DODParts.com distributes related products varnishes dopes paints, aircraft parts and consumables, electrical parts, fittings and other components for the aerospace and defense industries. Submit the short price quote form for NSN 5950-00-136-7040 to receive an up to date pricing and availability quote by email.
A transformer consisting of one or more primary winding(s) and one or more secondary winding(s). It may be designed for direct connection to an alternating current source for purposes of changing the secondary volts and amperes or designed to eliminate metallic interconnection between circuits in an overall one to one voltage ratio, with or without additional output windings, or items designed to automatically maintain a constant output voltage within specified limits under varying input or load conditions. Also includes items having a provision for mechanically changing the turns ratio or inductive coupling in progressive increments by means of voltage taps, ratio adjuster, or devices oe similar design. For transformers having winding(s) common to both input and output circuits, see transformer (1), power, autotransformer. Excludes:transformer (1), pulse.
3.150 inches maximum overall length, not established reliability indicator, 1.125 inches nominal 1st mounting facility single center group center to center distance between mounting facilities parallel to width, 2.000 inches nominal single mounting facility single center group center to center distance between mounting facilities parallel to length, 1.125 inches nominal 2nd mounting facility single center group center to center distance between mounting facilities parallel to width
Product Characteristics
Below you’ll find the complete technical specifications and performance data for this part, including material details and compliance information.
- Reliability Indicator
- not established
- Overall Length
- 3.150 inches maximum
- Center To Center Distance Between Mounting Facilities Parallel To Length
- 2.000 inches nominal single mounting facility single center group
- Center To Center Distance Between Mounting Facilities Parallel To Width
- 1.125 inches nominal 2nd mounting facility single center group
- Center To Center Distance Between Mounting Facilities Parallel To Width
- 1.125 inches nominal 1st mounting facility single center group
- Frequency Rating
- 380.0 hertz minimum and 420.0 hertz maximum single component
- Input-Output Phase Relationship
- single phase to single phase single component
- Body Width
- 2.250 inches maximum
- Body Height
- 2.870 inches nominal
- Maximum Operating Temp
- 130.0 celsius
- Inclosure Type
- open
- Mounting Facility Quantity
- 2 2nd group
- Mounting Facility Quantity
- 4 1st group
- Mounting Method
- threaded hole all groupings
- Winding Function And Quantity
- 1 primary and 7 secondary single component
- Features Provided
- color coded lead
- Nominal Thread Size
- 0.112 inches 2nd group
- Nominal Thread Size
- 0.138 inches 1st group
- Winding Operating Current
- 233.0 microamperes ac nominal single component 1st secondary
- Winding Operating Current
- 111.2 milliamperes ac nominal single component 3rd secondary
- Winding Operating Current
- 58.2 milliamperes ac nominal single component 4th secondary
- Winding Operating Current
- 33.5 milliamperes ac nominal single component 2nd secondary
- Winding Operating Voltage
- 115.00 ac volts nominal single component single primary
- Winding Operating Voltage
- 344.50 ac volts nominal single component 3rd secondary
- Winding Operating Voltage
- 248.00 ac volts nominal single component 4th secondary
- Winding Operating Voltage
- 2578.00 ac volts nominal single component 1st secondary
- Winding Operating Voltage
- 79.60 ac volts nominal single component 2nd secondary
- Special Features
- 1 primary winding; 7 secondary windings
- Thread Series Designator
- unc all groupings
- Terminal Type And Quantity
- 16 wire lead
Related Parts
This NSN group includes multiple components designed to meet specific performance and operational standards. Each listing provides detailed specs, functionality data, and replacement compatibility information:
| Part Number | Name |
|---|---|
| 307935-1 | Power Transformer |
FAQs
Find helpful answers about installation, operation, maintenance, compliance, and troubleshooting.
What is the FSCG of the NSN 5950-00-136-7040?
Does NSN 5950-00-136-7040 require demilitarization?
Does NSN 5950-00-136-7040 contain precious materials?
Does NSN 5950-00-136-7040 contain hazardous materials?
When the NSN 5950-00-136-7040 was assigned to the Federal Catalog?
Professional Distribution
Certified to meet the strict requirements of defense, aerospace, and hazardous materials distribution.
- ITAR Registered
- DDTC Registered
- HAZMAT Certified
- AS9120 Quality Standards
- 100% Quality Inspections
You May Also Like
Browse other in-demand NSN parts sourced by professionals in defense, aerospace, and manufacturing sectors. Each component meets strict standards for quality and performance.
Pricing
Submit your request below and our team will respond quickly with up-to-date pricing, delivery estimates, and stock information: