1. Home /
  2. Catalog /
  3. Coils and Transformers /
  4. 5950-00-660-4825

5950-00-660-4825

Find complete technical information, availability, and procurement data for: 5950-00-660-4825

DODParts.com distributes related products varnishes dopes paints, aircraft parts and consumables, electrical parts, fittings and other components for the aerospace and defense industries. Submit the short price quote form for NSN 5950-00-660-4825 to receive an up to date pricing and availability quote by email.

5950-00-660-4825
Federal Supply Group
Electrical and Electronic Equipment Components
Federal Supply Classification
5950 Coils and Transformers
National Stock Number
5950-00-660-4825
Item Name Code
32496
Assigment Date
01/01/1963 (63 years ago)

1.750 inches nominal single mounting facility single center group center to center distance between mounting facilities parallel to width, not established reliability indicator, single phase to single phase single component input-output phase relationship, 2.125 inches nominal single mounting facility single center group center to center distance between mounting facilities parallel to length, 55.0 hertz minimum and 65.0 hertz maximum single component frequency rating

Product Characteristics

Below you’ll find the complete technical specifications and performance data for this part, including material details and compliance information.

Reliability Indicator
not established
Center To Center Distance Between Mounting Facilities Parallel To Length
2.125 inches nominal single mounting facility single center group
Center To Center Distance Between Mounting Facilities Parallel To Width
1.750 inches nominal single mounting facility single center group
Frequency Rating
55.0 hertz minimum and 65.0 hertz maximum single component
Input-Output Phase Relationship
single phase to single phase single component
Winding Shielding Method
internal shield grounded to inclosure and core single component
Body Length
2.750 inches nominal
Body Width
2.375 inches nominal
Body Height
3.812 inches nominal
Inclosure Type
hermetically sealed
Mounting Facility Quantity
4 single group
Mounting Method
threaded stud single group
Winding Function And Quantity
1 primary and 4 secondary single component
Thread Quantity Per Inch
32 single group
Nominal Thread Size
0.138 inches single group
Winding Operating Current
1.0 amperes ac maximum single component 1st secondary
Winding Operating Current
1.1 amperes ac maximum single component 2nd secondary
Winding Operating Current
1.1 amperes ac maximum single component 3rd secondary
Winding Operating Current
1.1 amperes ac maximum single component 4th secondary
Winding Operating Voltage
120.00 ac volts nominal single component single primary
Winding Operating Voltage
6.40 ac volts nominal single component 1st secondary
Winding Operating Voltage
5.50 ac volts nominal single component 2nd secondary
Winding Operating Voltage
5.50 ac volts nominal single component 3rd secondary
Winding Operating Voltage
5.50 ac volts nominal single component 4th secondary
Thread Series Designator
unc single group
Terminal Type And Quantity
10 tab, solder lug

Related Parts

This NSN group includes multiple components designed to meet specific performance and operational standards. Each listing provides detailed specs, functionality data, and replacement compatibility information:

Part Number Name
S292-6019G1 Power Transformer

FAQs

Find helpful answers about installation, operation, maintenance, compliance, and troubleshooting.

What is the FSCG of the NSN 5950-00-660-4825?
The FSCG of the NSN 5950-00-660-4825 is 5950
Does NSN 5950-00-660-4825 require demilitarization?
Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.
Does NSN 5950-00-660-4825 contain precious materials?
Precious metal content is unknown
Does NSN 5950-00-660-4825 contain hazardous materials?
Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
When the NSN 5950-00-660-4825 was assigned to the Federal Catalog?
It was assigned 63 years ago, on Tue, Jan 1, 1963

Professional Distribution

Certified to meet the strict requirements of defense, aerospace, and hazardous materials distribution.

  • ITAR Registered
  • DDTC Registered
  • HAZMAT Certified
  • AS9120 Quality Standards
  • 100% Quality Inspections

You May Also Like

Browse other in-demand NSN parts sourced by professionals in defense, aerospace, and manufacturing sectors. Each component meets strict standards for quality and performance.

Pricing

Submit your request below and our team will respond quickly with up-to-date pricing, delivery estimates, and stock information:

ITAR Registered

Featured Parts

Explore our most requested parts, carefully selected based on customer demand and sourcing activity. Each listing provides current specifications, availability status, and item condition:

MS9068-246
5331-00-279-9118
O-Ring
MS9068-247
5330-01-408-1431
Preformed Packing
MS9068-248
5330-01-289-3415
Preformed Packing
MS9068-249
5331-00-223-1073
O-Ring
MS9068-250
5331-00-108-9989
O-Ring
MS9068-251
5331-00-849-6726
O-Ring
MS9068-252
5331-00-113-3805
O-Ring
MS9068-253
5331-00-949-5494
O-Ring
MS9068-254
5331-01-410-7097
O-Ring
MS9068-255
5331-00-989-6002
O-Ring
MS9068-257
5331-00-165-4507
O-Ring
MS9068-258
5331-00-530-0376
O-Ring
MS9068-259
5331-00-853-4272
O-Ring
MS9068-26
5331-00-814-2058
O-Ring
MS9068-260
5331-00-891-1760
O-Ring