5950-00-456-0405

Find complete technical information, availability, and procurement data for: 5950-00-456-0405

DODParts.com distributes related products varnishes dopes paints, aircraft parts and consumables, electrical parts, fittings and other components for the aerospace and defense industries. Submit the short price quote form for NSN 5950-00-456-0405 to receive an up to date pricing and availability quote by email.

5950-00-456-0405
Federal Supply Group
Electrical and Electronic Equipment Components
Federal Supply Classification
5950 Coils and Transformers
National Stock Number
5950-00-456-0405
Item Name Code
32496
Assigment Date
04/25/1969 (57 years ago)

A transformer consisting of one or more primary winding(s) and one or more secondary winding(s). It may be designed for direct connection to an alternating current source for purposes of changing the secondary volts and amperes or designed to eliminate metallic interconnection between circuits in an overall one to one voltage ratio, with or without additional output windings, or items designed to automatically maintain a constant output voltage within specified limits under varying input or load conditions. Also includes items having a provision for mechanically changing the turns ratio or inductive coupling in progressive increments by means of voltage taps, ratio adjuster, or devices oe similar design. For transformers having winding(s) common to both input and output circuits, see transformer (1), power, autotransformer. Excludes:transformer (1), pulse.

3.580 inches nominal single mounting facility single center group center to center distance between mounting facilities parallel to length, delta-delta transformer winding connection type, 400.0 hertz nominal single component frequency rating, three phase to three phase single component input-output phase relationship, 1.430 inches nominal single mounting facility single center group center to center distance between mounting facilities parallel to width

Product Characteristics

Below you’ll find the complete technical specifications and performance data for this part, including material details and compliance information.

Center To Center Distance Between Mounting Facilities Parallel To Length
3.580 inches nominal single mounting facility single center group
Center To Center Distance Between Mounting Facilities Parallel To Width
1.430 inches nominal single mounting facility single center group
Frequency Rating
400.0 hertz nominal single component
Input-Output Phase Relationship
three phase to three phase single component
Transformer Winding Connection Type
delta-delta
Body Length
4.250 inches nominal
Body Width
2.650 inches nominal
Body Height
3.750 inches nominal
Inclosure Type
fully inclosed
Mounting Facility Quantity
4 single group
Mounting Method
threaded hole single group
Winding Function And Quantity
1 primary and 3 secondary single component
Thread Quantity Per Inch
32 single group
Nominal Thread Size
0.138 inches single group
Winding Operating Current
100.0 milliamperes ac maximum single component 1st secondary
Winding Operating Current
4.5 amperes ac maximum single component 2nd secondary
Winding Operating Current
4.5 amperes ac maximum single component 3rd secondary
Winding Operating Voltage
115.00 ac volts nominal single component single primary
Winding Operating Voltage
33.75 ac volts nominal single component 2nd secondary
Winding Operating Voltage
33.75 ac volts nominal single component 3rd secondary
Winding Operating Voltage
247.00 ac volts nominal single component 1st secondary
Thread Series Designator
unc single group
Terminal Type And Quantity
13 tab, solder lug

Replaces National Stock Numbers

Below is a list of NSNs that have been officially superseded by this NSN:

NSN Name Date
5950-00-097-8934 No Name Available 03/11/1972

Related Parts

This NSN group includes multiple components designed to meet specific performance and operational standards. Each listing provides detailed specs, functionality data, and replacement compatibility information:

Part Number Name
585958-1 Power Transformer
85958-1 Power Transformer

FAQs

Find helpful answers about installation, operation, maintenance, compliance, and troubleshooting.

What is the FSCG of the NSN 5950-00-456-0405?
The FSCG of the NSN 5950-00-456-0405 is 5950
Does NSN 5950-00-456-0405 require demilitarization?
Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.
Does NSN 5950-00-456-0405 contain precious materials?
Precious metal content is unknown
Does NSN 5950-00-456-0405 contain hazardous materials?
Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
When the NSN 5950-00-456-0405 was assigned to the Federal Catalog?
It was assigned 57 years ago, on Fri, Apr 25, 1969

Professional Distribution

Certified to meet the strict requirements of defense, aerospace, and hazardous materials distribution.

  • ITAR Registered
  • DDTC Registered
  • HAZMAT Certified
  • AS9120 Quality Standards
  • 100% Quality Inspections

You May Also Like

Browse other in-demand NSN parts sourced by professionals in defense, aerospace, and manufacturing sectors. Each component meets strict standards for quality and performance.

Pricing

Submit your request below and our team will respond quickly with up-to-date pricing, delivery estimates, and stock information:

ITAR Registered

Featured Parts

Explore our most requested parts, carefully selected based on customer demand and sourcing activity. Each listing provides current specifications, availability status, and item condition:

25332834
5935-01-653-7792
Electrical Plug Connector
25332840
5330-01-659-5730
Gasket
25332841
5935-01-555-6624
Electrical Connect End Seal Plug
25332863
5940-01-662-1727
Quick Disconnect Terminal
253329
6625-01-236-1427
Voltmeter
25332944
5945-01-663-2219
Electrical Relay Retainer
25332BUNAN
5331-00-579-7916
O-Ring
25333
1680-01-596-1946
Coupling Housing
25333-00939
5935-01-292-1554
Electrical Connector Backshell
2533301380
5340-01-442-7568
Vent Plug
253330RK
5930-00-945-7585
Rotary Switch Section
253337
5315-01-067-1777
Headless Straight Pin
25333812
2990-01-535-1271
Sensor,exhaust Gas,oxygen,emissi
253339-513
5930-00-139-1741
Rotary Switch
25333P-008
5307-00-145-4724
Stepped Stud