1. Home /
  2. Catalog /
  3. Circuit Breakers /
  4. 5925-01-497-6788

5925-01-497-6788

Find complete technical information, availability, and procurement data for: 5925-01-497-6788

DODParts.com distributes related products varnishes dopes paints, aircraft parts and consumables, electrical parts, fittings and other components for the aerospace and defense industries. Submit the short price quote form for NSN 5925-01-497-6788 to receive an up to date pricing and availability quote by email.

5925-01-497-6788
Federal Supply Group
Electrical and Electronic Equipment Components
Federal Supply Classification
5925 Circuit Breakers
National Stock Number
5925-01-497-6788
Item Name Code
00136
Assigment Date
05/30/2002 (24 years ago)

A flexible connection designed for nonvehicular applications which permits rotary motion to be transmitted between two shafts located at an angle to each other. The angle between the shafts may be continually varied within certain limits; the connecting ends must have either a flange, hub, or splined stub shaft; the plain portion of a splined stub shaft must not exceed the length of the splines. Excludes:drive or propeller shafts with joint(s) at one or both ends. See universal joint,geared.

single pole type body style, 0.580 inches maximum body width, 0.593 inches nominal center to center distance between terminals parallel to length, 0.780 inches maximum body length, 0.359 inches nominal bushing length

Product Characteristics

Below you’ll find the complete technical specifications and performance data for this part, including material details and compliance information.

Body Style
single pole type
Bushing Length
0.359 inches nominal
Body Length
0.780 inches maximum
Body Width
0.580 inches maximum
Center To Center Distance Between Terminals Parallel To Length
0.593 inches nominal
Mounting Surface To Terminal End Distance
1.420 inches maximum
Pole Quantity
1
Mounting Facility Type And Quantity
1 threaded bushing w/panel seal
Thread Quantity Per Inch
32
Maximum Continuous Load Current Rating Per Pole
5.0 amperes ac and 5.0 amperes dc single location
Operating Voltage Type And Rating Per Pole In Volts
200.0 ac and 28.0 dc single location
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
800.0 ac and 800.0 dc single location
Circuit Protection Type
overcurrent single location
Trip Release Method
thermal single location
Trip Release Characteristic
time delay single location
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
145.0 single location
Reset Method
manual
Main Contact Tripping Mechanism Type
trip free
Manual Actuator Type And Quantity
1 push-pull
Actuator Function
trip-reset
Actuator Position Designation
at pole one
Internal Trip Release Configuration
series trip single location
Nominal Thread Size
0.438 inches
Trip Delay Time In Seconds Per Rated Continuous Current
2.000 minimum at 200 pct and 20.000 maximum at 200 pct single location
Inclosure Protection Type For Which Designed
explosion resistant and moisture resistant
Trip Release Ambient Temp Rating
25.0 celsius nominal single location
Frequency In Hertz
400.0 single location
Thread Series Designator
un
Terminal Type And Quantity
2 tab w/screw

FAQs

Find helpful answers about installation, operation, maintenance, compliance, and troubleshooting.

What is the FSCG of the NSN 5925-01-497-6788?
The FSCG of the NSN 5925-01-497-6788 is 5925
Does the NSN 5925-01-497-6788 have a Schedule B code assigned?
Yes, the Schedule B code is 8536200040
Does NSN 5925-01-497-6788 require demilitarization?
Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.
Does NSN 5925-01-497-6788 contain precious materials?
Item does not contain precious metal.
Does NSN 5925-01-497-6788 contain hazardous materials?
Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
When the NSN 5925-01-497-6788 was assigned to the Federal Catalog?
It was assigned 24 years ago, on Thu, May 30, 2002

Professional Distribution

Certified to meet the strict requirements of defense, aerospace, and hazardous materials distribution.

  • ITAR Registered
  • DDTC Registered
  • HAZMAT Certified
  • AS9120 Quality Standards
  • 100% Quality Inspections

You May Also Like

Browse other in-demand NSN parts sourced by professionals in defense, aerospace, and manufacturing sectors. Each component meets strict standards for quality and performance.

Pricing

Submit your request below and our team will respond quickly with up-to-date pricing, delivery estimates, and stock information:

ITAR Registered

Featured Parts

Explore our most requested parts, carefully selected based on customer demand and sourcing activity. Each listing provides current specifications, availability status, and item condition:

255-322
5975-00-926-7416
Cable Strain Relief Bushing
255-324ECEC7JBA
6625-01-226-3504
Ammeter
255-32SEL
3020-00-051-5469
Spur Gear
255-3447
2805-01-523-8502
Exhaust Manifold
255-3480-803A
3040-01-389-0424
Mechanical Drive Housing
255-35
5310-01-040-4040
Flat Washer
255-350-ANAN
6625-01-447-6099
Electrical Frequency Meter
255-350-DNDN
6625-01-309-6770
Electrical Frequency Meter
255-3527-837A
3040-01-389-0424
Mechanical Drive Housing
255-3531-002A
3010-01-389-0420
Speed Decreaser Gear Assembly
255-3544-ND
5930-01-683-9641
Sensitive Switch
255-37
6810-00-281-4271
Bromothymol Blue Solution
255-391
5305-00-933-4181
Externally Relieved Body Screw
255-3972
6625-01-406-0277
Test Lead
255-4
5996-01-009-6445
Audio Frequency Amplifier