C8840

View detailed technical data, stock status, and sourcing information for: C8840

DODParts.com distributes related products varnishes dopes paints, aircraft parts and consumables, electrical parts, fittings and other components for the aerospace and defense industries. Submit the short price quote form for part C8840 to receive an up to date pricing and availability quote by email.

C8840
Federal Supply Group
Electrical and Electronic Equipment Components
Federal Supply Classification
5950 Coils and Transformers
National Stock Number
5950-00-059-3010
Item Name Code
32496
Assigment Date
01/01/1961 (65 years ago)

A transformer consisting of one or more primary winding(s) and one or more secondary winding(s). It may be designed for direct connection to an alternating current source for purposes of changing the secondary volts and amperes or designed to eliminate metallic interconnection between circuits in an overall one to one voltage ratio, with or without additional output windings, or items designed to automatically maintain a constant output voltage within specified limits under varying input or load conditions. Also includes items having a provision for mechanically changing the turns ratio or inductive coupling in progressive increments by means of voltage taps, ratio adjuster, or devices oe similar design. For transformers having winding(s) common to both input and output circuits, see transformer (1), power, autotransformer. Excludes:transformer (1), pulse.

3.937 inches minimum and 4.249 inches maximum overall height, 60.0 hertz nominal single component frequency rating, 2.125 inches nominal single mounting facility single center group center to center distance between mounting facilities parallel to length, not established reliability indicator, 1.750 inches nominal single mounting facility single center group center to center distance between mounting facilities parallel to width

Product Characteristics

Below you’ll find the complete technical specifications and performance data for this part, including material details and compliance information.

Reliability Indicator
not established
Center To Center Distance Between Mounting Facilities Parallel To Length
2.125 inches nominal single mounting facility single center group
Center To Center Distance Between Mounting Facilities Parallel To Width
1.750 inches nominal single mounting facility single center group
Overall Height
3.937 inches minimum and 4.249 inches maximum
Frequency Rating
60.0 hertz nominal single component
Input-Output Phase Relationship
single phase to single phase single component
Winding Shielding Method
internal shield grounded to inclosure single component
Body Length
2.625 inches minimum and 2.750 inches maximum
Body Width
2.250 inches minimum and 2.375 inches maximum
Body Height
3.624 inches minimum and 3.812 inches maximum
Maximum Operating Temp
105.0 celsius
Inclosure Type
hermetically sealed
Mounting Facility Quantity
4 single group
Mounting Method
threaded stud single group
Winding Function And Quantity
1 primary and 2 secondary single component
Thread Quantity Per Inch
32 single group
Nominal Thread Size
0.164 inches single group
Winding Operating Current
500.0 milliamperes ac maximum single component 1st secondary
Winding Operating Current
400.0 milliamperes ac maximum single component 2nd secondary
Winding Operating Voltage
18.00 ac volts nominal single component 1st secondary
Winding Operating Voltage
64.00 ac volts nominal and 143.00 ac volts nominal single component 2nd secondary
Winding Operating Voltage
65.00 ac volts nominal single component single primary
Thread Series Designator
unc single group
Terminal Type And Quantity
8 solder stud

Related Parts

This NSN group includes multiple components designed to meet specific performance and operational standards. Each listing provides detailed specs, functionality data, and replacement compatibility information:

Part Number Name
C8840 Power Transformer

FAQs

Find helpful answers about installation, operation, maintenance, compliance, and troubleshooting.

What is the FSCG of the NSN 5950-00-059-3010?
The FSCG of the NSN 5950-00-059-3010 is 5950
Does NSN 5950-00-059-3010 require demilitarization?
Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.
Does NSN 5950-00-059-3010 contain precious materials?
Precious metal content is unknown
Does NSN 5950-00-059-3010 contain hazardous materials?
Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
When the NSN 5950-00-059-3010 was assigned to the Federal Catalog?
It was assigned 65 years ago, on Sun, Jan 1, 1961

Professional Distribution

Certified to meet the strict requirements of defense, aerospace, and hazardous materials distribution.

  • ITAR Registered
  • DDTC Registered
  • HAZMAT Certified
  • AS9120 Quality Standards
  • 100% Quality Inspections

You May Also Like

Browse other in-demand NSN parts sourced by professionals in defense, aerospace, and manufacturing sectors. Each component meets strict standards for quality and performance.

Pricing

Submit your request below and our team will respond quickly with up-to-date pricing, delivery estimates, and stock information:

ITAR Registered

Featured Parts

Explore our most requested parts, carefully selected based on customer demand and sourcing activity. Each listing provides current specifications, availability status, and item condition:

006873
5999-00-583-2151
Electrical Contact
00687310
5340-01-096-1495
Retaining Strap
006874
5905-00-112-4589
Resistor,variable,wire Wound,non
006875
5999-00-583-2153
Electrical Contact
006876
5950-00-306-3424
Power Transformer
006877
3010-01-669-0616
Flexible Shaft Coupling
00687752001501
4320-01-448-6266
Rotor and Shaft Pump Assembly
00687752002379
5910-01-448-9404
Glass Dielectric Fixed Capacitor
00687752002393
5330-01-447-8655
Gasket Set
00687752003345
5330-01-448-9741
Gasket
00687752005424
3010-00-102-6581
Flexible Shaft Coupling
00687752005462
5330-00-195-3634
Gasket Set
00687752005486
6105-01-303-4259
Alternating Current Motor
00687752005493
4320-00-018-2725
Impeller and Shaft
00687752005509
6105-00-213-7414
Alternating Current Motor