1. Home /
  2. Catalog /
  3. Coils and Transformers /
  4. 5950-00-125-5525

5950-00-125-5525

Find complete technical information, availability, and procurement data for: 5950-00-125-5525

DODParts.com distributes related products varnishes dopes paints, aircraft parts and consumables, electrical parts, fittings and other components for the aerospace and defense industries. Submit the short price quote form for NSN 5950-00-125-5525 to receive an up to date pricing and availability quote by email.

5950-00-125-5525
Federal Supply Group
Electrical and Electronic Equipment Components
Federal Supply Classification
5950 Coils and Transformers
National Stock Number
5950-00-125-5525
Item Name Code
32496
Assigment Date
11/20/1968 (57 years ago)

A transformer consisting of one or more primary winding(s) and one or more secondary winding(s). It may be designed for direct connection to an alternating current source for purposes of changing the secondary volts and amperes or designed to eliminate metallic interconnection between circuits in an overall one to one voltage ratio, with or without additional output windings, or items designed to automatically maintain a constant output voltage within specified limits under varying input or load conditions. Also includes items having a provision for mechanically changing the turns ratio or inductive coupling in progressive increments by means of voltage taps, ratio adjuster, or devices oe similar design. For transformers having winding(s) common to both input and output circuits, see transformer (1), power, autotransformer. Excludes:transformer (1), pulse.

single phase to single phase single component input-output phase relationship, 400.0 hertz nominal single component frequency rating, not established reliability indicator, 2.125 inches nominal single mounting facility single center group center to center distance between mounting facilities parallel to width, 2.625 inches nominal single mounting facility single center group center to center distance between mounting facilities parallel to length

Product Characteristics

Below you’ll find the complete technical specifications and performance data for this part, including material details and compliance information.

Reliability Indicator
not established
Center To Center Distance Between Mounting Facilities Parallel To Length
2.625 inches nominal single mounting facility single center group
Center To Center Distance Between Mounting Facilities Parallel To Width
2.125 inches nominal single mounting facility single center group
Frequency Rating
400.0 hertz nominal single component
Input-Output Phase Relationship
single phase to single phase single component
Body Length
3.560 inches nominal
Body Width
3.060 inches nominal
Body Height
3.880 inches nominal
Inclosure Type
fully inclosed
Mounting Facility Quantity
4 single group
Mounting Method
threaded stud single group
Winding Function And Quantity
1 primary and 1 secondary single component
Thread Quantity Per Inch
32 single group
Nominal Thread Size
0.164 inches single group
Winding Operating Current
25.0 milliamperes ac maximum single component single secondary
Winding Operating Voltage
115.00 ac volts nominal single component single primary
Winding Operating Voltage
3.605 ac kilovolts nominal single component single secondary
Thread Series Designator
unc single group
Terminal Type And Quantity
4 tab, solder lug

FAQs

Find helpful answers about installation, operation, maintenance, compliance, and troubleshooting.

What is the FSCG of the NSN 5950-00-125-5525?
The FSCG of the NSN 5950-00-125-5525 is 5950
Does NSN 5950-00-125-5525 require demilitarization?
Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.
Does NSN 5950-00-125-5525 contain precious materials?
Precious metal content is unknown
Does NSN 5950-00-125-5525 contain hazardous materials?
Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
When the NSN 5950-00-125-5525 was assigned to the Federal Catalog?
It was assigned 57 years ago, on Wed, Nov 20, 1968

Professional Distribution

Certified to meet the strict requirements of defense, aerospace, and hazardous materials distribution.

  • ITAR Registered
  • DDTC Registered
  • HAZMAT Certified
  • AS9120 Quality Standards
  • 100% Quality Inspections

You May Also Like

Browse other in-demand NSN parts sourced by professionals in defense, aerospace, and manufacturing sectors. Each component meets strict standards for quality and performance.

Pricing

Submit your request below and our team will respond quickly with up-to-date pricing, delivery estimates, and stock information:

ITAR Registered

Featured Parts

Explore our most requested parts, carefully selected based on customer demand and sourcing activity. Each listing provides current specifications, availability status, and item condition:

131-1253
5310-01-183-8752
Hexagon Self-Locking Nut
131-1254-01
5999-01-015-1129
Electrical Contact
131-126
5935-00-911-9353
Electrical Receptacle Connector
131-1261-00
5999-01-045-3131
Electrical Contact
131-1266-00
5999-00-139-0347
Electrical Contact
131-1270-00
6150-01-285-8630
Conductor Bus
131-129
4520-01-430-2617
Space Heater
131-129-1
5910-00-811-2364
Ceramic Dielectr Fixed Capacitor
131-129GE
5999-00-450-9708
Electrical Contact
131-12A-113
2990-01-674-5199
Horizontal Silencer
131-12B-111
2990-01-674-4725
Vertical Silencer
131-13-02-024
5935-00-476-1356
Plug-in Electronic Compon Socket
131-1302-00
5999-01-082-1878
Electrical Contact
131-1303-00
5999-01-192-1409
Electrical-Electronic Heat Sink
131-130P31
5910-00-112-7161
Paper Dielectric Fixed Capacitor