Find complete technical information, availability, and procurement data for: 5925-01-446-4790

DODParts.com distributes related products varnishes dopes paints, aircraft parts and consumables, electrical parts, fittings and other components for the aerospace and defense industries. Submit the short price quote form for NSN 5925-01-446-4790 to receive an up to date pricing and availability quote by email.

5925-01-446-4790
Federal Supply Group
Electrical and Electronic Equipment Components
Federal Supply Classification
5925 Circuit Breakers
National Stock Number
5925-01-446-4790
Item Name Code
00136
Assigment Date
07/03/1997 (29 years ago)

0.680 inches nominal body width, 1.125 inches nominal center to center distance between terminals parallel to length, 0.400 inches nominal bushing length, single pole type body style, 1.375 inches nominal body length

Product Characteristics

Below you’ll find the complete technical specifications and performance data for this part, including material details and compliance information.

Body Style
single pole type
Bushing Length
0.400 inches nominal
Body Length
1.375 inches nominal
Body Width
0.680 inches nominal
Center To Center Distance Between Terminals Parallel To Length
1.125 inches nominal
Switch Contact Arrangement
single pole, single throw, normally closed
End Item Identification
f-15i lantirn
Mounting Surface To Terminal End Distance
1.960 inches nominal
Pole Quantity
1
Mounting Facility Type And Quantity
1 threaded bushing
Thread Quantity Per Inch
32
Maximum Continuous Load Current Rating Per Pole
4.0 amperes ac single location
Operating Voltage Type And Rating Per Pole In Volts
250.0 ac and 50.0 dc single location
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
36.0 ac single location
Circuit Protection Type
overcurrent single location
Trip Release Method
magnetic single location
Trip Release Characteristic
time delay single location
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
135.0 single location
Ultimate Trip Time Per Pole In Seconds
7.000 nominal single location
Reset Method
manual
Main Contact Tripping Mechanism Type
trip free
Manual Actuator Type And Quantity
1 push-pull
Actuator Function
trip-reset
Actuator Position Designation
at pole one
Auxiliary Switch Function And Quantity
1 alarm
Internal Trip Release Configuration
series trip single location
Nominal Thread Size
0.375 inches
Switch Location And Position Designation
external at pole one
Trip Delay Time In Seconds Per Rated Continuous Current
0.300 minimum at 135 pct and 7.000 maximum at 135 pct single location
Switch Terminal Type
knife blade
Switch Current Rating And Type In Amps
0.1 ac
Switch Voltage Rating And Type In Volts
32.0 ac and 32.0 dc
Frequency In Hertz
50.0 or 60.0 single location
Material
plastic case
Thread Series Designator
unef
Terminal Type And Quantity
2 tab w/screw

Related Parts

This NSN group includes multiple components designed to meet specific performance and operational standards. Each listing provides detailed specs, functionality data, and replacement compatibility information:

Part Number Name
PP16-1-4.00A-XX-S Circuit Breaker

FAQs

Find helpful answers about installation, operation, maintenance, compliance, and troubleshooting.

What is the FSCG of the NSN 5925-01-446-4790?
The FSCG of the NSN 5925-01-446-4790 is 5925
Does the NSN 5925-01-446-4790 have a Schedule B code assigned?
Yes, the Schedule B code is 8536200040
Does NSN 5925-01-446-4790 require demilitarization?
Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.
Does NSN 5925-01-446-4790 contain precious materials?
Item does not contain precious metal.
Does NSN 5925-01-446-4790 contain hazardous materials?
Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
When the NSN 5925-01-446-4790 was assigned to the Federal Catalog?
It was assigned 29 years ago, on Thu, Jul 3, 1997

Professional Distribution

Certified to meet the strict requirements of defense, aerospace, and hazardous materials distribution.

  • ITAR Registered
  • DDTC Registered
  • HAZMAT Certified
  • AS9120 Quality Standards
  • 100% Quality Inspections

You May Also Like

Browse other in-demand NSN parts sourced by professionals in defense, aerospace, and manufacturing sectors. Each component meets strict standards for quality and performance.

Pricing

Submit your request below and our team will respond quickly with up-to-date pricing, delivery estimates, and stock information:

ITAR Registered

Featured Parts

Explore our most requested parts, carefully selected based on customer demand and sourcing activity. Each listing provides current specifications, availability status, and item condition:

M1200-00089
5935-01-033-3861
Electrical Receptacle Connector
M1200-00090
5935-01-031-0233
Electrical Receptacle Connector
M1200-00091
5935-01-032-3471
Electrical Receptacle Connector
M1200-00092
5935-01-033-6549
Electrical Receptacle Connector
M1200-00093
5935-01-035-0025
Electrical Receptacle Connector
M1200-00094
5935-01-031-0232
Electrical Receptacle Connector
M1200-00095
5935-01-036-3607
Electrical Receptacle Connector
M1200-00105
5935-01-064-9180
Electrical Receptacle Connector
M1200-1.024MHZ
5955-01-474-2774
Crystal Controlled Oscillator
M1200-10.0M
5955-01-324-6239
Quartz Crystal Unit
M1200-10.368MHZ
5955-01-257-0164
Crystal Controlled Oscillator
M1200-16M
5955-01-333-6647
Crystal Controlled Oscillator
M1200-2.4576M
5955-01-367-8163
Crystal Controlled Oscillator
M1200-2.4M
5955-01-392-0901
Crystal Controlled Oscillator
M1200-20MHZ
5955-01-264-2948
Crystal Controlled Oscillator