1. Home /
  2. Catalog /
  3. Coils and Transformers /
  4. 5950-00-003-0924

5950-00-003-0924

Find complete technical information, availability, and procurement data for: 5950-00-003-0924

DODParts.com distributes related products varnishes dopes paints, aircraft parts and consumables, electrical parts, fittings and other components for the aerospace and defense industries. Submit the short price quote form for NSN 5950-00-003-0924 to receive an up to date pricing and availability quote by email.

5950-00-003-0924
Federal Supply Group
Electrical and Electronic Equipment Components
Federal Supply Classification
5950 Coils and Transformers
National Stock Number
5950-00-003-0924
Item Name Code
32496
Assigment Date
05/11/1972 (54 years ago)

A transformer consisting of one or more primary winding(s) and one or more secondary winding(s). It may be designed for direct connection to an alternating current source for purposes of changing the secondary volts and amperes or designed to eliminate metallic interconnection between circuits in an overall one to one voltage ratio, with or without additional output windings, or items designed to automatically maintain a constant output voltage within specified limits under varying input or load conditions. Also includes items having a provision for mechanically changing the turns ratio or inductive coupling in progressive increments by means of voltage taps, ratio adjuster, or devices oe similar design. For transformers having winding(s) common to both input and output circuits, see transformer (1), power, autotransformer. Excludes:transformer (1), pulse.

internal shield brought out to terminal single component winding shielding method, not established reliability indicator, 4.250 inches nominal single mounting facility single center group center to center distance between mounting facilities parallel to width, single phase to single phase single component input-output phase relationship, 5.156 inches nominal single mounting facility single center group center to center distance between mounting facilities parallel to length

Product Characteristics

Below you’ll find the complete technical specifications and performance data for this part, including material details and compliance information.

Reliability Indicator
not established
Center To Center Distance Between Mounting Facilities Parallel To Length
5.156 inches nominal single mounting facility single center group
Center To Center Distance Between Mounting Facilities Parallel To Width
4.250 inches nominal single mounting facility single center group
Input-Output Phase Relationship
single phase to single phase single component
Winding Shielding Method
internal shield brought out to terminal single component
Body Length
7.438 inches nominal
Body Width
5.375 inches nominal
Body Height
8.025 inches nominal
Inclosure Type
fully inclosed
Mounting Facility Quantity
4 single group
Mounting Method
threaded stud single group
Winding Function And Quantity
1 primary and 1 secondary single component
Nominal Thread Size
0.250 inches single group
Thread Series Designator
unc single group
Terminal Type And Quantity
7 tab, solder lug

Related Parts

This NSN group includes multiple components designed to meet specific performance and operational standards. Each listing provides detailed specs, functionality data, and replacement compatibility information:

Part Number Name
126-2832 Power Transformer

FAQs

Find helpful answers about installation, operation, maintenance, compliance, and troubleshooting.

What is the FSCG of the NSN 5950-00-003-0924?
The FSCG of the NSN 5950-00-003-0924 is 5950
Does NSN 5950-00-003-0924 require demilitarization?
Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.
Does NSN 5950-00-003-0924 contain precious materials?
Precious metal content is unknown
Does NSN 5950-00-003-0924 contain hazardous materials?
Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
When the NSN 5950-00-003-0924 was assigned to the Federal Catalog?
It was assigned 54 years ago, on Thu, May 11, 1972

Professional Distribution

Certified to meet the strict requirements of defense, aerospace, and hazardous materials distribution.

  • ITAR Registered
  • DDTC Registered
  • HAZMAT Certified
  • AS9120 Quality Standards
  • 100% Quality Inspections

You May Also Like

Browse other in-demand NSN parts sourced by professionals in defense, aerospace, and manufacturing sectors. Each component meets strict standards for quality and performance.

Pricing

Submit your request below and our team will respond quickly with up-to-date pricing, delivery estimates, and stock information:

ITAR Registered

Featured Parts

Explore our most requested parts, carefully selected based on customer demand and sourcing activity. Each listing provides current specifications, availability status, and item condition:

1115861
2920-01-070-6681
El Engine Starter Relay-Solenoid
1115866
6350-00-489-9399
Buzzer
1115872
5310-01-368-7403
Hexagon Plain Nut
111588
1630-00-483-7650
Cylinder Hydraulic Stop
111588-0001
6145-01-663-1386
Radio Frequency Cable
1115881
5945-01-192-0581
Relay
1115882
5340-01-573-4981
Roller Holder
111588201
5340-01-573-4981
Roller Holder
111588202
5340-01-573-6586
Roller Holder
1115886
5315-01-595-1370
Machine Key
111589
1630-00-474-1056
Retainer
111589-1
5310-00-852-7918
Recessed Washer
1115892
2920-00-197-1692
Engine Generator Cutout Relay
111589201
5365-01-573-5733
Shim
111589401
2590-01-573-5269
Vehicular Components Bracket