292-11109G1

View detailed technical data, stock status, and sourcing information for: 292-11109G1

DODParts.com distributes related products varnishes dopes paints, aircraft parts and consumables, electrical parts, fittings and other components for the aerospace and defense industries. Submit the short price quote form for part 292-11109G1 to receive an up to date pricing and availability quote by email.

292-11109G1
Federal Supply Group
Electrical and Electronic Equipment Components
Federal Supply Classification
5950 Coils and Transformers
National Stock Number
5950-00-019-3119
Item Name Code
32496
Assigment Date
01/01/1961 (65 years ago)

A transformer consisting of one or more primary winding(s) and one or more secondary winding(s). It may be designed for direct connection to an alternating current source for purposes of changing the secondary volts and amperes or designed to eliminate metallic interconnection between circuits in an overall one to one voltage ratio, with or without additional output windings, or items designed to automatically maintain a constant output voltage within specified limits under varying input or load conditions. Also includes items having a provision for mechanically changing the turns ratio or inductive coupling in progressive increments by means of voltage taps, ratio adjuster, or devices oe similar design. For transformers having winding(s) common to both input and output circuits, see transformer (1), power, autotransformer. Excludes:transformer (1), pulse.

400.0 hertz nominal single component frequency rating, 3.375 inches nominal single mounting facility single center group center to center distance between mounting facilities parallel to width, not established reliability indicator, 5.500 inches nominal single mounting facility single center group center to center distance between mounting facilities parallel to length, 0.375 inches nominal single group mounting hole diameter

Product Characteristics

Below you’ll find the complete technical specifications and performance data for this part, including material details and compliance information.

Reliability Indicator
not established
Center To Center Distance Between Mounting Facilities Parallel To Length
5.500 inches nominal single mounting facility single center group
Center To Center Distance Between Mounting Facilities Parallel To Width
3.375 inches nominal single mounting facility single center group
Mounting Hole Diameter
0.375 inches nominal single group
Frequency Rating
400.0 hertz nominal single component
Input-Output Phase Relationship
three phase to three phase single component
Body Length
7.625 inches nominal
Body Width
4.500 inches nominal
Body Height
7.875 inches nominal
Inclosure Type
fully inclosed
Mounting Facility Quantity
4 single group
Mounting Method
flange and unthreaded hole single group
Winding Function And Quantity
1 primary and 1 secondary single component
Winding Operating Voltage
115.00 ac volts nominal single component single primary
Terminal Type And Quantity
7 threaded stud

Related Parts

This NSN group includes multiple components designed to meet specific performance and operational standards. Each listing provides detailed specs, functionality data, and replacement compatibility information:

Part Number Name
292-11109G1 Power Transformer

FAQs

Find helpful answers about installation, operation, maintenance, compliance, and troubleshooting.

What is the FSCG of the NSN 5950-00-019-3119?
The FSCG of the NSN 5950-00-019-3119 is 5950
Does NSN 5950-00-019-3119 require demilitarization?
Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.
Does NSN 5950-00-019-3119 contain precious materials?
Precious metal content is unknown
Does NSN 5950-00-019-3119 contain hazardous materials?
Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
When the NSN 5950-00-019-3119 was assigned to the Federal Catalog?
It was assigned 65 years ago, on Sun, Jan 1, 1961

Professional Distribution

Certified to meet the strict requirements of defense, aerospace, and hazardous materials distribution.

  • ITAR Registered
  • DDTC Registered
  • HAZMAT Certified
  • AS9120 Quality Standards
  • 100% Quality Inspections

You May Also Like

Browse other in-demand NSN parts sourced by professionals in defense, aerospace, and manufacturing sectors. Each component meets strict standards for quality and performance.

Pricing

Submit your request below and our team will respond quickly with up-to-date pricing, delivery estimates, and stock information:

ITAR Registered

Featured Parts

Explore our most requested parts, carefully selected based on customer demand and sourcing activity. Each listing provides current specifications, availability status, and item condition:

802027365900-1
5985-01-607-6878
Release Pin A00 Nrp
802027365901-1
5985-01-607-6881
Quick Release P Nrp
802027365902-1
5985-01-607-6877
Quick Release P Nrp
802027366801-1
5995-01-566-2216
Radio Frequency Cable Assembly
802027366805-1
5985-01-607-6484
Lt A009 Adapter Nrp
802027366806-1
5985-01-607-6488
Hi Band Ant Ada Nrp
802027366807-1
5985-01-607-6492
Hi Band Ant Ada Nrp
802027366808-2
5995-01-566-2213
Radio Frequency Cable Assembly
802027366809-1
5985-01-607-6498
Maury Mismatch Nrp
802027366810-1
5985-01-607-6503
Adapter A014 Nrp
802027366821-2
6140-01-566-2217
Storage Battery
802027366821-4
6150-01-527-1964
E Special Purpose Cable Assembly
802027366828-1
5985-01-607-6506
Adapter A016 Nrp
802027366835-1
5935-01-651-4316
Electrical Connector Cover
802027366890-1
5120-01-659-2358
Torque Screwdriver