5925-01-501-6457
Find complete technical information, availability, and procurement data for: 5925-01-501-6457
DODParts.com distributes related products varnishes dopes paints, aircraft parts and consumables, electrical parts, fittings and other components for the aerospace and defense industries. Submit the short price quote form for NSN 5925-01-501-6457 to receive an up to date pricing and availability quote by email.
A valve designed to automatically release excessive pressures. It is actuated by static pressure upstream of the valve and is used as a safety valve or relief valve, and may be set to close at a predetermined pressure. It is not designed for regulation of continuously fluctuating loads. It may be inline or cartridge (manifold) design. Excludes:valve (1), relief, pressure and temperature.
1.940 inches nominal center to center distance between terminals parallel to length, 2.490 inches nominal body width, 3.015 inches nominal body length, multipole-multiple actuator type body style, 0.750 inches nominal center to center distance between terminals parallel to width
Product Characteristics
Below you’ll find the complete technical specifications and performance data for this part, including material details and compliance information.
- Body Style
- multipole-multiple actuator type
- Body Length
- 3.015 inches nominal
- Body Width
- 2.490 inches nominal
- Center To Center Distance Between Terminals Parallel To Length
- 1.940 inches nominal
- Center To Center Distance Between Terminals Parallel To Width
- 0.750 inches nominal
- Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
- 2.250 inches nominal
- Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
- 0.750 inches nominal
- End Item Identification
- 5895-01-467-7213
- Boss Height
- 1.042 inches nominal
- Mounting Surface To Terminal End Distance
- 2.529 inches nominal
- Pole Quantity
- 4
- Mounting Facility Type And Quantity
- 6 threaded stud
- Maximum Continuous Load Current Rating Per Pole
- 120.0 milliamperes dc fourth location
- Maximum Continuous Load Current Rating Per Pole
- 50.0 amperes ac first location
- Maximum Continuous Load Current Rating Per Pole
- 50.0 amperes ac second location
- Maximum Continuous Load Current Rating Per Pole
- 50.0 amperes ac third location
- Operating Voltage Type And Rating Per Pole In Volts
- 250.0 ac second location
- Operating Voltage Type And Rating Per Pole In Volts
- 250.0 ac third location
- Operating Voltage Type And Rating Per Pole In Volts
- 250.0 ac first location
- Operating Voltage Type And Rating Per Pole In Volts
- 28.0 dc fourth location
- Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
- 1000.0 ac all locations
- Circuit Protection Type
- overcurrent all locations
- Trip Release Method
- thermal-magnetic all locations
- Trip Release Characteristic
- time delay all locations
- Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
- 125.0 all locations
- Reset Method
- manual
- Main Contact Tripping Mechanism Type
- trip free
- Nominal Thread Size
- 0.138 inches
- Trip Delay Time In Seconds Per Rated Continuous Current
- 0.000 nominal at 125 pct fourth location
- Trip Delay Time In Seconds Per Rated Continuous Current
- 63.000 nominal at 125 pct first location
- Trip Delay Time In Seconds Per Rated Continuous Current
- 63.000 nominal at 125 pct second location
- Trip Delay Time In Seconds Per Rated Continuous Current
- 63.000 nominal at 125 pct third location
- Trip Release Ambient Temp Rating
- 70.0 celsius nominal all locations
- Special Features
- 1st pole has single pole double throw auxiliary switch
- Frequency In Hertz
- 60.0 all locations
- Thread Series Designator
- unc
- Terminal Type And Quantity
- 6 threaded stud
Related Parts
This NSN group includes multiple components designed to meet specific performance and operational standards. Each listing provides detailed specs, functionality data, and replacement compatibility information:
| Part Number | Name |
|---|---|
| 99002A8046-22 | Circuit Breaker |
| IULHK1119-1REC4-30372-22 | Circuit Breaker |
FAQs
Find helpful answers about installation, operation, maintenance, compliance, and troubleshooting.
What is the FSCG of the NSN 5925-01-501-6457?
Does the NSN 5925-01-501-6457 have a Schedule B code assigned?
Does NSN 5925-01-501-6457 require demilitarization?
Does NSN 5925-01-501-6457 contain precious materials?
Does NSN 5925-01-501-6457 contain hazardous materials?
When the NSN 5925-01-501-6457 was assigned to the Federal Catalog?
Professional Distribution
Certified to meet the strict requirements of defense, aerospace, and hazardous materials distribution.
- ITAR Registered
- DDTC Registered
- HAZMAT Certified
- AS9120 Quality Standards
- 100% Quality Inspections
You May Also Like
Browse other in-demand NSN parts sourced by professionals in defense, aerospace, and manufacturing sectors. Each component meets strict standards for quality and performance.
Pricing
Submit your request below and our team will respond quickly with up-to-date pricing, delivery estimates, and stock information: