Find complete technical information, availability, and procurement data for: 5925-01-519-1313

DODParts.com distributes related products varnishes dopes paints, aircraft parts and consumables, electrical parts, fittings and other components for the aerospace and defense industries. Submit the short price quote form for NSN 5925-01-519-1313 to receive an up to date pricing and availability quote by email.

5925-01-519-1313
Federal Supply Group
Electrical and Electronic Equipment Components
Federal Supply Classification
5925 Circuit Breakers
National Stock Number
5925-01-519-1313
Item Name Code
00136
Assigment Date
04/07/2004 (22 years ago)

0.624 inches nominal body width, single pole type body style, 0.694 inches minimum and 0.714 inches maximum center to center distance between terminals parallel to length, 0.250 inches nominal bushing length, 0.750 inches nominal body length

Product Characteristics

Below you’ll find the complete technical specifications and performance data for this part, including material details and compliance information.

Body Style
single pole type
Bushing Length
0.250 inches nominal
Body Length
0.750 inches nominal
Body Width
0.624 inches nominal
Center To Center Distance Between Terminals Parallel To Length
0.694 inches minimum and 0.714 inches maximum
End Item Identification
kc-46a tanker
Mounting Surface To Terminal End Distance
1.302 inches minimum and 1.322 inches maximum
Pole Quantity
1
Mounting Facility Type And Quantity
1 threaded bushing
Thread Quantity Per Inch
32
Maximum Continuous Load Current Rating Per Pole
2.500 amperes ac and 2.500 amperes dc single location
Operating Voltage Type And Rating Per Pole In Volts
120.0 ac and 30.0 dc single location
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
2800.0 ac and 3400.0 dc single location
Circuit Protection Type
overcurrent single location
Trip Release Method
thermal single location
Trip Release Characteristic
time delay single location
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
138.0 single location
Reset Method
manual
Main Contact Tripping Mechanism Type
trip free
Manual Actuator Type And Quantity
1 push-pull
Nominal Thread Size
0.4688 inches
Trip Delay Time In Seconds Per Rated Continuous Current
4.000 minimum at 200 pct and 20.000 maximum at 200 pct and 0.400 minimum at 500 pct and 2.000 maximum at 500 pct and 0.100 minimum at 1000 pct and 0.530 maximum at 1000 pct single location
Trip Release Ambient Temp Rating
25.0 celsius nominal single location
Unpackaged Unit Weight
30.000 grams nominal
Special Features
item is faa certified
Frequency In Hertz
400.0 single location
Thread Series Designator
uns
Terminal Type And Quantity
2 tab w/screw

Related Parts

This NSN group includes multiple components designed to meet specific performance and operational standards. Each listing provides detailed specs, functionality data, and replacement compatibility information:

Part Number Name
2TC47-21/2 Circuit Breaker
BACC18AD2 Circuit Breaker

FAQs

Find helpful answers about installation, operation, maintenance, compliance, and troubleshooting.

What is the FSCG of the NSN 5925-01-519-1313?
The FSCG of the NSN 5925-01-519-1313 is 5925
Does the NSN 5925-01-519-1313 have a Schedule B code assigned?
Yes, the Schedule B code is 8536200040
Does NSN 5925-01-519-1313 require demilitarization?
Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.
Does NSN 5925-01-519-1313 contain precious materials?
Item does not contain precious metal.
Does NSN 5925-01-519-1313 contain hazardous materials?
Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
When the NSN 5925-01-519-1313 was assigned to the Federal Catalog?
It was assigned 22 years ago, on Wed, Apr 7, 2004

Professional Distribution

Certified to meet the strict requirements of defense, aerospace, and hazardous materials distribution.

  • ITAR Registered
  • DDTC Registered
  • HAZMAT Certified
  • AS9120 Quality Standards
  • 100% Quality Inspections

You May Also Like

Browse other in-demand NSN parts sourced by professionals in defense, aerospace, and manufacturing sectors. Each component meets strict standards for quality and performance.

Pricing

Submit your request below and our team will respond quickly with up-to-date pricing, delivery estimates, and stock information:

ITAR Registered

Featured Parts

Explore our most requested parts, carefully selected based on customer demand and sourcing activity. Each listing provides current specifications, availability status, and item condition:

RNC60J1872DR
5905-01-092-1553
Film Fixed Resistor
RNC60J1872DS
5905-01-092-1553
Film Fixed Resistor
RNC60J1872FM
5905-00-432-5848
Film Fixed Resistor
RNC60J1872FP
5905-00-432-5848
Film Fixed Resistor
RNC60J1872FR
5905-00-432-5848
Film Fixed Resistor
RNC60J1872FS
5905-00-432-5848
Film Fixed Resistor
RNC60J1873BM
5905-00-284-6252
Film Fixed Resistor
RNC60J1873BS
5905-00-284-6252
Film Fixed Resistor
RNC60J1873FS
5905-01-040-7168
Film Fixed Resistor
RNC60J1874FM
5905-01-042-0057
Film Fixed Resistor
RNC60J1874FS
5905-01-042-0057
Film Fixed Resistor
RNC60J1892BS
5905-00-001-7333
Film Fixed Resistor
RNC60J1902BS
5905-00-273-9783
Film Fixed Resistor
RNC60J1910BS
5905-01-016-1061
Film Fixed Resistor
RNC60J1911BM
5905-00-429-5904
Film Fixed Resistor