1. Home /
  2. Catalog /
  3. Circuit Breakers /
  4. 5925-01-501-6465

5925-01-501-6465

Find complete technical information, availability, and procurement data for: 5925-01-501-6465

DODParts.com distributes related products varnishes dopes paints, aircraft parts and consumables, electrical parts, fittings and other components for the aerospace and defense industries. Submit the short price quote form for NSN 5925-01-501-6465 to receive an up to date pricing and availability quote by email.

5925-01-501-6465
Federal Supply Group
Electrical and Electronic Equipment Components
Federal Supply Classification
5925 Circuit Breakers
National Stock Number
5925-01-501-6465
Item Name Code
00136
Assigment Date
10/09/2002 (23 years ago)

2.060 inches nominal distance between centerlines of mounting facilities parallel to body length, 2.490 inches nominal body length, 1.940 inches nominal center to center distance between terminals parallel to length, single pole type body style, 0.750 inches nominal body width

Product Characteristics

Below you’ll find the complete technical specifications and performance data for this part, including material details and compliance information.

Body Style
single pole type
Body Length
2.490 inches nominal
Body Width
0.750 inches nominal
Center To Center Distance Between Terminals Parallel To Length
1.940 inches nominal
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
2.060 inches nominal
End Item Identification
5895-01-467-7213
Mounting Surface To Terminal End Distance
1.894 inches nominal
Pole Quantity
1
Mounting Facility Type And Quantity
2 threaded stud
Maximum Continuous Load Current Rating Per Pole
5.0 amperes ac single location
Operating Voltage Type And Rating Per Pole In Volts
80.0 dc single location
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
1000.0 ac all locations
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
1000.0 ac single location
Circuit Protection Type
overcurrent all locations
Circuit Protection Type
overcurrent single location
Trip Release Method
thermal-magnetic all locations
Trip Release Method
thermal-magnetic single location
Trip Release Characteristic
time delay all locations
Trip Release Characteristic
time delay single location
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 all locations
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 single location
Reset Method
manual
Main Contact Tripping Mechanism Type
trip free
Nominal Thread Size
0.190 inches
Trip Delay Time In Seconds Per Rated Continuous Current
53.000 nominal at 125 pct single location
Trip Release Ambient Temp Rating
70.0 celsius nominal all locations
Trip Release Ambient Temp Rating
70.0 celsius nominal single location
Frequency In Hertz
60.0 all locations
Frequency In Hertz
60.0 single location
Thread Series Designator
unf
Terminal Type And Quantity
2 threaded stud

Related Parts

This NSN group includes multiple components designed to meet specific performance and operational standards. Each listing provides detailed specs, functionality data, and replacement compatibility information:

Part Number Name
99002A8046-23 Circuit Breaker
IELK1-30372-23 Circuit Breaker

FAQs

Find helpful answers about installation, operation, maintenance, compliance, and troubleshooting.

What is the FSCG of the NSN 5925-01-501-6465?
The FSCG of the NSN 5925-01-501-6465 is 5925
Does the NSN 5925-01-501-6465 have a Schedule B code assigned?
Yes, the Schedule B code is 8536200040
Does NSN 5925-01-501-6465 require demilitarization?
Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.
Does NSN 5925-01-501-6465 contain precious materials?
Item does not contain precious metal.
Does NSN 5925-01-501-6465 contain hazardous materials?
Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
When the NSN 5925-01-501-6465 was assigned to the Federal Catalog?
It was assigned 23 years ago, on Wed, Oct 9, 2002

Professional Distribution

Certified to meet the strict requirements of defense, aerospace, and hazardous materials distribution.

  • ITAR Registered
  • DDTC Registered
  • HAZMAT Certified
  • AS9120 Quality Standards
  • 100% Quality Inspections

You May Also Like

Browse other in-demand NSN parts sourced by professionals in defense, aerospace, and manufacturing sectors. Each component meets strict standards for quality and performance.

Pricing

Submit your request below and our team will respond quickly with up-to-date pricing, delivery estimates, and stock information:

ITAR Registered

Featured Parts

Explore our most requested parts, carefully selected based on customer demand and sourcing activity. Each listing provides current specifications, availability status, and item condition:

5191347
5995-01-166-7194
E Special Purpose Cable Assembly
5191348
5995-01-166-7193
E Special Purpose Cable Assembly
5191349
6150-01-159-9502
Electr Lead and Conduit Assembly
519135
5330-00-923-3911
Plain Seal
519135-2
6350-01-306-9474
Pan Head Assembly
5191350
6150-01-157-6107
Elect Cable and Conduit Assembly
5191351
6150-01-154-7263
Electr Lead and Conduit Assembly
5191352
5995-01-211-8688
E Special Purpose Cable Assembly
5191353
5999-01-365-5449
Electrical-Electronic Heat Sink
5191364
5999-01-365-5450
Electrical-Electronic Heat Sink
5191366
3120-01-228-4164
Thrust Washer Bearing
5191366-2
3120-01-228-4165
Thrust Washer Bearing
5191369
3120-01-322-0890
Thrust Washer Bearing
5191370
5315-01-266-4817
Quick Release Pin
5191371
5305-00-841-2680
Shoulder Screw