does NSN 5950-00-813-5699 require demilitarization?
Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.
Does NSN 5950-00-813-5699 contain precious materials?
Precious metal content is unknown
Does NSN 5950-00-813-5699 contain hazardous materials?
Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
When the NSN 5950-00-813-5699 was assigned to the Federal Catalog?
It was assigned 58 years ago, on Mon, Mar 25, 1968

Professional Distribution

Certified to meet the strict requirements of defense, aerospace, and hazardous materials distribution.

  • ITAR Registered
  • DDTC Registered
  • HAZMAT Certified
  • AS9120 Quality Standards
  • 100% Quality Inspections

You May Also Like

Browse other in-demand NSN parts sourced by professionals in defense, aerospace, and manufacturing sectors. Each component meets strict standards for quality and performance.

Pricing

Submit your request below and our team will respond quickly with up-to-date pricing, delivery estimates, and stock information:

ITAR Registered

Featured Parts

Explore our most requested parts, carefully selected based on customer demand and sourcing activity. Each listing provides current specifications, availability status, and item condition:

D225K5K0
5905-00-259-9230
Adjustable Resistor
D225K5R0
5905-00-107-8979
Adjustable Resistor
D226
1670-01-547-6915
Parachute Toggle
D226-10078-1
5120-00-117-2342
Rigging Pin Set
D2260
5985-01-438-1459
Antenna
D226196-9
6145-00-170-5274
Wire Braid
D2262
5950-00-224-6982
Reactor-Transformer
D226240
5950-00-224-6982
Reactor-Transformer
D2263
5342-00-791-5936
Cover as Ventilator
D2263-23
5977-01-380-4312
Electrical Conta Holder Assembly
D22635PJ
4320-00-036-0702
Needle Valve
D2263A
2920-00-847-0857
Ignition System Distributor
D2263AA
2920-00-847-0857
Ignition System Distributor
D2264 NO 6+H198
4520-01-485-1961
Warm Air Heating Syst Humidifier
D22641HP
3040-01-268-9774
Manual Control Lever