1. Home /
  2. Catalog /
  3. Coils and Transformers /
  4. 5950-00-606-7413

5950-00-606-7413

Find complete technical information, availability, and procurement data for: 5950-00-606-7413

DODParts.com distributes related products varnishes dopes paints, aircraft parts and consumables, electrical parts, fittings and other components for the aerospace and defense industries. Submit the short price quote form for NSN 5950-00-606-7413 to receive an up to date pricing and availability quote by email.

5950-00-606-7413
Federal Supply Group
Electrical and Electronic Equipment Components
Federal Supply Classification
5950 Coils and Transformers
National Stock Number
5950-00-606-7413
Item Name Code
32496
Assigment Date
01/01/1963 (63 years ago)

An item consisting of electrical contacts mounted on an insulated plate which together form a section of a switch or relay. It includes both rotor and stator but does not include drive or actuating mechanism.

4.938 inches nominal overall height, 50.0 hertz nominal or 60.0 hertz nominal single component frequency rating, 3.312 inches nominal single mounting facility single center group center to center distance between mounting facilities parallel to length, 2.687 inches nominal single mounting facility single center group center to center distance between mounting facilities parallel to width, not established reliability indicator

Product Characteristics

Below you’ll find the complete technical specifications and performance data for this part, including material details and compliance information.

Reliability Indicator
not established
Center To Center Distance Between Mounting Facilities Parallel To Length
3.312 inches nominal single mounting facility single center group
Center To Center Distance Between Mounting Facilities Parallel To Width
2.687 inches nominal single mounting facility single center group
Overall Height
4.938 inches nominal
Frequency Rating
50.0 hertz nominal or 60.0 hertz nominal single component
Input-Output Phase Relationship
single phase to single phase single component
Winding Shielding Method
internal shield grounded to inclosure and core single component
Body Length
4.188 inches nominal
Body Width
3.563 inches nominal
Body Height
4.438 inches nominal
Inclosure Type
hermetically sealed
Mounting Facility Quantity
4 single group
Mounting Method
threaded stud single group
Winding Function And Quantity
2 primary and 3 secondary single component
Thread Quantity Per Inch
32 single group
Nominal Thread Size
0.190 inches single group
Winding Operating Current
1.5 amperes dc maximum single component 3rd secondary
Winding Operating Current
4.0 amperes dc maximum single component 1st secondary
Winding Operating Current
90.0 milliamperes dc maximum single component 2nd secondary
Winding Operating Voltage
115.00 ac volts nominal single component 1st primary
Winding Operating Voltage
230.00 ac volts nominal single component 2nd primary
Winding Operating Voltage
520.00 ac volts nominal single component 2nd secondary
Winding Operating Voltage
6.30 ac volts nominal single component 1st secondary
Winding Operating Voltage
6.30 ac volts nominal single component 3rd secondary
Thread Series Designator
unf single group
Terminal Type And Quantity
12 standoff, solder lug

Related Parts

This NSN group includes multiple components designed to meet specific performance and operational standards. Each listing provides detailed specs, functionality data, and replacement compatibility information:

Part Number Name
SMC174487 Power Transformer

FAQs

Find helpful answers about installation, operation, maintenance, compliance, and troubleshooting.

What is the FSCG of the NSN 5950-00-606-7413?
The FSCG of the NSN 5950-00-606-7413 is 5950
Does NSN 5950-00-606-7413 require demilitarization?
Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.
Does NSN 5950-00-606-7413 contain precious materials?
Precious metal content is unknown
Does NSN 5950-00-606-7413 contain hazardous materials?
Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
When the NSN 5950-00-606-7413 was assigned to the Federal Catalog?
It was assigned 63 years ago, on Tue, Jan 1, 1963

Professional Distribution

Certified to meet the strict requirements of defense, aerospace, and hazardous materials distribution.

  • ITAR Registered
  • DDTC Registered
  • HAZMAT Certified
  • AS9120 Quality Standards
  • 100% Quality Inspections

You May Also Like

Browse other in-demand NSN parts sourced by professionals in defense, aerospace, and manufacturing sectors. Each component meets strict standards for quality and performance.

Pricing

Submit your request below and our team will respond quickly with up-to-date pricing, delivery estimates, and stock information:

ITAR Registered

Featured Parts

Explore our most requested parts, carefully selected based on customer demand and sourcing activity. Each listing provides current specifications, availability status, and item condition:

10091741-101
5962-01-173-9978
Memory Microcircuit
10091741-102
5962-01-180-3450
Digital Microcircuit
10091741T1018
5962-01-180-3450
Digital Microcircuit
10091755
5330-01-692-6104
Gasket
1009178
3020-01-306-3135
Roller Chain
10091780
2940-01-357-9733
Fluid Filter
1009179
1650-00-525-2505
Directional Control Valve Piston
10091791-101
4920-01-190-8354
Test Adapter
10091794-101
4920-01-190-8353
Test Adapter
10091799-101
4920-01-189-0360
Test Adapter
100918
1680-00-773-3028
Piston Rod Assembly
100918-2
6110-01-272-4741
Motor Starter
100918-Z
5310-01-500-6552
Flat Washer
10091803-101
4920-01-194-9792
Test Adapter
10091808-101
4920-01-189-0359
Test Adapter