1. Home /
  2. Catalog /
  3. Coils and Transformers /
  4. 5950-00-071-7718

5950-00-071-7718

Find complete technical information, availability, and procurement data for: 5950-00-071-7718

DODParts.com distributes related products varnishes dopes paints, aircraft parts and consumables, electrical parts, fittings and other components for the aerospace and defense industries. Submit the short price quote form for NSN 5950-00-071-7718 to receive an up to date pricing and availability quote by email.

5950-00-071-7718
Federal Supply Group
Electrical and Electronic Equipment Components
Federal Supply Classification
5950 Coils and Transformers
National Stock Number
5950-00-071-7718
Item Name Code
32496
Assigment Date
07/18/1967 (59 years ago)

A transformer consisting of one or more primary winding(s) and one or more secondary winding(s). It may be designed for direct connection to an alternating current source for purposes of changing the secondary volts and amperes or designed to eliminate metallic interconnection between circuits in an overall one to one voltage ratio, with or without additional output windings, or items designed to automatically maintain a constant output voltage within specified limits under varying input or load conditions. Also includes items having a provision for mechanically changing the turns ratio or inductive coupling in progressive increments by means of voltage taps, ratio adjuster, or devices oe similar design. For transformers having winding(s) common to both input and output circuits, see transformer (1), power, autotransformer. Excludes:transformer (1), pulse.

55.0 hertz minimum and 65.0 hertz maximum single component frequency rating, 4.063 inches nominal single mounting facility single center group center to center distance between mounting facilities parallel to length, single phase to single phase single component input-output phase relationship, 3.313 inches nominal single mounting facility single center group center to center distance between mounting facilities parallel to width, not established reliability indicator

Product Characteristics

Below you’ll find the complete technical specifications and performance data for this part, including material details and compliance information.

Reliability Indicator
not established
Center To Center Distance Between Mounting Facilities Parallel To Length
4.063 inches nominal single mounting facility single center group
Center To Center Distance Between Mounting Facilities Parallel To Width
3.313 inches nominal single mounting facility single center group
Frequency Rating
55.0 hertz minimum and 65.0 hertz maximum single component
Input-Output Phase Relationship
single phase to single phase single component
Winding Shielding Method
internal shield grounded to core single component
Body Length
5.063 inches nominal
Body Width
4.313 inches nominal
Body Height
5.500 inches nominal
Inclosure Type
hermetically sealed
Mounting Facility Quantity
4 single group
Mounting Method
threaded hole single group
Winding Function And Quantity
1 primary and 2 secondary single component
Thread Quantity Per Inch
20 single group
Nominal Thread Size
0.250 inches single group
Winding Operating Current
250.0 milliamperes dc maximum single component 2nd secondary
Winding Operating Current
8.0 amperes dc maximum single component 1st secondary
Winding Operating Voltage
108.00 ac volts nominal and 120.00 ac volts nominal and 132.00 ac volts nominal single component single primary
Winding Operating Voltage
15.00 ac volts nominal single component 2nd secondary
Winding Operating Voltage
22.00 ac volts nominal single component 1st secondary
Thread Series Designator
unc single group
Terminal Type And Quantity
8 tab, solder lug

Replaces National Stock Numbers

Below is a list of NSNs that have been officially superseded by this NSN:

NSN Name Date
5950-00-757-3248 No Name Available 07/01/1976

Related Parts

This NSN group includes multiple components designed to meet specific performance and operational standards. Each listing provides detailed specs, functionality data, and replacement compatibility information:

Part Number Name
48169 Power Transformer
AE7981 Power Transformer
T3666 Power Transformer

FAQs

Find helpful answers about installation, operation, maintenance, compliance, and troubleshooting.

What is the FSCG of the NSN 5950-00-071-7718?
The FSCG of the NSN 5950-00-071-7718 is 5950
Does NSN 5950-00-071-7718 require demilitarization?
Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.
Does NSN 5950-00-071-7718 contain precious materials?
Precious metal content is unknown
Does NSN 5950-00-071-7718 contain hazardous materials?
Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
When the NSN 5950-00-071-7718 was assigned to the Federal Catalog?
It was assigned 59 years ago, on Tue, Jul 18, 1967

Professional Distribution

Certified to meet the strict requirements of defense, aerospace, and hazardous materials distribution.

  • ITAR Registered
  • DDTC Registered
  • HAZMAT Certified
  • AS9120 Quality Standards
  • 100% Quality Inspections

You May Also Like

Browse other in-demand NSN parts sourced by professionals in defense, aerospace, and manufacturing sectors. Each component meets strict standards for quality and performance.

Pricing

Submit your request below and our team will respond quickly with up-to-date pricing, delivery estimates, and stock information:

ITAR Registered

Featured Parts

Explore our most requested parts, carefully selected based on customer demand and sourcing activity. Each listing provides current specifications, availability status, and item condition:

435-022-260
5305-01-422-4347
Setscrew
435-022-354
5305-01-422-4355
Setscrew
435-023-359
5305-01-422-6610
Setscrew
435-03-0001-1
1290-00-669-9062
Electrical Synchronizer
435-03-3011
5950-00-090-0226
Power Transformer
435-03-3034
1270-00-211-7136
Control Panel Post
435-03-3045
1270-00-211-7051
Latch
435-03-3046
1270-00-211-7014
Latch Guide
435-03-3056
1270-00-321-5138
Hinge Termina Cover
435-03-3084
1270-00-211-6912
Synchronizer Cover
435-03-3086
5340-00-211-6913
Access Cover
435-03-3101
5895-00-318-1488
Electrical Synchronizer Subassem
435-03-3102
5895-00-318-1489
Electrical Synchronizer Subassem
435-03-3103
5895-00-318-1490
Electrical Synchronizer Subassem
435-03-3104
5895-00-318-1491
Electrical Synchronizer Subassem