1. Home /
  2. Catalog /
  3. Coils and Transformers /
  4. 5950-00-213-6280

5950-00-213-6280

Find complete technical information, availability, and procurement data for: 5950-00-213-6280

DODParts.com distributes related products varnishes dopes paints, aircraft parts and consumables, electrical parts, fittings and other components for the aerospace and defense industries. Submit the short price quote form for NSN 5950-00-213-6280 to receive an up to date pricing and availability quote by email.

5950-00-213-6280
Federal Supply Group
Electrical and Electronic Equipment Components
Federal Supply Classification
5950 Coils and Transformers
National Stock Number
5950-00-213-6280
Item Name Code
32496
Assigment Date
04/25/1973 (53 years ago)

An electrical fitting with electrical contacts constructed to be affixed to the end of a cable, conduit, coaxial line, cord, wire (includes printed/etched), printed wiring board, or the like for convenience in joining with another electrical connector or printed wiring board. It is designed to be mounted on a bulkhead, chassis, panel, wall, printed wiring board, or the like. Excludes:lampholder; jack,telephone; jack,tip; insert electrical connector; insert module,electrical connector; connector body (as modified) and socket,plug-in electronic components. See also wiring harness (as modified) and cable assembly (as modified). For items with termination wires of more than four inches in length, see lead assembly,electrical. For items without inserts, see shell,electrical connector.

2.618 inches nominal single mounting facility single center group center to center distance between mounting facilities parallel to length, 1.0 kilohertz nominal single component frequency rating, 0.157 inches nominal single group mounting hole diameter, 1.889 inches nominal single mounting facility single center group center to center distance between mounting facilities parallel to width, not established reliability indicator

Product Characteristics

Below you’ll find the complete technical specifications and performance data for this part, including material details and compliance information.

Reliability Indicator
not established
Center To Center Distance Between Mounting Facilities Parallel To Length
2.618 inches nominal single mounting facility single center group
Center To Center Distance Between Mounting Facilities Parallel To Width
1.889 inches nominal single mounting facility single center group
Mounting Hole Diameter
0.157 inches nominal single group
Frequency Rating
1.0 kilohertz nominal single component
Input-Output Phase Relationship
single phase to single phase single component
Body Length
3.031 inches nominal
Body Width
2.480 inches nominal
Body Height
3.228 inches nominal
Inclosure Type
open
Mounting Facility Quantity
4 single group
Mounting Method
flange and unthreaded hole single group
Winding Function And Quantity
1 primary and 2 secondary single component
Winding Operating Voltage
21.00 ac volts nominal single component 1st secondary
Winding Operating Voltage
23.00 ac volts nominal single component 2nd secondary
Winding Operating Voltage
95.00 ac volts nominal and 100.00 ac volts nominal single component single primary
Terminal Type And Quantity
7 tab, solder lug

Related Parts

This NSN group includes multiple components designed to meet specific performance and operational standards. Each listing provides detailed specs, functionality data, and replacement compatibility information:

Part Number Name
209022800 Power Transformer

FAQs

Find helpful answers about installation, operation, maintenance, compliance, and troubleshooting.

What is the FSCG of the NSN 5950-00-213-6280?
The FSCG of the NSN 5950-00-213-6280 is 5950
Does NSN 5950-00-213-6280 require demilitarization?
Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.
Does NSN 5950-00-213-6280 contain precious materials?
Precious metal content is unknown
Does NSN 5950-00-213-6280 contain hazardous materials?
Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
When the NSN 5950-00-213-6280 was assigned to the Federal Catalog?
It was assigned 53 years ago, on Wed, Apr 25, 1973

Professional Distribution

Certified to meet the strict requirements of defense, aerospace, and hazardous materials distribution.

  • ITAR Registered
  • DDTC Registered
  • HAZMAT Certified
  • AS9120 Quality Standards
  • 100% Quality Inspections

You May Also Like

Browse other in-demand NSN parts sourced by professionals in defense, aerospace, and manufacturing sectors. Each component meets strict standards for quality and performance.

Pricing

Submit your request below and our team will respond quickly with up-to-date pricing, delivery estimates, and stock information:

ITAR Registered

Featured Parts

Explore our most requested parts, carefully selected based on customer demand and sourcing activity. Each listing provides current specifications, availability status, and item condition:

UCC27712
5962-01-693-3899
Linear Microcircuit
UCC27712D
5962-01-693-3899
Linear Microcircuit
UCC2800D
5962-01-564-3756
Digital Microcircuit
UCC2804D
5962-01-660-7782
Digital Microcircuit
UCC2804N
5962-01-502-9897
Linear Microcircuit
UCC2804PW
5962-01-673-7794
Digital Microcircuit
UCC2806DW
5962-01-458-0799
Digital Microcircuit
UCC2806DWTR (ROHS)
5962-01-566-7059
Digital Microcircuit
UCC28220DR
5962-01-686-7140
Linear Microcircuit
UCC283T-3
5962-01-679-4297
Linear Microcircuit
UCC284DP-5
5962-01-625-4843
Linear Microcircuit
UCC284DP-ADJ
5962-01-605-3815
Linear Microcircuit
UCC284SDR-5EP
5962-01-647-8552
Linear Microcircuit
UCC2891
5962-01-651-9683
Digital Microcircuit
UCC2895DW
5962-01-673-7797
Digital Microcircuit